chore: 初始化北汽福田MES采集程序

This commit is contained in:
yexingqiang
2026-05-29 13:44:10 +08:00
commit c5e248e993
1399 changed files with 187196 additions and 0 deletions

View File

@@ -0,0 +1,15 @@
namespace MesServerFunctions
{
partial class Function1053
{
//针对“MIS.BizFacade.Dll”中没有的存储过程在此类中新建
//新建原则所有的函数用private,只允许在内部使用
//针对单个工艺特殊需要新建存储过程但是存储过程不能被加入到“MIS.BizFacade.Dll”中
private void aa()
{
}
}
}

View File

@@ -0,0 +1,74 @@
using System;
using System.Collections.Generic;
using System.Data.SqlClient;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using DataLinkMesWork;
namespace MesServerFunctions
{
public class Db
{
/// <summary>
/// 北汽福田变速器序列号总线上线_获得机型信息
/// </summary>
/// <param name="partSn"></param>
/// <param name="EngineTypeID"></param>
/// <param name="EngineType"></param>
/// <param name="EngineID"></param>
/// <param name="IsRepeatedNumber"> 0 不重号1 重号2失败</param>
/// <returns></returns>
public static bool GetEngineType(string partSn, out int EngineTypeID, out string EngineType, out string EngineID,out int IsRepeatedNumber)
{
DataTable dt = new DataTable();
EngineTypeID = 0;
EngineType = "";
EngineID = "";
IsRepeatedNumber = 2;
string produceName = "北汽福田变速器序列号总线上线_获得机型信息";
SqlParameter[] thisParms = new SqlParameter[1];
thisParms[0] = new System.Data.SqlClient.SqlParameter("@变速器序列号", partSn);
thisParms[2].Direction = ParameterDirection.Output;
if (DataAccess.ExecuteStoredProcedure(produceName, ref thisParms,out dt))
{
if(dt.Rows.Count > 0)
{
IsRepeatedNumber = Convert.ToInt32( dt.Rows[0]["IsRepeatedNumber"]);
EngineTypeID = Convert.ToInt32(dt.Rows[0]["EngineTypeID"]);
EngineType = dt.Rows[0]["EngineType"].ToString();
EngineID = partSn;
return true;
}
}
return false;
}
/// <summary>
/// 北汽福田变速器序列号总线上线_增加
/// </summary>
/// <param name="partSn"></param>
/// <param name="EngineTypeID"></param>
/// <param name="EngineType"></param>
/// <param name="OpName"></param>
/// <returns></returns>
public static bool UpLoadOpNameInsert(string partSn, int EngineTypeID, string EngineType, string OpName)
{
string produceName = "北汽福田变速器序列号总线上线_增加";
SqlParameter[] thisParms = new SqlParameter[4];
thisParms[0] = new System.Data.SqlClient.SqlParameter("@变速器序列号", partSn);
thisParms[1] = new System.Data.SqlClient.SqlParameter("@基本型号代码", EngineTypeID);
thisParms[2] = new System.Data.SqlClient.SqlParameter("@基本型号", EngineType);
thisParms[3] = new System.Data.SqlClient.SqlParameter("@工位号", OpName);
return DataAccess.ExecuteStoredProcedure(produceName, ref thisParms);
}
// ALTER PROCEDURE[dbo].[北汽福田变速器序列号总线上线_增加]
// @变速器序列号 nvarchar(50)='1333 050 062 0001*146012023*12345678',--'1333 050 062 0001'
//@基本型号代码 int=1,
//@基本型号 nvarchar(50)='1333 050 062 0001',
//@工位号 nvarchar(50) = 'J05PA010'
}
}

View File

@@ -0,0 +1,10 @@
""
{
"FILE_VERSION" = "9237"
"ENLISTMENT_CHOICE" = "NEVER"
"PROJECT_FILE_RELATIVE_PATH" = "relative:MesServer.Function\\Function02"
"NUMBER_OF_EXCLUDED_FILES" = "0"
"ORIGINAL_PROJECT_FILE_PATH" = ""
"NUMBER_OF_NESTED_PROJECTS" = "0"
"SOURCE_CONTROL_SETTINGS_PROVIDER" = "PROVIDER"
}

