180 lines
7.2 KiB
Plaintext
180 lines
7.2 KiB
Plaintext
# 5i20 config file for 4 Axis Smithy 622 Mill
|
|
|
|
# load the hostmot2 driver, this doesn't do anything by itself,
|
|
# it just waits for low-level drivers to register boards
|
|
loadrt hostmot2 debug_idrom=1 debug_module_descriptors=1 debug_pin_descriptors=1 debug_modules=1
|
|
|
|
# load the low-level driver for the board
|
|
# this will load the board's firmware and register it with the hostmot2
|
|
# driver loaded above, and it'll show up in HAL
|
|
loadrt hm2_pci config="firmware=hm2/5i20/SVST2_4_7I47.BIT num_encoders=1 num_pwmgens=1 num_stepgens=4"
|
|
# set up the watchdog
|
|
#setp hm2_5i20.0.watchdog.timeout_ns 10000000
|
|
|
|
# load kinematics
|
|
loadrt [KINS]KINEMATICS
|
|
|
|
# load motion controller, get name and thread periods from ini file
|
|
loadrt [EMCMOT]EMCMOT base_period_nsec=[EMCMOT]BASE_PERIOD servo_period_nsec=[EMCMOT]SERVO_PERIOD traj_period_nsec=[EMCMOT]TRAJ_PERIOD key=[EMCMOT]SHMEM_KEY num_joints=[KINS]JOINTS
|
|
|
|
# load charge pump
|
|
loadrt charge_pump
|
|
|
|
# These loopbacks are usually disconnected by a postgui halfile
|
|
net tool-change-loop iocontrol.0.tool-change iocontrol.0.tool-changed
|
|
net tool-prepare-loopback iocontrol.0.tool-prepare iocontrol.0.tool-prepared
|
|
|
|
#the Enable signal is used to permanently enable things
|
|
newsig Enable bit
|
|
sets Enable TRUE
|
|
|
|
#configure the spindle speed
|
|
net scmd spindle.0.speed-out hm2_5i20.0.pwmgen.00.value
|
|
setp hm2_5i20.0.pwmgen.00.scale 5000
|
|
setp hm2_5i20.0.pwmgen.00.output-type 1
|
|
setp hm2_5i20.0.pwmgen.pwm_frequency 100
|
|
|
|
# invert the step pulse polarity
|
|
setp hm2_5i20.0.gpio.000.invert_output TRUE
|
|
setp hm2_5i20.0.gpio.002.invert_output TRUE
|
|
setp hm2_5i20.0.gpio.016.invert_output TRUE
|
|
setp hm2_5i20.0.gpio.018.invert_output TRUE
|
|
|
|
# configure the stepgen parameters
|
|
setp hm2_5i20.0.stepgen.00.dirsetup 2500
|
|
setp hm2_5i20.0.stepgen.00.dirhold 2500
|
|
setp hm2_5i20.0.stepgen.00.steplen 2500
|
|
setp hm2_5i20.0.stepgen.00.stepspace 2500
|
|
setp hm2_5i20.0.stepgen.00.position-scale [JOINT_0]SCALE
|
|
setp hm2_5i20.0.stepgen.00.maxaccel [JOINT_0]STEPGEN_MAXACCEL
|
|
setp hm2_5i20.0.stepgen.00.maxvel [JOINT_0]STEPGEN_MAXVEL
|
|
setp hm2_5i20.0.stepgen.01.dirsetup 2500
|
|
setp hm2_5i20.0.stepgen.01.dirhold 2500
|
|
setp hm2_5i20.0.stepgen.01.steplen 2500
|
|
setp hm2_5i20.0.stepgen.01.stepspace 2500
|
|
setp hm2_5i20.0.stepgen.01.position-scale [JOINT_1]SCALE
|
|
setp hm2_5i20.0.stepgen.01.maxaccel [JOINT_1]STEPGEN_MAXACCEL
|
|
setp hm2_5i20.0.stepgen.01.maxvel [JOINT_1]STEPGEN_MAXVEL
