Files
2026-08-20 06:17:39 +08:00

186 lines
6.8 KiB
Plaintext

# 5i20 config file for Smithy 924 Lathe
# load the hostmot2 driver, this doesn't do anything by itself,
# it just waits for low-level drivers to register boards
loadrt hostmot2 debug_idrom=1 debug_module_descriptors=1 debug_pin_descriptors=1 debug_modules=1
# load the low-level driver for the board
# this will load the board's firmware and register it with the hostmot2
# driver loaded above, and it'll show up in HAL
loadrt hm2_pci config="firmware=hm2/5i20/SVST2_4_7I47.BIT num_encoders=3 num_pwmgens=1 num_stepgens=2"
# set up the watchdog
#setp hm2_5i20.0.watchdog.timeout_ns 10000000
# load kinematics
loadrt [KINS]KINEMATICS
# load motion controller, get name and thread periods from ini file
loadrt [EMCMOT]EMCMOT base_period_nsec=[EMCMOT]BASE_PERIOD servo_period_nsec=[EMCMOT]SERVO_PERIOD traj_period_nsec=[EMCMOT]TRAJ_PERIOD key=[EMCMOT]SHMEM_KEY num_joints=[KINS]JOINTS
# classicladder for machine logic
# (load the realtime portion)
loadrt classicladder_rt
# invoke the user part of CL to silently load the program
loadusr -w classicladder --nogui 924.clp
# load charge pump
loadrt charge_pump
# load the spindle speed lowpass filter
loadrt lowpass
#the Enable signal is used to permanently enable things
newsig Enable bit
sets Enable TRUE
#configure the spindle encoder
setp hm2_5i20.0.encoder.00.scale 4096
net Spos hm2_5i20.0.encoder.00.position spindle.0.revs
net Svel hm2_5i20.0.encoder.00.velocity spindle.0.speed-in
net Sidx hm2_5i20.0.encoder.00.index-enable => spindle.0.index-enable
#configure the spindle speed lowpass filter & PWM generator
net Scmd spindle.0.speed-out => lowpass.0.in
net Sflt lowpass.0.out => hm2_5i20.0.pwmgen.00.value
#early production machines
setp lowpass.0.gain 0.0001
#later production machines
#setp lowpass.0.gain 1.0
setp hm2_5i20.0.pwmgen.00.scale 3000
setp hm2_5i20.0.pwmgen.00.output-type 1
setp hm2_5i20.0.pwmgen.pwm_frequency 100
# invert the step pulse polarity
setp hm2_5i20.0.gpio.000.invert_output TRUE
setp hm2_5i20.0.gpio.002.invert_output TRUE
# configure the stepgen parameters
setp hm2_5i20.0.stepgen.00.dirsetup 2500
setp hm2_5i20.0.stepgen.00.dirhold 2500
setp hm2_5i20.0.stepgen.00.steplen 2500
setp hm2_5i20.0.stepgen.00.stepspace 2500
setp hm2_5i20.0.stepgen.00.position-scale [JOINT_0]SCALE
setp hm2_5i20.0.stepgen.00.maxaccel [JOINT_0]STEPGEN_MAXACCEL
setp hm2_5i20.0.stepgen.00.maxvel [JOINT_0]STEPGEN_MAXVEL
setp hm2_5i20.0.stepgen.01.dirsetup 2500
setp hm2_5i20.0.stepgen.01.dirhold 2500
setp hm2_5i20.0.stepgen.01.steplen 2500
setp hm2_5i20.0.stepgen.01.stepspace 2500
setp hm2_5i20.0.stepgen.01.position-scale [JOINT_2]SCALE
setp hm2_5i20.0.stepgen.01.maxaccel [JOINT_2]STEPGEN_MAXACCEL
setp hm2_5i20.0.stepgen.01.maxvel [JOINT_2]STEPGEN_MAXVEL
# connect position commands from motion module to step generator
net Xpos-cmd joint.0.motor-pos-cmd => hm2_5i20.0.stepgen.00.position-cmd
net Zpos-cmd joint.2.motor-pos-cmd => hm2_5i20.0.stepgen.01.position-cmd
# connect position feedback from step generators to motion module
net Xpos-fb hm2_5i20.0.stepgen.00.position-fb => joint.0.motor-pos-fb
net Zpos-fb hm2_5i20.0.stepgen.01.position-fb => joint.2.motor-pos-fb
# connect enable signals for step generators
net Xen joint.0.amp-enable-out => hm2_5i20.0.stepgen.00.enable
net Zen joint.2.amp-enable-out => hm2_5i20.0.stepgen.01.enable
# enable velocity mode jogging
net Enable joint.0.jog-vel-mode
net Enable joint.2.jog-vel-mode