View File

@@ -0,0 +1,171 @@
<?xml version="1.0" encoding="utf-8"?>
<Project ToolsVersion="12.0" DefaultTargets="Build" xmlns="http://schemas.microsoft.com/developer/msbuild/2003">
<PropertyGroup>
<Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration>
<Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform>
<ProductVersion>8.0.30703</ProductVersion>
<SchemaVersion>2.0</SchemaVersion>
<ProjectGuid>{CA8A12C5-7BF0-4489-93FA-180B1C492BBA}</ProjectGuid>
<OutputType>Library</OutputType>
<AppDesignerFolder>Properties</AppDesignerFolder>
<RootNamespace>Function1053</RootNamespace>
<AssemblyName>Function1053</AssemblyName>
<TargetFrameworkVersion>v4.8</TargetFrameworkVersion>
<FileAlignment>512</FileAlignment>
<SccProjectName>
</SccProjectName>
<SccLocalPath>
</SccLocalPath>
<SccAuxPath>
</SccAuxPath>
<SccProvider>
</SccProvider>
<TargetFrameworkProfile />
<NuGetPackageImportStamp>
</NuGetPackageImportStamp>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Debug|AnyCPU' ">
<DebugSymbols>true</DebugSymbols>
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>..\..\..\dll_fun\</OutputPath>
<DefineConstants>DEBUG;TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<UseVSHostingProcess>false</UseVSHostingProcess>
<Prefer32Bit>false</Prefer32Bit>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<Prefer32Bit>false</Prefer32Bit>
</PropertyGroup>
<ItemGroup>
<Reference Include="MQTTnet">
<HintPath>..\..\..\Common\dll\MQTTnet.dll</HintPath>
</Reference>
<Reference Include="MQTTnet.Extensions.ManagedClient">
<HintPath>..\..\..\Common\dll\MQTTnet.Extensions.ManagedClient.dll</HintPath>
</Reference>
<Reference Include="Newtonsoft.Json, Version=6.0.0.0, Culture=neutral, PublicKeyToken=30ad4fe6b2a6aeed, processorArchitecture=MSIL">
<SpecificVersion>False</SpecificVersion>
<HintPath>..\..\..\Common\dll\Newtonsoft.Json.dll</HintPath>
</Reference>
<Reference Include="System" />
<Reference Include="System.Core" />
<Reference Include="System.Drawing" />
<Reference Include="System.Net.Http">
<HintPath>..\..\DLL\System.Net.Http.dll</HintPath>
</Reference>
<Reference Include="System.Net.Security, Version=4.0.1.2, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Net.Security.4.3.2\lib\net46\System.Net.Security.dll</HintPath>
</Reference>
<Reference Include="System.Net.WebSockets, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Net.WebSockets.4.3.0\lib\net46\System.Net.WebSockets.dll</HintPath>
</Reference>
<Reference Include="System.Net.WebSockets.Client, Version=4.0.1.1, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Net.WebSockets.Client.4.3.2\lib\net46\System.Net.WebSockets.Client.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.Algorithms, Version=4.1.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.Algorithms.4.3.0\lib\net461\System.Security.Cryptography.Algorithms.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.Encoding, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.Encoding.4.3.0\lib\net46\System.Security.Cryptography.Encoding.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.Primitives, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.Primitives.4.3.0\lib\net46\System.Security.Cryptography.Primitives.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.X509Certificates, Version=4.1.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.X509Certificates.4.3.0\lib\net461\System.Security.Cryptography.X509Certificates.dll</HintPath>
</Reference>
<Reference Include="System.Windows.Forms" />
<Reference Include="System.Xml.Linq" />
<Reference Include="System.Data.DataSetExtensions" />
<Reference Include="Microsoft.CSharp" />
<Reference Include="System.Data" />
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="Db.cs" />
<Compile Include="Methods\EngineGetOverBaseWork.cs" />
<Compile Include="Methods\SubmitToMisweb.cs" />
<Compile Include="DataAccess\DataAccess.cs" />
<Compile Include="MesServerFunction\Fun_1053.cs" />
<Compile Include="Methods\UDP.Send.cs" />
<Compile Include="OpcServer\Barcode.cs" />
<Compile Include="OpcServer\ConfirmOkGo.cs" />
<Compile Include="OpcServer\EngineGetOver.cs" />
<Compile Include="OpcServer\FalseGO.cs" />
<Compile Include="OpcServer\HeartBeat.cs" />
<Compile Include="OpcServer\J07PA010WorkStart.cs" />
<Compile Include="OpcServer\MesRead.cs" />
<Compile Include="OpcServer\MesReadOver.cs" />
<Compile Include="OpcServer\PartLoad.cs" />
<Compile Include="OpcServer\MesSaveNowData.cs" />
<Compile Include="OpcServer\WebSubmit.cs" />
<Compile Include="OpcServer\WorkIsOk.cs" />
<Compile Include="OpcServer\WorkStart.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
</ItemGroup>
<ItemGroup>
<None Include="app.config" />
<None Include="packages.config" />
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\..\..\Common\00MesWorkMqtt\MesWorkMqtt\00MesWorkMqtt.csproj">
<Project>{f55da1a0-a982-4479-8c47-0d9a5aaf3e18}</Project>
<Name>00MesWorkMqtt</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\01DoWhatPlc\01_01DoWhatPlc.csproj">
<Project>{0d1af432-439a-4920-8692-43ae139f5530}</Project>
<Name>01_01DoWhatPlc</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\02WebApiCall\02_02WebApiCallPLC.csproj">
<Project>{3e6d1dd5-01c9-435f-9941-61f906ce35bb}</Project>
<Name>02_02WebApiCallPLC</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\04DataBaseAccess\DataBaseAccess\04-DataBaseAccess.csproj">
<Project>{f434e066-4c59-47c8-aa82-6f48cc84501a}</Project>
<Name>04-DataBaseAccess</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\07WebBusinessFacade\BusinessFacade\07BusinessFacade.csproj">
<Project>{f0a0c525-03fd-428a-9b17-7f54aa0e4475}</Project>
<Name>07BusinessFacade</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\08WebFun_base\WebFun_base\08-WebFun_base.csproj">
<Project>{d98be764-adeb-488d-9714-61e308aa8201}</Project>
<Name>08-WebFun_base</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\09MesDataFunction\MesDataFunction\09-MesDataFunction.csproj">
<Project>{90e76fb4-646d-45e2-95db-0b8ab4e465d6}</Project>
<Name>09-MesDataFunction</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\MisDataFun\SendMessageToWebMqtt\12SendMessageToWeb.csproj">
<Project>{e4eb6420-906d-4672-947a-ca33ddcdadfc}</Project>
<Name>12SendMessageToWeb</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\MIS_FuntionSaveData\MIS_FuntionSaveData\13.3MIS_FuntionSaveData.csproj">
<Project>{55b510c1-59e9-4bfd-ae84-d76d46f6e365}</Project>
<Name>02-13.3MIS_FuntionSaveData</Name>
</ProjectReference>
</ItemGroup>
<Import Project="$(MSBuildToolsPath)\Microsoft.CSharp.targets" />
<Import Project="..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets" Condition="Exists('..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets')" />
<Target Name="EnsureNuGetPackageBuildImports" BeforeTargets="PrepareForBuild">
<PropertyGroup>
<ErrorText>这台计算机上缺少此项目引用的 NuGet 程序包。使用“NuGet 程序包还原”可下载这些程序包。有关更多信息,请参见 http://go.microsoft.com/fwlink/?LinkID=322105。缺少的文件是 {0}。</ErrorText>
</PropertyGroup>
<Error Condition="!Exists('..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets')" Text="$([System.String]::Format('$(ErrorText)', '..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets'))" />
</Target>
<!-- To modify your build process, add your task inside one of the targets below and uncomment it.
Other similar extension points exist, see Microsoft.Common.targets.
<Target Name="BeforeBuild">
</Target>
<Target Name="AfterBuild">
</Target>
-->
</Project>