|
|
setp hm2_5i20.0.stepgen.02.dirsetup 2500
|
|
setp hm2_5i20.0.stepgen.02.dirhold 2500
|
|
setp hm2_5i20.0.stepgen.02.steplen 2500
|
|
setp hm2_5i20.0.stepgen.02.stepspace 2500
|
|
setp hm2_5i20.0.stepgen.02.position-scale [JOINT_2]SCALE
|
|
setp hm2_5i20.0.stepgen.02.maxaccel [JOINT_2]STEPGEN_MAXACCEL
|
|
setp hm2_5i20.0.stepgen.02.maxvel [JOINT_2]STEPGEN_MAXVEL
|
|
setp hm2_5i20.0.stepgen.03.dirsetup 2500
|
|
setp hm2_5i20.0.stepgen.03.dirhold 2500
|
|
setp hm2_5i20.0.stepgen.03.steplen 2500
|
|
setp hm2_5i20.0.stepgen.03.stepspace 2500
|
|
setp hm2_5i20.0.stepgen.03.position-scale [JOINT_3]SCALE
|
|
setp hm2_5i20.0.stepgen.03.maxaccel [JOINT_3]STEPGEN_MAXACCEL
|
|
setp hm2_5i20.0.stepgen.03.maxvel [JOINT_3]STEPGEN_MAXVEL
|
|
|
|
# connect position commands from motion module to step generator
|
|
net Xpos-cmd joint.0.motor-pos-cmd => hm2_5i20.0.stepgen.00.position-cmd
|
|
net Ypos-cmd joint.1.motor-pos-cmd => hm2_5i20.0.stepgen.01.position-cmd
|
|
net Zpos-cmd joint.2.motor-pos-cmd => hm2_5i20.0.stepgen.02.position-cmd
|
|
net Apos-cmd joint.3.motor-pos-cmd => hm2_5i20.0.stepgen.03.position-cmd
|
|
|
|
# connect position feedback from step generators to motion module
|
|
net Xpos-fb hm2_5i20.0.stepgen.00.position-fb => joint.0.motor-pos-fb
|
|
net Ypos-fb hm2_5i20.0.stepgen.01.position-fb => joint.1.motor-pos-fb
|
|
net Zpos-fb hm2_5i20.0.stepgen.02.position-fb => joint.2.motor-pos-fb
|
|
net Apos-fb hm2_5i20.0.stepgen.03.position-fb => joint.3.motor-pos-fb
|
|
|
|
# connect enable signals for step generators
|
|
net Xen joint.0.amp-enable-out => hm2_5i20.0.stepgen.00.enable
|
|
net Yen joint.1.amp-enable-out => hm2_5i20.0.stepgen.01.enable
|
|
net Zen joint.2.amp-enable-out => hm2_5i20.0.stepgen.02.enable
|
|
net Aen joint.3.amp-enable-out => hm2_5i20.0.stepgen.03.enable
|
|
|
|
# enable velocity mode jogging
|
|
net Enable joint.0.jog-vel-mode
|
|
net Enable joint.1.jog-vel-mode
|
|
net Enable joint.2.jog-vel-mode
|
|
net Enable joint.3.jog-vel-mode
|
|
|
|
# enable the PWM generator
|
|
net Enable => hm2_5i20.0.pwmgen.00.enable
|
|
|
|
# enable the charge pump
|
|
net Enable => charge-pump.enable
|
|
|
|
# connect the charge pump signal to an output
|
|
setp hm2_5i20.0.gpio.022.is_output TRUE
|
|
net chargepump hm2_5i20.0.gpio.022.out => charge-pump.out
|
|
|
|
# Safety Relay Monitoring Contacts
|
|
net estop-enable hm2_5i20.0.gpio.037.in => iocontrol.0.emc-enable-in
|
|
# Run Switch
|
|
net machine-on hm2_5i20.0.gpio.039.in_not => halui.machine.on
|
|
|
|
#connect limit switches to limit inputs
|
|
net Xmax hm2_5i20.0.gpio.032.in => joint.0.pos-lim-sw-in
|
|
