# LinuxCNC Source Semantics Contract
This contract freezes source-derived configuration behavior for the future Web control panel. The machine-readable copy is [`coverage/linuxcnc-source-semantics-contract.json`](../coverage/linuxcnc-source-semantics-contract.json); the shared Worker/workspace implementation is [`web/workspace/linuxcnc-source-semantics.mjs`](../web/workspace/linuxcnc-source-semantics.mjs).
## Rules
- LinuxCNC AXIS reads `[DISPLAY] OPEN_FILE` as an initial UI hint. The source checks whether the selected file exists before opening it, so an empty or missing `OPEN_FILE` is `optional_missing`, not a startup resource failure.
- `[DISPLAY] INTRO_GRAPHIC` is also an optional display asset.
- Missing exact `HAL`/`HALFILE` paths are classified as `BLOCKED_HAL`; they must not be reported as generic resource failures.
- Other missing exact paths are `BLOCKED_RESOURCE`. The resolver never substitutes a same-basename file from another configuration directory.
- Parameter files and tool tables may use the existing explicit runtime-fixture policy. This is a deterministic simulation fixture, not a claim that a host file exists.
- `linuxcnc/nc_files/lathe_pawn.ngc` exists, while the path requested by `lathe_multispindle.ini` (`.../nc_files/examples/lathe_pawn.ngc`) does not. The mismatch remains an optional `OPEN_FILE` diagnostic rather than a fabricated alias.
## Control Panel Boundary
The Web control panel is projection-only. It should consume Worker configuration/session snapshots and render `state`, `status`, `diagnostics`, `resources`, `hal`, `optional_missing`, `runtime_fixtures`, and `state_hash`. It must not infer readiness from file basenames, write task/motion authority, or turn `BLOCKED_*` into `TASK_READY`.
The startup states remain `NEW -> MOUNTED -> PARSED -> RESOLVED -> CORE_CREATED -> HAL_READY -> TASK_READY`, with `BLOCKED` as the fail-closed terminal state. The source semantics contract does not modify ABI, protocol, schema versions, context lock, or release blockers.
Source evidence: `linuxcnc/src/emc/usr_intf/axis/scripts/axis.py` around the `OPEN_FILE` startup path, `linuxcnc/src/emc/rs274ngc/rs274ngc_pre.cc` for parameter-file handling, and `linuxcnc/src/emc/task/emctask.cc` for program-prefix handling.