View File

@@ -0,0 +1,337 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Threading;
namespace MesServerFunctions
{
public partial class FunctionMES
{
object lockFunWork;
//public void FunWork(DoWhatPlc.CustomeEvetnArgs e)
public void FunWork(string recData)
{
lockFunWork = new object();
lock (lockFunWork)
{
List<string> dataArray = DoWhatPlc.MessageText.GetCmdStringList(recData);
//string[] dataArray = recData.Split('|');
//if (dataArray.Count != 4)
//return;
//消息来源
string m_Source = dataArray[0].ToString();
//消息类型 Barcode
string m_Command = dataArray[1].ToString();
//工位号
string m_OpName = dataArray[2].ToString();
//消息参数
string m_Value = dataArray[3].ToString();
DoWhatPlc.CustomeEvetnArgs e = new DoWhatPlc.CustomeEvetnArgs();// = Newtonsoft.Json.JsonConvert.DeserializeObject<DoWhatPlc.CustomeEvetnArgs>(m_Value);
string tagValue;
switch (m_Source)
{
case "BarCode":
e.OpName = m_OpName;
e.TagValue = m_Value;
fun_Barcode(e);
break;
case "WEB":
e.OpName = m_OpName;
e.TagValue = m_Command + "|" + m_Value;
fun_WebSubmit(e);
break;
case "PLC":
e = Newtonsoft.Json.JsonConvert.DeserializeObject<DoWhatPlc.CustomeEvetnArgs>(m_Value);
switch (e.TagValue.ToString().ToLower())
{
case "false":
tagValue = "0";
break;
case "true":
tagValue = "1";
break;
default:
tagValue = e.TagValue.ToString();
break;
}
e.TagValue = tagValue;
switch (e.TagTypeCodeID.ToString())
{
//PLC 工件到位
case "2":
fun_WorkStart(e);
break;
//PLC 申请上线
case "43":
fun_PartLoad(e);
break;
//PLC 允许保存质量数据
case "19":
fun_MesRead(e);
break;
//MES 保存数据完成
case "20":
fun_MesReadOver(e);
break;
//PLC 工位合格标志
case "22":
fun_IsOk(e);
break;
//PLC PA010走流程点 6s1
case "25":
if(m_OpName == "J07PA010")
{
e.TagTypeID = 0;
e.TagTypeCodeID = 30; // 写入报警点变量位置
fun_J07PA010_WorkStart(e);
}
break;
//PLC PA010走流程点 6s2
case "26":
if (m_OpName == "J07PA010")
{
e.TagTypeID = 1;
e.TagTypeCodeID = 31; // 写入报警点变量位置
//fun_J07PA010_WorkStart(e);
}
break;
//PLC PA010走流程点 6s3
case "27":
if (m_OpName == "J07PA010")
{
e.TagTypeID = 1;
//e.TagTypeID = 2;
e.TagTypeCodeID = 31; // 写入报警点变量位置
//e.TagTypeCodeID = 32; // 写入报警点变量位置
fun_J07PA010_WorkStart(e);
}
break;
//PLC PA010走流程点 5s1
case "28":
if (m_OpName == "J07PA010")
{
e.TagTypeID = 0;
e.TagTypeCodeID = 33; // 写入报警点变量位置
fun_J07PA010_WorkStart(e);
}
break;
//PLC PA010走流程点 5s2
case "29":
if (m_OpName == "J07PA010")
{
e.TagTypeID = 1;
e.TagTypeCodeID = 34; // 写入报警点变量位置
fun_J07PA010_WorkStart(e);
}
break;
//PLC PA010走流程点 5s3
case "35":
if (m_OpName == "J07PA010")
{
e.TagTypeID = 2;
e.TagTypeCodeID = 36; // 写入报警点变量位置
fun_J07PA010_WorkStart(e);
}
break;
//PLC 螺栓补拧结束
case "30":
int value = Convert.ToInt32(MIS_BASE.ReadPLC(30, m_OpName));
if (value == 0)
{
MIS_BASE.WritePLC(77, m_OpName, 0);
MIS_BASE.WritePLC(88, m_OpName, 0);
//先修改按钮显示
BaseDataSystemMES.SetButtomShouOrHide(m_OpName, "MES_BoltAddWorkStart", 1, 1, "MES_BoltAddWorkEnd", 0);
//通知前端刷新按钮
SendMessageFun.SendInfomation("SetButtomShouOrHide", "1", m_OpName);
}
break;
//PLC 传递机型
case "44":
fun_EngineTypeGetOverPLC(e);
break;
//MES 合格放行
case "51":
fun_ConfirmOkGo(e);
break;
//MES 不合格放行
case "8":
fun_FalseGo(e);
break;
//MES保存实时质量数据
case "65":
fun_MesSaveNowData(e);
break;
//MES 系统健康心跳
case "14":
fun_HeartBeatMIS(e);
break;
case "63":
string S_plcStatus;//DBX501.5 PLC直通1 强制放行 0 正常循环
MIS_BASE.Read_TagTypeID(63, m_OpName, out S_plcStatus);
if (Convert.ToInt32(S_plcStatus) == 0)
{
SendMessageFun.SendInfomation("PlcStatus", "0", m_OpName);
}
else
{
SendMessageFun.SendInfomation("PlcStatus", "1", m_OpName);
}
break;
// PLC 程序号
case "125":
// 将程序号转发给前端页面
SendMessageFun.SendInfomation("CodeNumber", e.TagValue.ToString(), m_OpName);
break;
// PLC 程序号的第几颗螺丝
case "126":
SendMessageFun.SendInfomation("CodeNumberWorkNumber", e.TagValue.ToString(), m_OpName);
break;
}
break;
}
}
}
//1.工件到位后PLC给MES传递机型(DBX0.4)(44)
//MES判断条码是否全部扫描完成
//PLC给出允许保存(DBX100.2)(19)MES见到(DBX100.2)(19)为1后给出保存完成(DBX102.2)(20)
//PLC见到保存完成(DBX102.2)(20)为1后清空允许保存(DBX100.2)(19)
//MES见到允许保存(DBX100.2)(19)为0后清空保存完成(DBX102.2)(20)
//MES判断总合格标志(INT104)(21)为1后给出合格放行(DBX2.5)(51)
/// <summary>
/// PA010 工作流程开始
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_J07PA010_WorkStart(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(J07PA010WorkStart, e);
}
/// <summary>
/// 扫描条码
/// </summary>
/// <param name="OpName"></param>
/// <param name="barcode"></param>
///
public void fun_Barcode(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(Barcode, e);
}
/// <summary>
/// 传递机型
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_EngineTypeGetOverPLC(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(EngineTypeGetOver_PLC, e);
}
/// <summary>
/// 系统健康心跳监测
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_HeartBeatMIS(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(HeartBeat, e);
}
/// <summary>
/// 合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_ConfirmOkGo(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(ConfirmOkGo, e);
}
/// <summary>
/// 不合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_FalseGo(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(FalseGO, e);
}
/// <summary>
/// 允许保存
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_MesRead(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(MesRead, e);
}
/// <summary>
/// 保存完成
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_MesReadOver(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(MesReadOver, e);
}
/// <summary>
/// 工件到位离开(清空所有的MES信号)
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_WorkStart(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(WorkStart, e);
}
/// <summary>
/// 申请上线 43
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_PartLoad(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(PartLoad, e);
}
/// <summary>
/// 处理WEB页面发送过来的请求m_Command + "|" + m_Value;
/// </summary>
/// <param name="OpName"></param>
/// <param name="Content"></param>
public void fun_WebSubmit(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(WebSubmit, e);
}
/// <summary>
/// MES实时保存质量数据
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_MesSaveNowData(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(MesSaveNowData, e);
}
/// <summary>
/// 工位是否合格
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_IsOk(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(IsOk, e);
}
}
}

