using System; using System.Data; using bizFacade; using MesServerWork; //using SystemFramework; namespace MesServerFunctions { partial class Functions_BASE_WebSubmit { /// /// 分线上总线的数量 /// public static int SubLineLoadPartCount = 2; /// /// 分线上总线已经匹配的数量 /// public static int SubLineLoadPartCountMatch = 0; /// /// 正常逻辑工作 /// /// /// /// /// /// private static void EngineTypeGetOver_PLC_Work(string OpName, int EngineTypeID, string EngineType, string EngineID, int PartPallet_Code,string OrderForm) { int IsAllowWork; int MES_QualityMask = 1; int repairPart;//读取返修标志 int IsrepairBarcode = 0;//拆解返修标志 //string OrderForm = "";//订单号 string repairBarcode = "";//拆解返修条码 DataTable dt;//读取订单信息 MIS_BASE.Read_OnlineRepair(OpName, out repairPart); BaseDataSystemMES.GetEngineID_Select(OpName, EngineID, out dt); if (dt != null && dt.Rows.Count > 0) { //OrderForm = Convert.ToString(dt.Rows[0]["订单号"]); IsrepairBarcode = Convert.ToInt32(dt.Rows[0]["拆解标志"]); repairBarcode = Convert.ToString(dt.Rows[0]["拆解返修条码"]); } //记录MOBY信息(只限总装工位) BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, OrderForm,EngineTypeID, EngineType, EngineID, PartPallet_Code, repairPart, IsrepairBarcode, repairBarcode); SaveMobyMessage(OpName, EngineTypeID, EngineType, EngineID, OrderForm); BaseDataSystemMES.MaterialPush_EngineIDStatus_Insert(OpName); BaseDataSystemMES.MesServer_Process_EngineTypeOver(OpName); Sendmessage("5123", "1111", OpName); MIS_BASE.Read_PalletInfo(OpName, out MES_QualityMask); SendInfomation("QualityMask", Convert.ToString(MES_QualityMask), OpName); if (MES_QualityMask != 1) { //工作完成 MIS_BASE.Write_MaterialVerifyOver(OpName, true); SendInfomation("NgGO", "1", OpName);//显示不合格标志 return; } BaseDataSystemMES.MesServer_Judge_IsCanWork(OpName, out IsAllowWork); if (IsAllowWork == 1) { Match(OpName, EngineID, EngineTypeID, EngineType, PartPallet_Code);//匹配 } } /// /// 保存MOBY信息 /// /// /// /// /// private static void SaveMobyMessage(string OpName, int engineTypeID, string engineType, string engineID, string orderForm) { if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null) { MIS_BASE.InitHashtable_MesServerCode(); } if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID.ContainsKey(OpName)) { MIS_BASE.hashtable_EngineGetOver_EngineTypeID[OpName] = engineTypeID; } if (MIS_BASE.hashtable_EngineGetOver_EngineType.ContainsKey(OpName)) { MIS_BASE.hashtable_EngineGetOver_EngineType[OpName] = engineType; } if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName)) { MIS_BASE.hashtable_EngineGetOver_EngineID[OpName] = engineID; } if (MIS_BASE.hashtable_EngineGetOver_OrderForm.ContainsKey(OpName)) { MIS_BASE.hashtable_EngineGetOver_OrderForm[OpName] = orderForm; } } /// /// 返修件需要工作 /// /// 工位号 private static void IsNeedRepaire_OK(string OpName) { int isRepair; int engineTypeID; string engineType = ""; string engineID = ""; string palletCode = ""; string orderForm = ""; string repairCode = ""; //从监控系统中查询出本工位信息 BaseDataSystemMES.OpName_MIS_Moby_Select(OpName, out orderForm, out engineTypeID, out engineType, out engineID, out palletCode, out isRepair, out repairCode); EngineTypeGetOver_PLC_Work(OpName, engineTypeID, engineType, engineID, Convert.ToInt32(palletCode),orderForm); } /// /// 正常匹配分线和总线 /// /// /// 总线工件号 /// 总线工件机型代码 /// 总线工件机型 private static void Match(string opName, string engineID, int engineTypeID, string engineType, int PartPallet_Code) { try { bool m_EngineGetOver_PLC_SubLine; int engineTypeID_SubLine; int partPallet_Code_SubLine; int PalletInfo = 1;//总线托盘状态 string opName_SubLine = "";//分线工件信息 string engineID_SubLine; string engineType_SubLine; string AlarmStr; if (MIS_BASE.hashtable_OpNameRepair == null) { MIS_BASE.InitHashtable_MesServerCode(); } //第一步:获取分线中间交互工位号 