# BIM STEP import recovery boundary
|
|
|
|
Batch: `941fac2e6c3a20041edef8f2`
|
|
Selected business: `business-format:BIM:import:.stp`.
|
|
|
|
The supplied failure reports a WASM memory access trap during document inspection
|
|
after STEP input rejection. It does not identify the native faulting symbol or
|
|
prove whether missing or malformed input caused the preceding rejection.
|
|
|
|
The BIM STEP workflow now wraps native `Part.insert`, shape validation and
|
|
recompute in a FreeCAD document transaction. Failed import or validation aborts
|
|
the transaction instead of retaining partially imported objects. Geometry still
|
|
comes from the existing Part/OCCT reader. The business case now names missing
|
|
and malformed rejection and subsequent inspection stages separately; all geometry,
|
|
document preservation and recovery assertions remain required.
|
|
|
|
This fixes the visible rollback gap but does not establish the cause or resolution
|
|
of the memory trap. Build, sync and business acceptance are owned by the outer
|
|
pipeline and were not run in this edit turn. Rebuild the affected
|
|
`FreeCADWebBimRuntimeProbe` target and run the selected STEP business case. If the
|
|
trap remains, retain the newly distinguished failing stage and resolve the WASM
|
|
stack to native symbols before further changes. No business acceptance is claimed.
|