View File

@@ -0,0 +1,120 @@
using System;
using System.Data;
using bizFacade;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 正常逻辑工作(传递机型)
/// </summary>
/// <param name="OpName"></param>
/// <param name="EngineTypeID"></param>
/// <param name="EngineType"></param>
/// <param name="EngineID"></param>
/// <param name="PartPallet_Code"></param>
private void EngineTypeGetOver_PLC_Work(string OpName, int EngineTypeID, string EngineType, string EngineID, int PartPallet_Code,string OrderForm)
{
int IsAllowWork;
int RepairPartStatusPLC = 0;
int MES_QualityMask = 1;
//string OrderForm = "";//订单号
//DataTable dt;
if (EngineTypeID <= 0 || EngineID.Length == 0 || EngineType.Length == 0 || OrderForm.Length == 0)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "PLC传递机型为空");
return;
}
//电子看板_装配零件_临时表_增加_北汽
//第二步将零件信息转移到零件_临时表中
BaseDataSystemMES.MesServer_Process_EngineTypeOverBQ(OpName);
//通知web显示
SendMessageFun.SendMessage("1235", "1111", OpName);
MIS_BASE.Read_PalletInfo(OpName, out MES_QualityMask);//合格标志
MIS_BASE.Read_RepairStatus_PLC(OpName, out RepairPartStatusPLC);//返修标志
SendMessageFun.SendInfomation("QualityMask", Convert.ToString(MES_QualityMask), OpName);//显示合格标志
SendMessageFun.SendInfomation("RepairPartStatusPLC", Convert.ToString(RepairPartStatusPLC), OpName);//显示返修标志
if (MES_QualityMask == 2)
{
//// 工作完成
//MIS_BASE.Write_MaterialVerifyOver(OpName, true);
//SendMessageFun.SendInfomation("NgGO", "1", OpName);//显示不合格标志
//return;
}
//第三步,用于工件离开后完工数量统计及工件编号追溯
//BaseDataSystemMES.MaterialPush_EngineIDStatus_Insert(OpName);//更新订单产量
//第四步,获取是否允许工作
BaseDataSystemMES.MesServer_Judge_IsCanWork(OpName, out IsAllowWork);
//暂时先定义为扫描完成才能进行压装工作,因为考虑到工作完成后,操作工未必会去扫描物料的情况
if (IsAllowWork == 1)
{
//通知PLC允许工作,允许工作在保存完成时清空
MIS_BASE.Write_FixAllow(OpName, true);
}
else
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "请扫描物料!");
}
}
/// <summary>
/// 二次工作
/// </summary>
/// <param name="OpName"></param>
private void EngineTypeGetOver_PLC_Work_two(string OpName)
{
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
EngineTypeGetOver_PLC_Work(OpName, EngineTypeID, EngineType, EngineID, Convert.ToInt32(PartPallet_Code), OrderForm);
}
/// <summary>
/// 跳过二次工作
/// </summary>
/// <param name="OpName"></param>
private void EngineTypeGetOver_PLC_Work_Skip(string OpName)
{
//MIS_BASE.Write_MesReadOver(OpName, true);
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
/// <summary>
/// 返修件需要工作
/// </summary>
/// <param name="OpName">工位号</param>
private void IsNeedRepaire_OK(string OpName)
{
string orderForm = "";
int engineTypeID;
string engineType = "";
string engineID = "";
string palletCode = "";
int isRepair;
string repairCode = "";
//从监控系统中查询出本工位信息
BaseDataSystemMES.OpName_MIS_Moby_Select(OpName,
out orderForm, out engineTypeID, out engineType,
out engineID, out palletCode, out isRepair, out repairCode);
EngineTypeGetOver_PLC_Work(OpName, engineTypeID, engineType, engineID, Convert.ToInt32(palletCode),orderForm);
}
}
}

View File

@@ -0,0 +1,127 @@
using System;
using bizFacade;
//using SystemFramework;
namespace MesServerFunctions
{
/// <summary>
/// 此类用于向WEB发送各种类型消息
/// </summary>
partial class FunctionMES
{
/// <summary>
/// 批量发送WEB消息Value为BOOL值
/// </summary>
/// <param name="MessageNumm">消息编号组合</param>
/// <param name="Value">消息值组合</param>
/// <param name="OpName">工位号</param>
void Sendmessage(string MessageNumm,string Value, string OpName)
{
for (int i=0;i<MessageNumm.Length;i++)
{
Sendmessage(MessageNumm[i], Value[i].ToString(), OpName);
}
}
/// <summary>
/// 选择发送给WEB的消息
/// </summary>
/// <param name="Num">消息类型</param>
/// <param name="OpName">消息工位</param>
string Sendmessage(char Num,string Value, string OpName)
{
string SendMessage;
string result = "";
switch (Num)
{
case '1':
//1直接在界面通过选择机型确认工序内容
SendMessage = "MES|ProcessList|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '2':
//2显示物料
SendMessage = "MES|MaterialList|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '3':
//3显示操作指导图片
SendMessage = "MES|PicShow|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '4':
//4订单完工模块刷新完成数量
SendMessage = "MES|OrderFormList|" + OpName + "|" + Value;
AsyncSendMessage(SendMessage);
break;
case '5':
SendMessage = "MES|ShowMoby|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '6':
SendMessage = "MES|MaterialCheckPosition|" + OpName + "|" +Value;
result = AsyncSendMessage(SendMessage);
break;
case '7':
SendMessage = "MES|WorkStart|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '8'://清除MES生成编号
break;
case '9':
SendMessage = "MES|ConfirmOkGo|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case 'a':
SendMessage = "MES|FixAllow|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
}
return result;
}
/// <summary>
/// 向WEB发送信息value为字符串
/// </summary>
/// <param name="Command">消息种类</param>
/// <param name="Value">消息内容</param>
/// <param name="OpName">工位号</param>
string SendInfomation(string Command, string Value, string OpName)
{
string SendMessage = "MES|" + Command + "|" + OpName + "|" + Value;
return AsyncSendMessage(SendMessage);
}
/// <summary>
/// 发送在线产量、在线节拍
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void SendActuallyCount(string OpName, int tagValue)
{
//当工件离开时,更新在线产量、在线节拍
if (tagValue == 0)
{
try
{
int opNameCount = 0;//在线产量
int opNameCountTime = 0;//在线节拍
//基本数据_工作日历_班次产量查询_New
BaseDataSystemMES.OpNameCount_New(OpName, out opNameCount, out opNameCountTime);
string SendMessage;
SendMessage = "MES|ActuallyCount|" + OpName + "|" + opNameCount.ToString() + "&" + opNameCountTime.ToString();
AsyncSendMessage(SendMessage);
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:SendActuallyCount");
}
}
}
}
}

