Files
FreeCADWasmDev/docs/p6/part-action-05-recovery.json
wangdequan 9a7c4f0335 Save FreeCAD Web workspace sources and user validation evidence
IFC native binding remains incomplete; preserve accurate test results.
2026-09-15 22:01:58 +08:00

4 lines
882 B
JSON

{
"schema":"freecad-web-part-save-reopen-recovery/v1","task_id":"FW-P6-PRT-ACT-05-D","status":"pass","source_revision":"837f44197c879e41198b7e3bed55c897a9920520","input_sha256":"ca5a4753beb2e4fd1e404d397663bac760679be80c63c80f62f176bc7fa15488","result_sha256":"1fe02e4328f6fba6db880ed8d21ddbe6bb8405d23c08cc2a2f9be8d2eb062480","result":{"invalidError":"Length of box too small","invalidStateVolume":23.999999999999996,"recoveredVolume":23.999999999999996,"saveOpenStateUnchanged":true,"resourcesReleased":true},"artifacts":{"smoke_log":{"path":"docs/freecad-p6-part-action-05-c-document.log","sha256":"1fe02e4328f6fba6db880ed8d21ddbe6bb8405d23c08cc2a2f9be8d2eb062480"}},"boundaries":["Invalid dimension recovery is covered before save/reopen; reopened Part::Box properties remain valid.","No concurrent document mutation is claimed."],"generated_at":"2026-08-22T16:48:34+08:00"
}