184 lines
9.4 KiB
C#
184 lines
9.4 KiB
C#
using MesServerWork;
|
||
using MisDataFunDll;
|
||
using MisDataSaveDate;
|
||
using System;
|
||
using System.Collections;
|
||
|
||
namespace MesServerFunctions
|
||
{
|
||
partial class FunctionMES
|
||
{
|
||
/// <summary>
|
||
/// 处理 PAD/MQTT 发送到 Function1062 的 WEB 命令。
|
||
/// 消息外层格式由通讯层统一为:WEB|命令|工位号|参数。
|
||
/// 命令名不增加 OP431 前缀,工位归属统一通过 opName 判断,避免同一业务出现多套命令名。
|
||
/// </summary>
|
||
private void WebSubmit(object e)
|
||
{
|
||
try
|
||
{
|
||
var msgEvent = (DeviceDriver_BasicData.CustomeEvetnArgs)e;
|
||
string opName = Convert.ToString(msgEvent.OpName);
|
||
string content = Convert.ToString(msgEvent.TagValue);
|
||
|
||
// Function 入口已将 MQTT 的 Command 和 Value 合并为“命令|参数”。
|
||
// 参数支持“产品码”或“产品码^最小静置分钟数”,订单、机型等业务信息必须由后端重新查询。
|
||
string[] dataArray = content.Split('|');
|
||
if (dataArray.Length != 2)
|
||
{
|
||
MisDataFun.LogRecording_OP(opName, "ERROR", "WEB", "PAD命令格式错误,内容:" + content);
|
||
return;
|
||
}
|
||
|
||
string command = dataArray[0].Trim();
|
||
string value = dataArray[1].Trim();
|
||
|
||
switch (command)
|
||
{
|
||
// PAD 扫码查询:只查询产品、前序离开时间和静置分钟数,不写 PLC,也不调用工厂 MES 进站。
|
||
case "PadScanQuery":
|
||
{
|
||
if (!TryGetManualStaticPadRequest(opName, "PadScanQuery", value, out string engineID, out decimal minStaticMinutes))
|
||
{
|
||
return;
|
||
}
|
||
|
||
bool success = QueryManualStaticOutProduct(opName, engineID, minStaticMinutes, out string message);
|
||
SendManualStaticOutResult(opName, "PadScanQuery", success, message);
|
||
MisDataFun.LogRecording_OP(opName, success ? "INFO" : "WARNING", "PadScanQuery", message);
|
||
break;
|
||
}
|
||
// PAD 确认上线:重新校验托盘到位、PLC申请上线和前端配置的最小静置时间,通过后写 PLC 产品区。
|
||
case "PadConfirmOnline":
|
||
{
|
||
if (!TryGetManualStaticPadRequest(opName, "PadConfirmOnline", value, out string engineID, out decimal minStaticMinutes))
|
||
{
|
||
return;
|
||
}
|
||
|
||
bool success = ConfirmManualStaticOutProduct(opName, engineID, minStaticMinutes, out string message);
|
||
SendManualStaticOutResult(opName, "PadConfirmOnline", success, message);
|
||
MisDataFun.LogRecording_OP(opName, success ? "INFO" : "ERROR", "PadConfirmOnline", message);
|
||
break;
|
||
}
|
||
// 页面刷新或 PAD 重新订阅 MQTT 后,用当前 PLC/MES 状态恢复界面显示。
|
||
case "IniSingalToWeb":
|
||
InitializeSingalToWeb(opName);
|
||
break;
|
||
default:
|
||
MisDataFun.LogRecording_OP(opName, "WARNING", "WebSubmit", "不支持的PAD命令:" + command);
|
||
break;
|
||
}
|
||
}
|
||
catch (Exception err)
|
||
{
|
||
MyLog4Net.MyLogHelper.Error("Function1062.WebSubmit", err.Message);
|
||
MisDataFun.LogRecording_OP(ManualStaticOutOpName, "ERROR", "WebSubmit", err.Message);
|
||
}
|
||
}
|
||
|
||
private bool TryGetManualStaticPadRequest(string opName, string command, string value, out string engineID, out decimal minStaticMinutes)
|
||
{
|
||
engineID = "";
|
||
minStaticMinutes = DefaultManualStaticMinutes;
|
||
string requestValue = Convert.ToString(value).Trim();
|
||
|
||
// PAD 上传产品码和可选最小静置分钟数。订单、机型、静置开始时间等信息全部从 MES 数据库重新取。
|
||
if (string.IsNullOrWhiteSpace(requestValue))
|
||
{
|
||
string message = "PAD命令参数为空,格式:" + command + "|产品码 或 " + command + "|产品码^最小静置分钟数";
|
||
SendManualStaticOutResult(opName, command, false, message);
|
||
MisDataFun.LogRecording_OP(opName, "ERROR", "WEB", message);
|
||
return false;
|
||
}
|
||
|
||
if (requestValue.Contains("&"))
|
||
{
|
||
string message = "PAD命令参数格式错误,格式:" + command + "|产品码 或 " + command + "|产品码^最小静置分钟数,收到:" + value;
|
||
SendManualStaticOutResult(opName, command, false, message);
|
||
MisDataFun.LogRecording_OP(opName, "ERROR", "WEB", message);
|
||