View File

@@ -0,0 +1,53 @@
using bizFacade;
//using SystemFramework;
using MesServerWork;
using DataLinkMesWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 发送信息到MES通讯服务器或者其他的
/// </summary>
/// <param name="Message"></param>
private string AsyncSendMessage(string Message)
{
return MIS_BASE.asyncSendMessage(Message);
}
/// <summary>
/// 发送提示消息
/// </summary>
/// <param name="Message"></param>
private void AsyncSendMessage_Notice(string opname, string notice)
{
//通知Web界面
BaseDataSystemMES.Web_Notice_Insert(opname, notice);
string SendMessage = "MES|Notice|" + opname + "|" + "1";
MIS_BASE.asyncSendMessage(SendMessage);
}
/// <summary>
/// 发送信息到打印机
/// </summary>
/// <param name="Message"></param>
private void asyncSendMessageToMark(string Message)
{
string messageSend = (string)Message;
//UDPClientSend.Send_ALL(ApplicationConfig.MES_MarkPortNum, messageSend);
}
/// <summary>
/// 发送信息到LED
/// </summary>
/// <param name="Message"></param>
private void asyncSendMessageLED(string OpName)
{
//发送到大屏幕显示 41104
string strMessage = "MIS|" + OpName + "|" + "0" + "|" + "1";
//UDPClientSend.Send_ALL(ApplicationConfig.Port_ShowLED_ProductCount, strMessage);
}
}
}

View File

@@ -0,0 +1,109 @@
using System;
using System.Data;
using System.Windows.Forms;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
///1.扫描配送单号用于接收物料扫描单号的时候将接收的物料信息显示在“物料拉动”Tab区域
///2.扫描料箱标签/看板卡,用于追溯物料批次信息
///3.扫描零件条码,根据零件图号进行防错
///第一步,判断条码类型,根据条码类型,执行对应的存储过程
///第二步,条码类型(将扫描的条码保存到对应的表中)
///第三步,扫描完成之后给出允许工作信号
/// 处理页面扫描条码
/// </summary>
/// <param name="OpName"></param>
/// <param name="barcode"></param>
public void Barcode(object e)
{
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
string barcode = Convert.ToString(msgEvent.TagValue);
SendMessageFun.SendInfomation("BarCodeData", barcode, OpName); // 将扫码值发送给前端
string AlarmStr = "";
bool isShowBarNGTipBox;
int IsAllowWork;
bool IsSuccess = false;
bool EngineGetOver_PLC_NextWorkStep;
// 判断是否存在异常导致不允许工作 输出msg到前端
DataTable OpNameIsWorkDt = BaseDataSystemMES.OpNameIsAllowWork(OpName);
if (Convert.ToInt32(OpNameIsWorkDt.Rows[0]["提示类型"]) == 3)
{
SendMessageFun.SendInfomation("ShowTipBox", OpNameIsWorkDt.Rows[0]["提示文本"].ToString(), OpName);
return;
}
//传递机型是否到位
MIS_BASE.Read_EngineGetOver_PLC(OpName, out EngineGetOver_PLC_NextWorkStep);
if (!EngineGetOver_PLC_NextWorkStep)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "PLC未传递机型");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描条码失败,请检查扫码位置是否正确!", OpName);
return;
}
//物料验证
BaseDataSystemMES.PartMaterial_DM_Update(OpName, barcode, out IsSuccess);
if (!IsSuccess)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "条码无效,请确认");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描条码失败,请检查扫码位置是否正确!", OpName);
return;
}
else
{
SendMessageFun.SendInfomation("MaterialList", "1", OpName);//通知界面更新零件信息
}
//获取是否允许工作
BaseDataSystemMES.MesServer_Judge_IsCanWork(OpName, out IsAllowWork);
//此处逻辑有问题 需要考虑到批次扫描 提示PLC未传递机型的情况
if (IsAllowWork == 1)
{
//更新订单完工数量及物料
SendMessageFun.SendMessage("24", "11", OpName);
//通知PLC允许工作,允许工作在保存完成时清空
MIS_BASE.Write_FixAllow(OpName, true);
SendMessageFun.AsyncSendMessage_Notice(OpName, "扫码完成,请开始工作!");
BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 2);
}
else
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "请扫描物料!");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描条码失败,请检查扫码位置是否正确!", OpName);
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(4, e, "Fun1053", err);
////ApplicationLog.WriteLog(err, "Function02:Barcode");
}
}
}
}
}

View File

@@ -0,0 +1,41 @@
using System;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void ConfirmOkGo(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
//BaseDataSystemMES.Material_Insert(OpName, 1);
////更新订单完工数量及物料
//Sendmessage("24", "11", OpName);
////工作完成
//MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:ConfirmOkGo");
}
}
}
}

View File

@@ -0,0 +1,108 @@
using System;
using System.Data;
using System.Windows.Forms;
using System.Xml.Linq;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// PLC传递机型处理
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void EngineTypeGetOver_PLC(object e)
{
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
string OrderForm_MES;
int EngineTypeID_MES;//机型代码
string EngineType_MES;//机型
string EngineID_MES;//工件编号
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
MIS_BASE.GetEngineTypeFromPLC_MES(OpName, out EngineTypeID_MES, out EngineType_MES, out EngineID_MES, out OrderForm_MES);
// 测试的时候用的 plc读取订单号有问题
// OrderForm = BaseDataSystemMES.GetOrderDataBySn(EngineID);
// 判断是否存在异常导致不允许工作 输出msg到前端
DataTable OpNameIsWorkDt = BaseDataSystemMES.OpNameIsAllowWork(OpName);
if (Convert.ToInt32(OpNameIsWorkDt.Rows[0]["提示类型"]) == 3)
{
SendMessageFun.SendInfomation("ShowTipBox", OpNameIsWorkDt.Rows[0]["提示文本"].ToString(), OpName);
return;
}
if ( EngineID_MES == EngineID & EngineType_MES == EngineType)
{
DataTable dt;
dt = BaseDataSystemMES.EngineTypeChange(OpName, EngineType);
//提示机型发生变化
if (dt.Rows.Count > 0)
{
string mesValue = Newtonsoft.Json.JsonConvert.SerializeObject(dt);//<DoWhatPlc.CustomeEvetnArgs>(recData);
string message = "MES|MaterialList_Dif_Resources|" + OpName + "|" + mesValue;
SendMessage.AsyncSendMessage(message);
}
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineTypeID, EngineTypeID.ToString());
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineType, EngineType);
if ((OpName == "J07PA040" && Convert.ToBoolean(MIS_BASE.ReadPLC(64, OpName))) || OpName == "J07PA030")
{
// 在保存后才将托盘号置位为1
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID, EngineID+"-2");
}
else
{
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID, EngineID);
}
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.OrderForm, OrderForm);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.PartPallet_Code, PartPallet_Code.ToString());
//显示当前订单信息
SendMessage.ShowMoby(OpName);
EngineTypeGetOver_PLC_Work(OpName, EngineTypeID, EngineType, EngineID, PartPallet_Code, OrderForm);
}
else
{
SendMessage.AsyncSendMessage_Notice(OpName, "PLC机型与MES机型不匹配");
}
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(2, e, "Fun1053", err);
////ApplicationLog.WriteLog(err, "Function02:EngineTypeGetOver_PLC");
}
}
}
}
}