if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(opName)) { opName_SubLine = MIS_BASE.hashtable_OpNameRepair[opName].ToString(); } if (opName_SubLine == "") { return; } //第二步:获取分线传递机型信号 MIS_BASE.Read_EngineGetOver_PLC(opName_SubLine, out m_EngineGetOver_PLC_SubLine); if (!m_EngineGetOver_PLC_SubLine) return;//必须工件同时到位才能进行匹配 //第三步:判断合格标志 MIS_BASE.Read_PalletInfo(opName_SubLine, out PalletInfo); if (PalletInfo == 2) return; //若不合格则返回不进行匹配 string OrderForm; //第四步:获取分线的信息,匹配验证 MIS_BASE.GetEngineTypeFromPLC(opName_SubLine, out engineTypeID_SubLine, out engineType_SubLine, out engineID_SubLine, out partPallet_Code_SubLine,out OrderForm); //判断分线数据是否合格 //if (!BaseDataSystemMES.QulityDataVerify(opName, engineID_SubLine, out AlarmStr) && !BaseDataSystemMES.QualityVerifyStatus_Hash_Read(opName)) //{ // SendInfomation("LineoutAlert", AlarmStr, opName); // return; //} if (engineTypeID_SubLine == engineTypeID) { BaseDataSystemMES.SubLineLoadPartCountMatch_Select(opName, out SubLineLoadPartCountMatch); SubLineLoadPartCountMatch = SubLineLoadPartCountMatch + 1; BaseDataSystemMES.SubLineLoadPartCountMatch_Update(opName, SubLineLoadPartCountMatch); BaseDataSystemMES.MailLineAndSubLineData_Insert(engineID, engineTypeID, engineType, engineID_SubLine);//分线上总线数据转移 MIS_BASE.Write_Match(opName, true);//匹配结果 MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成 if(SubLineLoadPartCountMatch== SubLineLoadPartCount) { MIS_BASE.Write_FixAllow(opName, true); SubLineLoadPartCountMatch = 0; BaseDataSystemMES.SubLineLoadPartCountMatch_Update(opName, SubLineLoadPartCountMatch); } SendInfomation("MatchSuccess", "1", opName); sendmessage(opName, 1, "Match");//匹配结果 } else { MIS_BASE.Write_Match(opName, false);//匹配结果 MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成//68:1、取消返修;2、匹配成功 自己监控发送 MES|MatchingCompleted //发送匹配完成和匹配结果信息 AsyncSendMessage_Notice(opName,"匹配失败,工件型号不匹配!"); SendInfomation("MatchSuccess", "0", opName); sendmessage(opName, 0, "Match");//匹配结果 } } catch (Exception err) { ////ApplicationLog.WriteLog("Match:" + err.ToString()); } } /// /// 强制匹配分线和总线 /// /// private static void ForceMatch(string opName) { try { bool m_EngineGetOver_PLC_SubLine; bool m_EngineGetOver_PLC; int engineTypeID_SubLine; int engineTypeID; int partPallet_Code_SubLine; int partPallet_Code; string opName_SubLine = "";//分线工件信息 string engineID_SubLine; string engineType_SubLine; string engineID; string engineType; if (MIS_BASE.hashtable_OpNameRepair == null) { MIS_BASE.InitHashtable_MesServerCode(); } //获取分线中间交互工位号 if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(opName)) { opName_SubLine = MIS_BASE.hashtable_OpNameRepair[opName].ToString(); } if (opName_SubLine == "") { return; } MIS_BASE.Read_EngineGetOver_PLC(opName_SubLine, out m_EngineGetOver_PLC_SubLine);//1:读取分线工件到位的传递机型信号。 if (!m_EngineGetOver_PLC_SubLine) return;//必须工件同时到位才能进行匹配 MIS_BASE.Read_EngineGetOver_PLC(opName, out m_EngineGetOver_PLC);//2:读取总线工件到位的传递机型信号。 if (!m_EngineGetOver_PLC) return;//必须工件同时到位才能进行匹配 string OrderForm; MIS_BASE.GetEngineTypeFromPLC(opName_SubLine, out engineTypeID_SubLine, out engineType_SubLine, out engineID_SubLine, out partPallet_Code_SubLine,out OrderForm);//获取分线的信息 MIS_BASE.GetEngineTypeFromPLC(opName, out engineTypeID, out engineType, out engineID, out partPallet_Code, out OrderForm); BaseDataSystemMES.MailLineAndSubLineData_Insert(engineID, engineTypeID, engineType, engineID_SubLine);//分线上总线数据转移 MIS_BASE.Write_Match(opName, true);//匹配结果 MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成 SendInfomation("MatchSuccess", "1", opName);//界面显示匹配成功 MIS_BASE.Write_FixAllow(opName, true);//允许PLC工作 //发送匹配完成和匹配结果信息 sendmessage(opName, 1, "MatchingComplete");//匹配完成 sendmessage(opName, 1, "Match");//匹配结果 } catch { } } } }