# for each click of the jog-wheel there's 1000 simulated counts coming out
# of the ilowpass below, so these numbers are 1000x smaller than the jog
# increment size they encode
setp tristate-float.sxp-jog-increment-0.in 0.0005
setp tristate-float.sxp-jog-increment-1.in 0.001
setp tristate-float.sxp-jog-increment-2.in 0.005
setp tristate-float.sxp-jog-increment-3.in 0.010
# each of the 8 tristate floats has a constant jog speed on it
# speeds are specified as "fraction of machine max speed"
setp tristate-float.sxp0.in 0
setp tristate-float.sxp1.in 25
setp tristate-float.sxp2.in 50
setp tristate-float.sxp3.in 100
setp tristate-float.sxp4.in 200
setp tristate-float.sxp5.in 400
setp tristate-float.sxp6.in 810
setp tristate-float.sxp7.in 1620