View File

@@ -0,0 +1,41 @@
using System;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 不合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void FalseGO(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
//总合格标志2不合格
//BaseDataSystemMES.Material_Insert_NG(OpName, 2);
//Sendmessage("24", "11", OpName);
////工作完成
//MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,66 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// MES与PLC心跳监听
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void HeartBeat(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
//返写在MES心跳中
//MIS_BASE.WritePLC(15, OpName, tagValue);
// 获取登录状态
//if (tagValue == 1)
//{
//DataTable tempDt;
//BaseDataSystemMES.Get_TempData(OpName, "登陆状态", out tempDt);
//if (tempDt.Rows.Count > 0) MIS_BASE.WritePLC(54, OpName, tempDt.Rows[0]["数值"]);
//}
//PA010 需要将当前选中订单的状态发送给PLC
if (OpName == "J07PA010")
{
DataTable workDt;
BaseDataSystemMES.Get_NowWorkOrder(OpName, out workDt);
// 获取数据 判断有没有条数 没有就全置0 有的话根据机型给 71 5s 72 6s
MIS_BASE.WritePLC(71, OpName, false);
MIS_BASE.WritePLC(72, OpName, false);
if (workDt.Rows.Count > 0)
{
if (Convert.ToInt32(workDt.Rows[0]["机型代码"]) == 1 || Convert.ToInt32(workDt.Rows[0]["机型代码"]) == 2)
{
// 5s
MIS_BASE.WritePLC(71, OpName, true);
}
else
{
MIS_BASE.WritePLC(72, OpName, true);
}
}
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,135 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
// 触发J07PA010流程
private void J07PA010WorkStart(object e)
{
{
try
{
int EngineTypeID;
string EngineType;
string EngineID;
int PartPallet_Code;
string OrderForm;
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
int tagTypeID = Convert.ToInt32(msgEvent.TagTypeID); // 1. 计数1 2.计数2
int TagTypeCodeID = Convert.ToInt32(msgEvent.TagTypeCodeID); // 报警点位置
//25 ~34 10个地址
//25 26 27 为6s 触发
//28 29 为5s触发
//30 31 32 为6s报警
//33 34 5s报警
// 35 5S 3 触发
// 36 5S 3 报警
if (tagValue == 1)
{
List<int> errorPositonList = new List<int> {30,31,32,33,34,36};
for (int i = 0;i < errorPositonList.Count; i++) {
int itemErrorPositon = errorPositonList[i];
MIS_BASE.WritePLC(itemErrorPositon, OpName, false); // 清空报警信号
}
// 只用于PA010工位的逻辑循环
// 1.将报警变量置位为0
// 2.判断当前有没有选择订单号 若没有选择订单号则不工作,提示选择订单号
// 只需要 订单号,总成号,机型号 托盘编号为0
//北汽福田工位状态监控MOBY_查询_订单下达用
DataTable dt;
dt = BaseDataSystemMES.GetNowWorkOrderData(OpName, tagTypeID);
if(dt.Rows.Count > 0)
{
EngineTypeID = Convert.ToInt32(dt.Rows[0]["机型代码"]);
EngineType = dt.Rows[0]["零件号"].ToString();
EngineID = dt.Rows[0]["变速箱总成号"].ToString();
OrderForm = dt.Rows[0]["订单号"].ToString();
// 如果有订单但按钮按的位置与机型对不上则退出方法
if(EngineTypeID == 1 || EngineTypeID == 2)
{
if(TagTypeCodeID != 33 && TagTypeCodeID != 34 && TagTypeCodeID != 36)
{
SendMessage.AsyncSendMessage_Notice(OpName, "请选择与机型相对应的按钮进行操作!");
return;
}
}
// 如果有订单但按钮按的位置与机型对不上则退出方法
if (EngineTypeID == 4 || EngineTypeID == 8)
{
if (TagTypeCodeID != 30 && TagTypeCodeID != 31 && TagTypeCodeID != 32)
{
SendMessage.AsyncSendMessage_Notice(OpName, "请选择与机型相对应的按钮进行操作!");
return;
}
}
////将产品信息写入PLC
MIS_BASE.Write_EngineTypeID_MES(OpName, EngineTypeID);
MIS_BASE.Write_EngineType_MES(OpName, EngineType);
MIS_BASE.Write_EngineID_MES(OpName, EngineID);
MIS_BASE.Write_OrderForm_MES(OpName, OrderForm);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStartIn, DateTime.Now.ToString());
// 将数据保存到监控MOBY中
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineType, EngineType);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID, EngineID);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.OrderForm, OrderForm);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.PartPallet_Code, tagTypeID.ToString());
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID_MES, EngineID);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineType_MES, EngineType);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.OrderForm_MES, OrderForm);
//电子看板_装配零件_临时表_增加_北汽
//第二步将零件信息转移到零件_临时表中
BaseDataSystemMES.MesServer_Process_EngineTypeOverBQ(OpName);
// 4.将这些数据推送到前端进行显示
//显示当前订单信息
SendMessage.ShowMoby(OpName);
SendMessageFun.SendMessage("12345", "11111", OpName);
// 5.保存过站数据
//测量数据发动机在线状态
BaseDataSystemMES.WorkStartInsert(OpName, 1);
// 6.该订单计数加一
BaseDataSystemMES.newAddOrderCount(OpName, EngineID, OrderForm, tagTypeID);
// 7.发送保存完成信号,结束本次循环
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStartOut, DateTime.Now.ToString());
SendMessageFun.SendInfomation("FlushOverWorkList", "1", OpName);
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
else
{
MIS_BASE.WritePLC(TagTypeCodeID, OpName, true); // 计数12是否超过条码数 超过发1退出循环给PLC信号
SendMessage.AsyncSendMessage_Notice(OpName, "该订单已生产完毕或无选中的生产订单,请选择其他订单进行生产!");
return;
}
}
else
{
MIS_BASE.Write_MaterialVerifyOver(OpName, false);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function08:MesReadOver");
}
}
}
}
}

