Files
2026-05-29 13:44:10 +08:00

316 lines
13 KiB
C#
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
using System;
using System.Data;
using bizFacade;
using MesServerWork;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 分线上总线的数量
/// </summary>
public static int SubLineLoadPartCount = 2;
/// <summary>
/// 分线上总线已经匹配的数量
/// </summary>
public static int SubLineLoadPartCountMatch = 0;
/// <summary>
/// 正常逻辑工作
/// </summary>
/// <param name="OpName"></param>
/// <param name="EngineTypeID"></param>
/// <param name="EngineType"></param>
/// <param name="EngineID"></param>
/// <param name="PartPallet_Code"></param>
private void EngineTypeGetOver_PLC_Work(string OpName, int EngineTypeID, string EngineType, string EngineID, int PartPallet_Code,string OrderForm)
{
int IsAllowWork;
int RepairPartStatusPLC = 0;
int MES_QualityMask = 1;
if (EngineTypeID <= 0 || EngineID.Length == 0 || EngineType.Length == 0 || OrderForm.Length == 0)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "PLC传递机型为空");
return;
}
//初始化物料临时表
//第二步将零件信息转移到零件_临时表中本地BOM与订单BOM的选择显示关系
BaseDataSystemMES.MesServer_Process_EngineTypeOver_BQ_FirstOP(OpName);
//5 显示订单、机型信息 线首工位用
SendMessage.ShowMoby_FirstOpName(OpName);
//3显示操作指导图片 PicShow_String_FirstOpName
SendMessage.PicShow_FirstOpName(OpName);
//1直接在界面通过选择机型确认工序内容
SendMessage.ProcessList_FirstOpName(OpName);
//界面显示物料信息
SendMessage.MaterialList_FirstOpName(OpName);
//电子看板_装配零件_临时表_增加_北汽
//第二步将零件信息转移到零件_临时表中
// BaseDataSystemMES.MesServer_Process_EngineTypeOverBQ(OpName);
//通知web显示
SendMessageFun.SendMessage("5", "1", OpName);
//第四步,获取是否允许工作
BaseDataSystemMES.MesServer_Judge_IsCanWork(OpName, out IsAllowWork);
// 暂时先定义为扫描完成才能进行压装工作,因为考虑到工作完成后,操作工未必会去扫描物料的情况
if (IsAllowWork == 1)
{
//通知PLC允许工作,允许工作在保存完成时清空
MIS_BASE.Write_FixAllow(OpName, true);
}
else
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "请扫描物料!");
}
}
/// <summary>
/// 二次工作
/// </summary>
/// <param name="OpName"></param>
private void EngineTypeGetOver_PLC_Work_two(string OpName)
{
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
EngineTypeGetOver_PLC_Work(OpName, EngineTypeID, EngineType, EngineID, Convert.ToInt32(PartPallet_Code), OrderForm);
}
/// <summary>
/// 跳过二次工作
/// </summary>
/// <param name="OpName"></param>
private void EngineTypeGetOver_PLC_Work_Skip(string OpName)
{
//MIS_BASE.Write_MesReadOver(OpName, true);
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
/// <summary>
/// 保存MOBY信息
/// </summary>
/// <param name="OpName"></param>
/// <param name="engineTypeID"></param>
/// <param name="engineType"></param>
/// <param name="engineID"></param>
private void SaveMobyMessage(string OpName, int engineTypeID, string engineType, string engineID, string orderForm)
{
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID.ContainsKey(OpName))
{
MIS_BASE.hashtable_EngineGetOver_EngineTypeID[OpName] = engineTypeID;
}
if (MIS_BASE.hashtable_EngineGetOver_EngineType.ContainsKey(OpName))
{
MIS_BASE.hashtable_EngineGetOver_EngineType[OpName] = engineType;
}
if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName))
{
MIS_BASE.hashtable_EngineGetOver_EngineID[OpName] = engineID;
}
if (MIS_BASE.hashtable_EngineGetOver_OrderForm.ContainsKey(OpName))
{
MIS_BASE.hashtable_EngineGetOver_OrderForm[OpName] = orderForm;
}
}
/// <summary>
/// 返修件需要工作
/// </summary>
/// <param name="OpName">工位号</param>
private void IsNeedRepaire_OK(string OpName)
{
int isRepair;
int engineTypeID;
string engineType = "";
string engineID = "";
string palletCode = "";
string orderForm = "";
string repairCode = "";
//从监控系统中查询出本工位信息
BaseDataSystemMES.OpName_MIS_Moby_Select(OpName,
out orderForm, out engineTypeID, out engineType,
out engineID, out palletCode, out isRepair, out repairCode);
EngineTypeGetOver_PLC_Work(OpName, engineTypeID, engineType, engineID, Convert.ToInt32(palletCode),orderForm);
}
/// <summary>
/// 正常匹配分线和总线
/// </summary>
/// <param name="opName"></param>
/// <param name="engineID">总线工件号</param>
/// <param name="engineTypeID">总线工件机型代码</param>
/// <param name="engineType">总线工件机型</param>
private void Match(string opName, string engineID, int engineTypeID, string engineType, int PartPallet_Code)
{
try
{
