using MesControl;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Xml.Linq;
//using SystemFramework;
namespace MisDataName
{
public delegate void ControlConnectPLC();
public partial class SecondForm
{
ControlConnectPLC PlcConnectTimer;
void InitFormDynamicControls()
{
try
{
// DataTable dt_OpName=(DataTable) FunctionForm_HashiTable.OpName_Hash_Read("OpNameList");
List<MesBoolSignal> signalItems = InitWorkStationSignal();
RecordWorkStationSignal(signalItems);
int RowsWidth = SignalPanel.Width-20;
int RowsNum = RowsWidth / 133;
int i = 0;
var opNameList = MIS_BASE.Get_opNameList();
foreach (var opName in opNameList)
{
PlcWorkStationSignal plcWorkStationSignal = new PlcWorkStationSignal();
plcWorkStationSignal.BackColor = System.Drawing.Color.Transparent;
plcWorkStationSignal.Location = new System.Drawing.Point(3 + ((i % RowsNum) * 133), (i / RowsNum) * ((signalItems.Count * 25) + 60));
plcWorkStationSignal.MaximumSize = new System.Drawing.Size(0, 0);
plcWorkStationSignal.MinimumSize = new System.Drawing.Size(0, 0);
plcWorkStationSignal.Name = "plcWorkStationSignal_" + opName;
plcWorkStationSignal.Size = new System.Drawing.Size(136, 60);
plcWorkStationSignal.TabIndex = i;
plcWorkStationSignal.SignalItems = signalItems;
plcWorkStationSignal.WorkStationNameText = opName;
plcWorkStationSignal.WS_PlcLabelText = "PLC连接";
plcWorkStationSignal.TestPLC_Interval = 10000;
plcWorkStationSignal.TestPLC_Enable = true;
PlcConnectTimer += plcWorkStationSignal.ExternalTimerExcute;
this.SignalPanel.Controls.Add(plcWorkStationSignal);
i++;
}
}
catch (Exception err)
{
//ApplicationLog.WriteLog(err, err.Message);
}
}
public List<MesBoolSignal> InitWorkStationSignal()
{
try
{
List<MesBoolSignal> signalItems = new List<MesBoolSignal>();
MesBoolSignal MBS;
signalItems.Clear();
XDocument SystemConfig = XDocument.Load("SystemConfig.xml");
IEnumerable<XElement> plc = SystemConfig.Descendants ("PLC");
IEnumerable<XElement> plcSignal = plc.Elements();
foreach (XElement PlcSignal in plcSignal)
{
XElement Name = PlcSignal.Element("Name");
XElement TagType = PlcSignal.Element("TagType");
XElement Text = PlcSignal.Element("Text");
XElement Index = PlcSignal.Element("Index");
XElement Enabled = PlcSignal.Element("Enabled");
MBS = new MesBoolSignal();
MBS.Name = "TagType_" + TagType.Value ;
MBS.SignalText = Text.Value ;
MBS.SignalImage = MesBoolSignal.SignalImage_Enum.none;
if (Convert.ToBoolean(Enabled.Value))
{
signalItems.Add(MBS);
}
}
IEnumerable<XElement> mes = SystemConfig.Descendants("MES");
IEnumerable<XElement> mesSignal = mes.Elements();
foreach (XElement MesSignal in mesSignal)
{
XElement Name = MesSignal.Element("Name");
XElement TagType = MesSignal.Element("TagType");
XElement Text = MesSignal.Element("Text");
XElement Index = MesSignal.Element("Index");
XElement Enabled = MesSignal.Element("Enabled");
MBS = new MesBoolSignal();
MBS.Name = "TagType_" + TagType.Value;
MBS.SignalText = Text.Value;
MBS.SignalImage = MesBoolSignal.SignalImage_Enum.none;
if (Convert .ToBoolean ( Enabled .Value))
{
signalItems.Add(MBS);
}
}
return signalItems;
}
catch (Exception err)
{
//ApplicationLog.WriteLog(err, err.Message);
return null;
}
}
string[] SignalNames;
void RecordWorkStationSignal(List<MesBoolSignal> items)
{
SignalNames = new string[items.Count];
for (int i=0;i< items.Count;i++)
{
SignalNames[i] = items[i].Name;
}
}
}
}