115 lines
3.2 KiB
Plaintext
115 lines
3.2 KiB
Plaintext
(author: Chris P)
|
|
(version: 0.1)
|
|
(date: 04/25/19)
|
|
|
|
(Probe Ridge in X Axis to find center and z 0 position)
|
|
(Start probe position is over center of stock in the X axis)
|
|
(within max z distance, ensure all settings have been)
|
|
(set properly according to help diagrams)
|
|
|
|
o<probe_ridge_x> sub
|
|
|
|
(uses NGCGUI style arg spec)
|
|
(number after "=" in comment is default value)
|
|
#<probe_tool_number> = #1 (=99)
|
|
#<max_z_distance> = #2 (=0.5000)
|
|
#<max_xy_distance> = #3 (=0.5000)
|
|
#<xy_clearance> = #4 (=0.1000)
|
|
#<z_clearance> = #5 (=0.1000)
|
|
#<step_off_width> = #6 (=0.5000)
|
|
#<extra_probe_depth> = #7 (=0.0000)
|
|
#<probe_slow_fr> = #8 (=0.0)
|
|
#<probe_fast_fr> = #9 (=10.0)
|
|
#<calibration_offset> = #10 (=0.0000)
|
|
#<x_hint> = #11 (=1.0000)
|
|
#<y_hint> = #12 (=1.0000)
|
|
#<diameter_hint> = #13 (=1.0000)
|
|
#<edge_width> = #14 (=0.5000)
|
|
#<probe_mode> = #15 (=0)
|
|
|
|
(Cancel G92 offsets)
|
|
G92.1
|
|
|
|
#<workspace_x> = #[5201 + [20 * #5220]]
|
|
#<workspace_z> = #[5203 + [20 * #5220]]
|
|
|
|
(Probe Tool Safety Check)
|
|
o<110> if [#5400 NE #<probe_tool_number>]
|
|
(MSG, Specified probe tool #<probe_tool_number> not in spindle, aborting)
|
|
o<probe_ridge_x> return
|
|
o<110> endif
|
|
|
|
(Probe Diameter)
|
|
#<probe_diameter> = #5410
|
|
|
|
(Probe Radius)
|
|
#<probe_radius> = [#<probe_diameter> / 2]
|
|
|
|
(Probe Centerline Offset)
|
|
#<probe_center_offset> = [#<probe_radius> - #<calibration_offset>]
|
|
|
|
(remove probe tip diam and cal offset from probed width calculations)
|
|
#<probe_diameter_offset> = [#<probe_diameter> - [#<calibration_offset> * 2]]
|
|
|
|
#<z_probe_stack> = [#<z_clearance> + #<probe_diameter> + #<extra_probe_depth>]
|
|
|
|
(Probe X Positioning Move, X hint/2 + Step Off Width)
|
|
G91
|
|
G0 X-[#<x_hint>/2 + #<step_off_width>]
|
|
|
|
(Probe X Positioning Move, to Probing Depth)
|
|
F[#<probe_fast_fr>]
|
|
G1 Z-[#<z_probe_stack>]
|
|
|
|
(Call sub "probe_x_plus" to Probe x+ side of Workpiece)
|
|
o<probe_x_plus> call [#1][#3][#4][#8][#9][#10]
|
|
|
|
#<x_plus_probed> = #5061
|
|
|
|
(first side Probe Completion Move to Z Clearance Plane)
|
|
G91
|
|
G0 Z[#<z_probe_stack>]
|
|
|
|
(Positioning move in X, X Hint + Step Off Width at Rapid Speed)
|
|
G0 X[#<x_hint> + #<step_off_width> + #<xy_clearance>]
|
|
|
|
(Probe X Positioning Move, to Probing Depth)
|
|
F[#<probe_fast_fr>]
|
|
G1 Z-[#<z_probe_stack>]
|
|
|
|
(Call sub "probe_x_minus" to Probe x- side of Workpiece)
|
|
o<probe_x_minus> call [#1][#3][#4][#8][#9][#10]
|
|
|
|
#<x_minus_probed> = #5061
|
|
|
|
(probed center calculation)
|
|
#<x_center_probed> = [[#<x_plus_probed> + #<x_minus_probed>] / 2]
|
|
|
|
(calculate X Width Probed)
|
|
#<raw_width> = [#<x_minus_probed> - #<x_plus_probed>]
|
|
|
|
(Completed probed width calculations)
|
|
#<x_probed_width> = [#<raw_width> - #<probe_diameter_offset>]
|
|
|
|
M68 E0 Q[#<x_probed_width>]
|
|
|
|
M68 E10 Q[#<x_center_probed>]
|
|
|
|
(Probe Completion Move to Z Clearance Plane, and X Zero)
|
|
G91
|
|
G0 Z[#<z_probe_stack>]
|
|
G90
|
|
G0 X[#<x_center_probed>]
|
|
|
|
(probe mode rules for WCO or probe position measuring only)
|
|
o<120> if [#<probe_mode> EQ 0]
|
|
(Record X Zero in selected WCO)
|
|
G10 L2 P#5220 X[#<x_center_probed> + #<workspace_x>]
|
|
o<probe_ridge_x> return
|
|
o<120> endif
|
|
|
|
o<probe_ridge_x> endsub
|
|
|
|