View File

@@ -0,0 +1,99 @@
using bizFacade;
using MesServerWork;
using System;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 允许保存(针对半自动和手动压装工位)
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void MesRead(object e)
{
{
try
{
int EngineTypeID;
string EngineType;
string EngineID;
int PartPallet_Code;
string OrderForm;
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
//保存数据到线首表 先保存到 北汽福田变速器序列号总线上线 用于之前判断是否重号
if (Db.UpLoadOpNameInsert(EngineID, EngineTypeID, EngineType, OpName))
{
//保存质量数据
int qualityMask = MisDataSaveDateMesRead.Funtion.MesRead(OpName, tagValue.ToString(), msgEvent.TagID.ToString());
//保存物料数据
BaseDataSystemMES.Material_Insert(OpName, qualityMask);
//保存过站数据
BaseDataSystemMES.WorkStartInsert(OpName, qualityMask);
// 是否二次工作
int isTowWork = 0;
if (OpName == "J07PA040")
{
isTowWork = Convert.ToInt32(MIS_BASE.ReadPLC(64, OpName));
}
// 根据二次压装来判断计数编号是哪个
// 6.该订单计数加一
BaseDataSystemMES.newAddOrderCount(OpName, EngineID, OrderForm, isTowWork);
SendMessageFun.SendInfomation("FlushOverWorkList", "1", OpName);
// 是否为5s工件 5s走二次压装
bool is5SWork = false;
if (EngineTypeID == 2 || EngineTypeID == 4) is5SWork = true;
//// 只有PA020 与 PA040 的5s 一次压装 不设为1
//if (OpName != "J07PA020" && !(OpName == "J07PA040" && isTowWork == 0 && is5SWork))
//{
// // 在保存后才将托盘号置位为1
// BaseDataSystemMES.Set_TrayID(OpName, EngineID+"-2");
// // 同时将对于上一个设备将其托盘号设为1
// BaseDataSystemMES.Set_TrayID(OpName, EngineID);
// //BaseDataSystemMES.Set_TrayIDByBackWork(OpName, EngineID);
//}
//推送质量数据到MES的页面
SendMessageFun.SendInfomation("ShowTimelyQuality", "1&" + qualityMask.ToString(), OpName);
//统计在线产量,在线节拍
SendMessage.SendActuallyCount(OpName, tagValue);
//通知设备MES的质量数据和物料数据保存完成
MIS_BASE.Write_MesReadOver(OpName, true);
//MES工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
else
{
SendMessage.AsyncSendMessage_Notice(OpName, "保存上线数据失败!");
}
}
else
{
MIS_BASE.Write_MesReadOver(OpName, false);
}
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(3, e, "Fun1053", err);
////ApplicationLog.WriteLog(err, "Function08:MesReadOver");
}
}
}
}
}

View File

@@ -0,0 +1,55 @@
using System;
//using SystemFramework;
using MesServerWork;
using bizFacade;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 保存完成(针对半自动和手动压装工位)
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void MesReadOver(object e)
{
//try
//{
// DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
// string OpName = Convert.ToString(msgEvent.OpName);
// var tagValue = msgEvent.TagValue.ToString ();
// if (tagValue == "1" | tagValue.ToLower () == "true")
// {
// int qualityMask;
// MIS_BASE.Read_QualityMask(OpName, out qualityMask);
// SendInfomation("ShowTimelyQuality", "1&" + qualityMask.ToString(), OpName);//发给Web页面显示质量数据
// if (qualityMask == 1)//全部OK给出合格放行
// {
// //如果存在线外扫描工位,根据扫描条码绑定线外数据 需要时解除禁用
// //BaseDataSystemMES.TransLaunchDataByMainMaterial(OpName, EngineType, EngineID, EngineTypeID);
// //如果存在线外排队工位,根据排队编号绑定线外数据 需要时解除禁用
// ////BaseDataSystemMES.MailLineAndSubLineData_InsertByEngineID_Subline(OpName,EngineID, EngineTypeID, EngineType);
// MIS_BASE.Write_ConfirmOkGo(OpName, true);
// //MIS_BASE.Write_FalseGO(OpName, false);
// }
// else
// {
// //MIS_BASE.Write_ConfirmOkGo(OpName, false);
// MIS_BASE.Write_FalseGO(OpName, true);
// }
// }
//}
//catch (Exception err)
//{
// ////ApplicationLog.WriteLog(err, "Function02:MesReadOver");
//}
}
}
}