bool m_EngineGetOver_PLC_SubLine;
int engineTypeID_SubLine;
int partPallet_Code_SubLine;
int PalletInfo = 1;//总线托盘状态
string opName_SubLine = "";//分线工件信息
string engineID_SubLine;
string engineType_SubLine;
string AlarmStr;
if (MIS_BASE.hashtable_OpNameRepair == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
//第一步:获取分线中间交互工位号
if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(opName))
{
opName_SubLine = MIS_BASE.hashtable_OpNameRepair[opName].ToString();
}
if (opName_SubLine == "")
{
return;
}
//第二步:获取分线传递机型信号
MIS_BASE.Read_EngineGetOver_PLC(opName_SubLine, out m_EngineGetOver_PLC_SubLine);
if (!m_EngineGetOver_PLC_SubLine) return;//必须工件同时到位才能进行匹配
//第三步:判断合格标志
MIS_BASE.Read_PalletInfo(opName_SubLine, out PalletInfo);
if (PalletInfo == 2) return; //若不合格则返回不进行匹配
string OrderForm;
//第四步:获取分线的信息,匹配验证
MIS_BASE.GetEngineTypeFromPLC(opName_SubLine, out engineTypeID_SubLine, out engineType_SubLine, out engineID_SubLine, out partPallet_Code_SubLine,out OrderForm);
//判断分线数据是否合格
//if (!BaseDataSystemMES.QulityDataVerify(opName, engineID_SubLine, out AlarmStr) && !BaseDataSystemMES.QualityVerifyStatus_Hash_Read(opName))
//{
// SendInfomation("LineoutAlert", AlarmStr, opName);
// return;
//}
if (engineTypeID_SubLine == engineTypeID)
{
BaseDataSystemMES.SubLineLoadPartCountMatch_Select(opName, out SubLineLoadPartCountMatch);
SubLineLoadPartCountMatch = SubLineLoadPartCountMatch + 1;
BaseDataSystemMES.SubLineLoadPartCountMatch_Update(opName, SubLineLoadPartCountMatch);
BaseDataSystemMES.MailLineAndSubLineData_Insert(engineID, engineTypeID, engineType, engineID_SubLine);//分线上总线数据转移
MIS_BASE.Write_Match(opName, true);//匹配结果
MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成
if(SubLineLoadPartCountMatch== SubLineLoadPartCount)
{
MIS_BASE.Write_FixAllow(opName, true);
SubLineLoadPartCountMatch = 0;
BaseDataSystemMES.SubLineLoadPartCountMatch_Update(opName, SubLineLoadPartCountMatch);
}
SendMessageFun.SendInfomation("MatchSuccess", "1", opName);
sendmessage(opName, 1, "Match");//匹配结果
}
else
{
MIS_BASE.Write_Match(opName, false);//匹配结果
MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成//68:1、取消返修2、匹配成功 自己监控发送 MES|MatchingCompleted
//发送匹配完成和匹配结果信息
SendMessageFun.AsyncSendMessage_Notice(opName,"匹配失败,工件型号不匹配!");
SendMessageFun.SendInfomation("MatchSuccess", "0", opName);
sendmessage(opName, 0, "Match");//匹配结果
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog("Match:" + err.ToString());
}
}
/// <summary>
/// 强制匹配分线和总线
/// </summary>
/// <param name="opName"></param>
private void ForceMatch(string opName)
{
try
{
bool m_EngineGetOver_PLC_SubLine;
bool m_EngineGetOver_PLC;
int engineTypeID_SubLine;
int engineTypeID;
int partPallet_Code_SubLine;
int partPallet_Code;
string opName_SubLine = "";//分线工件信息
string engineID_SubLine;
string engineType_SubLine;
string engineID;
string engineType;
if (MIS_BASE.hashtable_OpNameRepair == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
//获取分线中间交互工位号
if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(opName))
{
opName_SubLine = MIS_BASE.hashtable_OpNameRepair[opName].ToString();
}
if (opName_SubLine == "")
{
return;
}
MIS_BASE.Read_EngineGetOver_PLC(opName_SubLine, out m_EngineGetOver_PLC_SubLine);//1:读取分线工件到位的传递机型信号。
if (!m_EngineGetOver_PLC_SubLine) return;//必须工件同时到位才能进行匹配
MIS_BASE.Read_EngineGetOver_PLC(opName, out m_EngineGetOver_PLC);//2:读取总线工件到位的传递机型信号。
if (!m_EngineGetOver_PLC) return;//必须工件同时到位才能进行匹配
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(opName_SubLine, out engineTypeID_SubLine, out engineType_SubLine, out engineID_SubLine, out partPallet_Code_SubLine,out OrderForm);//获取分线的信息
MIS_BASE.GetEngineTypeFromPLC(opName, out engineTypeID, out engineType, out engineID, out partPallet_Code, out OrderForm);
BaseDataSystemMES.MailLineAndSubLineData_Insert(engineID, engineTypeID, engineType, engineID_SubLine);//分线上总线数据转移
MIS_BASE.Write_Match(opName, true);//匹配结果
MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成
SendMessageFun.SendInfomation("MatchSuccess", "1", opName);//界面显示匹配成功
MIS_BASE.Write_FixAllow(opName, true);//允许PLC工作
//发送匹配完成和匹配结果信息
sendmessage(opName, 1, "MatchingComplete");//匹配完成
sendmessage(opName, 1, "Match");//匹配结果
}
catch
{
}
}
}
}