return false;
|
||
}
|
||
|
||
string[] requestItems = requestValue.Split('^');
|
||
if (requestItems.Length > 2)
|
||
{
|
||
string message = "PAD命令参数格式错误,格式:" + command + "|产品码 或 " + command + "|产品码^最小静置分钟数,收到:" + value;
|
||
SendManualStaticOutResult(opName, command, false, message);
|
||
MisDataFun.LogRecording_OP(opName, "ERROR", "WEB", message);
|
||
return false;
|
||
}
|
||
|
||
engineID = requestItems[0].Trim();
|
||
if (string.IsNullOrWhiteSpace(engineID))
|
||
{
|
||
string message = "PAD命令产品码为空,格式:" + command + "|产品码 或 " + command + "|产品码^最小静置分钟数";
|
||
SendManualStaticOutResult(opName, command, false, message);
|
||
MisDataFun.LogRecording_OP(opName, "ERROR", "WEB", message);
|
||
return false;
|
||
}
|
||
|
||
if (requestItems.Length == 2)
|
||
{
|
||
string minStaticMinutesText = requestItems[1].Trim();
|
||
if (!decimal.TryParse(minStaticMinutesText, out minStaticMinutes) || minStaticMinutes < 0)
|
||
{
|
||
string message = "PAD命令最小静置分钟数无效,收到:" + minStaticMinutesText;
|
||
SendManualStaticOutResult(opName, command, false, message);
|
||
MisDataFun.LogRecording_OP(opName, "ERROR", "WEB", message);
|
||
return false;
|
||
}
|
||
}
|
||
|
||
return true;
|
||
}
|
||
|
||
/// <summary>
|
||
/// 页面重新登录或 PAD 重新订阅时恢复关键状态。
|
||
/// 这里发送的是通用命令名,工位由 opName 区分。
|
||
/// </summary>
|
||
private void InitializeSingalToWeb(string opName)
|
||
{
|
||
MIS_BASE.GetEngineTypeFromDB(opName, out int engineTypeID, out string engineType, out string engineID, out int partPalletCode);
|
||
|
||
MIS_BASE.Read_WorkStart(opName, out bool workStart);
|
||
MIS_BASE.Read_PartLoad(opName, out bool partLoad);
|
||
MIS_BASE.Read_EngineGetOver_PLC(opName, out bool engineGetOver);
|
||
MIS_BASE.Read_FixAllow(opName, out bool fixAllow);
|
||
MIS_BASE.Read_QualityData_Read_CF(opName, out bool mesRead);
|
||
MIS_BASE.Read_MesReadOver(opName, out bool readOver);
|
||
MIS_BASE.Read_MaterialVerifyOver(opName, out bool workFinish);
|
||
MIS_BASE.Read_QualityMask(opName, out int qualityMask);
|
||
MIS_BASE.Read_FalseGo(opName, out bool falseGo);
|
||
|
||
if (!string.IsNullOrWhiteSpace(engineID))
|
||
{
|
||
SendMessageFun.SendMessage("5123", "1111", opName);
|
||
}
|
||
|
||
// 以下状态沿用通用 MES 页面命令,PAD 或页面通过 opName 判断属于哪个工位。
|
||
SendMessageFun.SendInfomation("WorkStart", Convert.ToString(Convert.ToInt32(workStart)), opName);
|
||
SendMessageFun.SendInfomation("PartLoad", Convert.ToString(Convert.ToInt32(partLoad)), opName);
|
||
SendMessageFun.SendInfomation("EngineTypeGetOverPLC", Convert.ToString(Convert.ToInt32(engineGetOver)), opName);
|
||
SendMessageFun.SendInfomation("FixAllow", Convert.ToString(Convert.ToInt32(fixAllow)), opName);
|
||
SendMessageFun.SendInfomation("MesRead", Convert.ToString(Convert.ToInt32(mesRead)), opName);
|
||
SendMessageFun.SendInfomation("MesReadOver", Convert.ToString(Convert.ToInt32(readOver)), opName);
|
||
SendMessageFun.SendInfomation("MaterialVerifyOver", Convert.ToString(Convert.ToInt32(workFinish)), opName);
|
||
SendMessageFun.SendInfomation("QualityMask", Convert.ToString(qualityMask), opName);
|
||
SendMessageFun.SendInfomation("FalseGO", Convert.ToString(Convert.ToInt32(falseGo)), opName);
|
||
SendMessageFun.SendInfomation("CurrentProduct", engineID + "^" + engineTypeID + "^" + engineType + "^" + partPalletCode, opName);
|
||
|
||
InitAlarm(opName);
|
||
}
|
||
|
||
private void InitAlarm(string opName)
|
||
{
|
||
FuntionMesRead.Alarm_InitAlarm_Send(opName, out Hashtable ht);
|
||
foreach (DictionaryEntry kv in ht)
|
||
{
|
||
FuntionMesRead.Send_AlarmMsg(kv.Key.ToString(), kv.Value.ToString());
|
||
}
|
||
}
|
||
}
|
||
}
|