"schema": "freecad-web-p6-workbench-command-gate/v1",
"taskId": "FW-P6-FPA-G",
"result": "pass",
"coverage": {
"modules": 32,
"guiModules": 22,
"records": 778,
"dispositions": {
"native_handler": 138,
"restricted": 640,
"not_implemented": 0
}
},
"artifacts": {
"matrix": {
"path": "docs/p6/workbench-command-matrix.json",
"sha256": "d445dca42caf4a6597c9a4c99778d1aa4002c9f6909fd7983c4a384df3af2075"
},
"native": {
"path": "docs/p6/workbench-command-native-smoke.json",
"sha256": "50d16ec313184418c5dccc27b6151ca3e2a42d2f032167c5a346606f7f7f8131"
},
"facade": {
"path": "docs/p6/workbench-command-facade.json",
"sha256": "ba928ab5a5a45bfce184d3eeabc0d7d34b29c24e563343983df7848103b5127f"
},
"chrome": {
"path": "docs/p6/workbench-command-chrome.json",
"sha256": "7aeb90d52e09f37f7977a3312607113df1ec5a3c5a7b023fa58ae3ef40a6c063"
},
"screenshot": "FreeCAD/docs/p6/workbench-command-chrome.png",
"screenshotSha256": "4e719a42cb06645c2373fa875606abb1d115c969e32dc0ad85cd423f6a6685b7",
"wasm": {
"path": "web/public/kernel/FreeCADWebWorkbenchCommandProbe.wasm",
"sha256": "761882251cf05edf2a50c160abc95c1bf3f7dc42bc724ca1f1322ab7927fba64"
},
"javascript": {
"path": "web/public/kernel/FreeCADWebWorkbenchCommandProbe.js",
"sha256": "58ea299e346adf3979b174eeb18390c60439a0871a2749d2a284fb6cf9b882a3"
}
},
"browser": {
"version": "Google Chrome 151.0.7922.137",
"mode": "headless-new",
"viewport": {
"width": 1440,
"height": 900,
"deviceScaleFactor": 1
}
},
"cases": [
{
"id": "workbench-ready",
"status": "pass",
"stage": "ready",
"error": null
},
{
"id": "workbench-action",
"status": "pass",
"stage": "success",
"error": null
},
{
"id": "workbench-expected-error",
"status": "pass",
"stage": "expected-error",
"error": "invalid_request"
},
{
"id": "workbench-cancel",
"status": "pass",
"stage": "cancelled",
"error": "cancelled"
},
{
"id": "workbench-reset",
"status": "pass",
"stage": "reset",
"error": null
},
{
"id": "workbench-repeat",
"status": "pass",
"stage": "success",
"error": null
}
],
"boundaries": [
"Desktop Gui/Qt commands are explicit restricted records until a portable Web workflow is backed by its own native route.",
"Web command records prove registry routing and dispatcher disposition; route-specific module gates remain authoritative for command behavior.",
"Task panels and resources are inventoried and surfaced as source entries; Qt-only interaction remains a declared boundary."
]
}