net Xmin hm2_5i20.0.gpio.034.in => joint.0.neg-lim-sw-in
|
|
net Ymax hm2_5i20.0.gpio.028.in => joint.1.pos-lim-sw-in
|
|
net Ymin hm2_5i20.0.gpio.030.in => joint.1.neg-lim-sw-in
|
|
net Zmax hm2_5i20.0.gpio.024.in => joint.2.pos-lim-sw-in
|
|
net Zmin hm2_5i20.0.gpio.026.in => joint.2.neg-lim-sw-in
|
|
|
|
#connect positive limit signals to home inputs
|
|
net Xmax => joint.0.home-sw-in
|
|
net Ymax => joint.1.home-sw-in
|
|
net Zmax => joint.2.home-sw-in
|
|
|
|
# Spindle Contactor Enable
|
|
setp hm2_5i20.0.gpio.041.is_output TRUE
|
|
setp hm2_5i20.0.gpio.041.invert_output TRUE
|
|
# Door Closed - Energizes spindle contactor
|
|
net CLOSED hm2_5i20.0.gpio.029.in_not hm2_5i20.0.gpio.041.out
|
|
|
|
# Main Contactors - True when both contactors are energized
|
|
net ACOK hm2_5i20.0.gpio.035.in_not
|
|
# VFD Fault Relay - True when VFD is not faulted
|
|
#net VFDOK hm2_5i20.0.gpio.031.in_not
|
|
# A Axis Home - On Sieg machines there is no VFD fault signal,
|
|
# it is used for the A axis home sensor on 4 axis machines
|
|
#net VFDOK hm2_5i20.0.gpio.031.in_not
|
|
net AHOME hm2_5i20.0.gpio.031.in joint.3.home-sw-in
|
|
# Spindle Contactor - False when spindle contactor is energized
|
|
net SOFF hm2_5i20.0.gpio.033.in halui.program.pause motion.feed-hold
|
|
|
|
# Axis Drive Status Signals
|
|
# True when YAKO stepper drive is on a full step position
|
|
# True when a Leadshine stepper drive is in the READY state
|
|
net DRV1 hm2_5i20.0.gpio.025.in_not
|
|
net DRV2 hm2_5i20.0.gpio.036.in_not
|
|
net DRV3 hm2_5i20.0.gpio.027.in_not
|
|
net DRV4 hm2_5i20.0.gpio.038.in_not
|
|
|
|
# Output Bits
|
|
# KA1
|
|
setp hm2_5i20.0.gpio.040.is_output TRUE
|
|
setp hm2_5i20.0.gpio.040.invert_output TRUE
|
|
net KA1 spindle.0.reverse => hm2_5i20.0.gpio.040.out
|
|
# KA2
|
|
setp hm2_5i20.0.gpio.042.is_output TRUE
|
|
setp hm2_5i20.0.gpio.042.invert_output TRUE
|
|
net KA2 spindle.0.on => hm2_5i20.0.gpio.042.out
|
|
# Flood Coolant
|
|
setp hm2_5i20.0.gpio.043.is_output TRUE
|
|
setp hm2_5i20.0.gpio.043.invert_output TRUE
|
|
net M8 hm2_5i20.0.gpio.043.out => iocontrol.0.coolant-flood
|
|
# Mist Coolant
|
|
setp hm2_5i20.0.gpio.045.is_output TRUE
|
|
setp hm2_5i20.0.gpio.045.invert_output TRUE
|
|
net M7 hm2_5i20.0.gpio.045.out => iocontrol.0.coolant-mist
|
|
|
|
# hook the functions to threads
|
|
# read inputs
|
|
addf hm2_5i20.0.read servo-thread
|
|
# handle motion commands
|
|
addf motion-command-handler servo-thread
|
|
# run the motion controller
|
|
addf motion-controller servo-thread
|
|
# write outputs
|
|
addf hm2_5i20.0.write servo-thread
|
|
# toggle the charge pump
|
|
addf charge-pump servo-thread
|
|
|