# enable the PWM generator
net Enable => hm2_5i20.0.pwmgen.00.enable
# enable the charge pump
net Enable => charge-pump.enable
# connect the charge pump signal to an output
setp hm2_5i20.0.gpio.022.is_output TRUE
net chargepump hm2_5i20.0.gpio.022.out => charge-pump.out
# Safety Relay Monitoring Contacts
net estop-enable hm2_5i20.0.gpio.037.in => iocontrol.0.emc-enable-in
# Run Switch
net machine-on hm2_5i20.0.gpio.039.in_not => halui.machine.on
#connect limit switches to limit inputs
net Xmax hm2_5i20.0.gpio.024.in => joint.0.pos-lim-sw-in
net Xmin hm2_5i20.0.gpio.026.in => joint.0.neg-lim-sw-in
net Zmax hm2_5i20.0.gpio.028.in => joint.2.pos-lim-sw-in
net Zmin hm2_5i20.0.gpio.030.in => joint.2.neg-lim-sw-in
#connect positive limit signals to home inputs
net Xmax => joint.0.home-sw-in
net Zmax => joint.2.home-sw-in
# Main Contactors - True when both contactors are energized
net ACOK hm2_5i20.0.gpio.035.in_not
# VFD Fault Relay - True when VFD is not faulted
#net VFDOK hm2_5i20.0.gpio.031.in_not
# A Axis Home - On Sieg machines there is no VFD fault signal,
# it is used for the A axis home sensor on 4 axis machines
#net VFDOK hm2_5i20.0.gpio.031.in_not
#net AHOME hm2_5i20.0.gpio.031.in joint.3.home-sw-in
# Spindle Contactor - False when spindle contactor is energized
net SOFF hm2_5i20.0.gpio.033.in halui.program.pause motion.feed-hold
#Tool Post Control Inputs
net PrepNo iocontrol.0.tool-prep-number => classicladder.0.s32in-00
net TC iocontrol.0.tool-change => classicladder.0.in-00
net T1 hm2_5i20.0.gpio.032.in => classicladder.0.in-01
net T2 hm2_5i20.0.gpio.034.in => classicladder.0.in-02
net T3 hm2_5i20.0.gpio.036.in => classicladder.0.in-03
net T4 hm2_5i20.0.gpio.038.in => classicladder.0.in-04
net TP iocontrol.0.tool-prepare => classicladder.0.in-05
#Door Sensor
net SS hm2_5i20.0.gpio.029.in
# Output Bits
# KA1
setp hm2_5i20.0.gpio.040.is_output TRUE
setp hm2_5i20.0.gpio.040.invert_output TRUE
net KA1 spindle.0.reverse => hm2_5i20.0.gpio.040.out
# KA2
setp hm2_5i20.0.gpio.042.is_output TRUE
setp hm2_5i20.0.gpio.042.invert_output TRUE
net KA2 spindle.0.on => hm2_5i20.0.gpio.042.out
#Tool Post Control Outputs
net TD classicladder.0.out-00 => iocontrol.0.tool-changed
net TQ classicladder.0.out-03 => iocontrol.0.tool-prepared
#KA3
setp hm2_5i20.0.gpio.044.is_output TRUE
setp hm2_5i20.0.gpio.044.invert_output TRUE
net KA3 hm2_5i20.0.gpio.044.out => classicladder.0.out-01
#KA4
setp hm2_5i20.0.gpio.046.is_output TRUE
setp hm2_5i20.0.gpio.046.invert_output TRUE
net KA4 hm2_5i20.0.gpio.046.out => classicladder.0.out-02
#Spindle Enable
setp hm2_5i20.0.gpio.041.is_output TRUE
setp hm2_5i20.0.gpio.041.invert_output TRUE
net Enable => hm2_5i20.0.gpio.041.out
# Flood Coolant
setp hm2_5i20.0.gpio.043.is_output TRUE
setp hm2_5i20.0.gpio.043.invert_output TRUE
net M8 hm2_5i20.0.gpio.043.out => iocontrol.0.coolant-flood
# Mist Coolant
setp hm2_5i20.0.gpio.045.is_output TRUE
setp hm2_5i20.0.gpio.045.invert_output TRUE
net M7 hm2_5i20.0.gpio.045.out => iocontrol.0.coolant-mist
# hook the functions to threads
# read inputs
addf hm2_5i20.0.read servo-thread
# handle motion commands
addf motion-command-handler servo-thread
# run the motion controller
addf motion-controller servo-thread
# refresh classicladder
addf classicladder.0.refresh servo-thread
# run the spindle speed lowpass filter
addf lowpass.0 servo-thread
# write outputs
addf hm2_5i20.0.write servo-thread
# toggle the charge pump
addf charge-pump servo-thread