wangdequan 9a7c4f0335 Save FreeCAD Web workspace sources and user validation evidence
IFC native binding remains incomplete; preserve accurate test results.
2026-09-15 22:01:58 +08:00

72 lines
3.5 KiB
Markdown

# Website Owner Routing Correction
Eight commands wired and built: Std_DevHandbook, Std_FreeCADDonation,
Std_FreeCADForum, Std_FreeCADUserHub, Std_FreeCADWebsite, Std_OnlineHelp,
Std_OnlineHelpWebsite, Std_ReportBug. Receipt: web-website-owner-pipeline.json,
eight ready and zero missing. No automatic tests, browser checks, acceptance,
benchmarks or visits to these websites were run.
## Corrected False Completion
The preceding browser-help change added fourteen catalog entries but only
looked for a matching property name and a window.open string in the adapter.
It did not establish that control flow reached that branch. Earlier native
branches returned before the browser code. Recent files/macros, text documents,
unit calculator and other GUI workflows were incorrectly included as well.
Removed browserCommands discovery and the overly broad catalog. Their original
source implementations, records and history remain. The new websiteCommands
catalog contains eight explicit URL workflows; it is consumed by the actual
early adapter, capability generator and owner-specific build packet.
## Actual Business Path
WebWebsiteTask -> executeWebDesktop -> executeWebsite -> existing Part owner
endpoint -> nativeDocumentView -> existing WebViewCommands website logic.
The local CommandStd.cpp reads the Websites parameter group for configured
URLs. The native implementation preserves that behavior instead of forcing a
frontend URL constant. Online Help resolves the documentation start page.
The selected PartBox or DocumentProbe owner remains explicit; no document is
fabricated and no pointers cross WASM runtimes.
The adapter now returns the owner-bound batch envelope used by the UI rather
than a raw result. The mounted task requires matching owner, document, command,
canonical ID and success status before showing the link. It accepts HTTP(S)
destinations without embedded credentials. Async native calls do not attempt a
popup: a real anchor gives the user a direct open action. Old duplicate website
and Python-console surfaces are not mounted for this group.
Other records need their own implementation and are not promoted by merely
appearing in a URL/action table. No native markers or new worker were added.
## Build Accounting
| Step | Seconds |
| --- | ---: |
| Initial capability generation | 8.580 |
| Both existing owner target builds | 60.880 |
| Implementation packet preparation | 1.972 |
| Formal handoff pipeline | 12.810 |
| Pipeline capability generation | 8.724 |
| Pipeline build dependency check | 0.202 |
| Pipeline artifact synchronization | 2.721 |
| Frontend build | 4.090 |
| Public asset sync inside frontend build | 2.551 |
Both native targets had older artifacts than their existing native headers;
the build published those current inputs and exited 0. Unchanged FreeCAD/OCCT
dependencies were reused. Final pipeline build only generated the version file,
without another compile/link. Frontend build exited 0. No runtime parity is
inferred from successful compilation.
## Progress and Remaining Scope
Corrected inventory: 1355/1451 routed, 96 requiring implementation. The decrease
from the previously reported 1361 is a correction of false route accounting.
This is not deletion of user functionality and not a user-verified completion
percentage. Full help viewer/search/offline packages and the non-URL commands
formerly swept into browserCommands remain separate work. Scheduler was still
running with a waiting_for_retry state at the final snapshot; throughput recovery
is not claimed. Reuse this handler and receipt for the website group.