Gecko_540B3 configuration for a 3 axis machine with X Y Z axes.
|
|
|
|
To use the charge pump on a G540 your base period must be set to 50,000 or lower. Otherwise disable the charge pump feature.
|
|
|
|
The Stepconf Wizard XML file is included so you can open it up and customize the configuration to suit your machine. After installing this configuration move the Gecko_540B3.stepconf file to the configs directory, then run the Stepconf Wizard and select Modify a configuration already created with this program.
|
|
|
|
Run the latency test to determine your max jitter and enter that in the Stepconf Wizard.
|
|
|
|
Set the axis limits, gearing for each axis.
|
|
|
|
Customize as needed to suit your machine.
|
|
|