增加G90G91批量fixture验证
结论:新增 modal_incremental fixture,覆盖 G90/G91 距离模式切换、G1 模态继承和回到绝对模式;验证脚本改为批量执行所有 G-code fixture 并匹配 expected canonical events。检查:git diff --check 通过;wasm-port/tests/native/verify_native_probes.sh 通过。
This commit is contained in:
5
wasm-port/tests/fixtures/canon/modal_incremental.events
vendored
Normal file
5
wasm-port/tests/fixtures/canon/modal_incremental.events
vendored
Normal file
@@ -0,0 +1,5 @@
|
||||
canon_event=STRAIGHT_TRAVERSE line=1 x=1 y=1 z=0 a=0 b=0 c=0 u=0 v=0 w=0
|
||||
canon_event=SET_FEED_RATE rate=60
|
||||
canon_event=STRAIGHT_FEED line=2 x=3 y=1 z=0 a=0 b=0 c=0 u=0 v=0 w=0
|
||||
canon_event=STRAIGHT_FEED line=3 x=3 y=4 z=0 a=0 b=0 c=0 u=0 v=0 w=0
|
||||
canon_event=STRAIGHT_TRAVERSE line=4 x=0 y=0 z=0 a=0 b=0 c=0 u=0 v=0 w=0
|
||||
Reference in New Issue