View File

@@ -0,0 +1,43 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using static System.Net.Mime.MediaTypeNames;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// MES保存实时质量数据
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void MesSaveNowData(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
// 直接发送实时的 质量数据
string message = MisDataSaveDateMesRead.Funtion.GetRealTimeQualityData(OpName);
//推送质量数据到MES的页面
SendMessage.AsyncSendMessage("MES|ShowTimelyQuality_Resources|" + OpName + "|" + message);
//SendMessageFun.SendMessageMESToWEB("ShowTimelyQuality", "1&" + qualityMask.ToString(), OpName);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,187 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading;
using System.Threading.Tasks;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 申请上线 43
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void PartLoad(object e)
{
try
{
int EngineTypeID;//机型代码
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
int PLCRcipe;
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
//+*************DbName*****************
string DbName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
int workGetOrderType = 0;
if (tagValue > 0)
{
// 是否为二次压装
if(OpName == "J07PA040")
{
if (Convert.ToBoolean(MIS_BASE.ReadPLC(64, OpName)))
{
workGetOrderType = 1;
}
}
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStartIn, DateTime.Now.ToString());
//开始上线前清空交互区数据
MIS_BASE.Write_MesReadOver(OpName, false);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
MIS_BASE.Write_EngineTypeGetOver_MES(OpName, false);
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, false);
//工作类型 0 正常件 1 PA30 件 2 PA40 返回件
//int workType = 0;
//if (OpName == "J07PA030")
//{
// //该工件是PA30工件
// workType = 1;
//}
////判断 是否为二次加工件 64
//if (OpName == "J07PA040" && workGetOrderType == 1)
//{
// //该工件是PA40二次加工件
// workType = 2;
//}
//if (workType == 0)
//{
// 正常逻辑 获得机型信息、配方号
//获取到的5s 6s 工件条码
//北汽福田工位状态监控MOBY_查询_订单下达用
DataTable dt;
dt = BaseDataSystemMES.GetNowWorkOrderData(OpName, workGetOrderType);
if(dt.Rows.Count > 0)
{
if (Convert.ToInt32(dt.Rows[0]["线首是否完成工作"]) == 4)
{
MIS_BASE.WritePLC(32, OpName, true);
SendMessage.AsyncSendMessage_Notice(OpName, "该订单所有总成号已在MA010工作完毕不允许继续工作请联系班长进行修改完工状态");
return;
}
else
{
EngineTypeID = Convert.ToInt32(dt.Rows[0]["机型代码"]);
EngineType = dt.Rows[0]["零件号"].ToString();
EngineID = dt.Rows[0]["变速箱总成号"].ToString();
OrderForm = dt.Rows[0]["订单号"].ToString();
MIS_BASE.WritePLC(32, OpName, false);
}
}
else
{
MIS_BASE.WritePLC(32, OpName, true);
SendMessage.AsyncSendMessage_Notice(OpName, "该订单已生产完毕或无选中的生产订单,请选择其他订单进行生产!");
return;
}
//}
//else
//{
// DataTable dt2;
// if (workType == 1)
// {
// // PA30逻辑 从PA20获得机型信息、配方号、
// dt2 = BaseDataSystemMES.lineOutTowBackWork_GetData("J07PA020", 1);
// }
// else //workType == 2
// {
// // PA40Back逻辑 从PA40获得机型信息、配方号、
// dt2 = BaseDataSystemMES.lineOutTowBackWork_GetData("J07PA040", 0);
// }
// EngineTypeID = Convert.ToInt32(dt2.Rows[0]["机型代码"]);
// //配方号暂时没保存
// EngineType = dt2.Rows[0]["机型"].ToString();
// OrderForm = dt2.Rows[0]["订单号"].ToString();
// EngineID = dt2.Rows[0]["总成号"].ToString();
//}
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID_MES, EngineID);
// 将产品信息写入PLC
MIS_BASE.Write_EngineTypeID_MES(OpName, EngineTypeID);
MIS_BASE.Write_EngineType_MES(OpName, EngineType);
MIS_BASE.Write_EngineID_MES(OpName, EngineID);
MIS_BASE.Write_OrderForm_MES(OpName, OrderForm);
// 获得配方数据
//BaseDataSystemMES.PLCRcipeByOpName(OpName, out byte[] bytes, out string tagStartAdr, PLCRcipe);
// 写入配方数据
//DtWebApi.ReadWritePLC.Write_TagValueByTagTypeID("94", OpName, System.Text.Encoding.ASCII.GetString(bytes));
// MES传递机型
MIS_BASE.Write_EngineTypeGetOver_MES(OpName, true);
}
else
{
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStartOut, DateTime.Now.ToString());
MIS_BASE.Write_MesReadOver(OpName, false);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
MIS_BASE.Write_EngineTypeGetOver_MES(OpName, false);
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, false);
//清除上线信息
MIS_BASE.Write_EngineTypeID_MES(OpName, 0);
MIS_BASE.Write_EngineType_MES(OpName, "");
MIS_BASE.Write_EngineID_MES(OpName, "");
MIS_BASE.Write_OrderForm_MES(OpName, "");
MIS_BASE.WritePLC(115, OpName, "");
//空挡开关检测
MIS_BASE.WritePLC(95, OpName, 0);
//倒挡开关检测
MIS_BASE.WritePLC(96, OpName, 0);
//里程表检测
MIS_BASE.WritePLC(97, OpName, 0);
//大机型扩展
MIS_BASE.WritePLC(98, OpName, 0);
//TCU
MIS_BASE.WritePLC(122, OpName, 0);
//注油量
MIS_BASE.WritePLC(123, OpName, 0);
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(1, e, "Fun1053", err);
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,357 @@
using System;
using MesServerWork;
using bizFacade;
using System.Threading;
using MisDataSaveDate;
using System.Collections;
using System.Data;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 处理WEB页面发送过来的请求m_Command + "|" + m_Value;
/// </summary>
/// <param name="OpName"></param>
/// <param name="Content"></param>
private void WebSubmit(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName=Convert.ToString(msgEvent.OpName);
string Content = Convert.ToString(msgEvent.TagValue);
string[] dataArray = Content.Split('|');
if (dataArray.Length != 2)
return;
//消息类型
string m_Command = dataArray[0].ToString();
//消息参数
string m_Value = dataArray[1].ToString();
//消息参数数量
string[] m_Value_array = m_Value.Split('&');
//消息参数长度
int m_Value_length = m_Value_array.Length;
//工件信息
string engineID = "";
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName))
{
engineID = MIS_BASE.hashtable_EngineGetOver_EngineID[OpName].ToString();
}
DoWhatPlc.CustomeEvetnArgs _e = new DoWhatPlc.CustomeEvetnArgs();
_e.OpName = OpName;
_e.TagValue = m_Value;
//根据请求的命令处理逻辑
switch (m_Command)
{
case "Barcode":
if (m_Value_length > 1) return;
fun_Barcode(_e);
break;
case "ConfirmOkGo"://合格放行
//删除不合格放行记录
//修改托盘状态
//Update_PalletStatus(OpName, 1, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_ConfirmOkGo(OpName, true);
MIS_BASE.Write_FalseGO(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
break;
case "FalseGO"://返修放行
//修改托盘状态
//Update_PalletStatus(OpName, 3, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "NgGO"://不合格放行
//修改托盘状态
//Update_PalletStatus(OpName, 2, false);
//保存不合格信息(必须保存不合格放行信息由于B5A的Moby没有不合格标志位)
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Insert(OpName, engineID, "", "");
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "OnLineState"://在线0、离线1、屏蔽2
try
{
if (m_Value_length > 1) return;
int a = Convert.ToInt32(m_Value);
if (a <= 2)
{
BaseDataSystemMES.IsOnLine_Update(OpName, m_Value.ToString());
MIS_BASE.Write_OnLineState(OpName, Convert.ToInt32(m_Value));
if (a == 2) SendMessage.AsyncSendMessage_Notice(OpName, "屏蔽MES");
if (a == 0) SendMessage.AsyncSendMessage_Notice(OpName, "启用MES");
}
}
catch
{
}
break;
case "Reset"://复位将MES所有的信息都复位了
SetMoby(OpName);//将MES所有信号清空
break;
case "FixAllow"://重新拧紧
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_FixAllow(OpName, true);
break;
case "IsAutoGetEngineID"://自动手动申请编号(线首)
if (m_Value_length > 1) return;
MIS_BASE.Write_IsAutoGetEngineID(OpName, Convert.ToInt32(m_Value));
break;
case "PartPalletGoOver"://空托盘放行
int Is_PartPalletGoOver;
MIS_BASE.Read_PartPalletGoOver(OpName, out Is_PartPalletGoOver);
if (Is_PartPalletGoOver == 1)
{
MIS_BASE.Write_PartPalletGoOver(OpName, 1);
}
else
{
MIS_BASE.Write_PartPalletGoOver(OpName,0);
}
break;
case "SetMoby"://清空托盘(线首)
SetMoby(OpName);//将MES所有信号清空
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "RepairUplineMES"://返修上线
MIS_BASE.Write_RepairUpline_MES(OpName, true);
break;
case "CancelRepair"://将返修件置为正常件
break;
case "PartPalletCode"://申请写入托盘号
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "WritePartPalletCode"://写入托盘号
if (m_Value_length > 1) return;
MIS_BASE.Write_PalletCode(OpName, Convert.ToInt32(m_Value));
break;
case "Normal"://启用正常拧紧工位
MIS_BASE.Write_Normal(OpName, 1);
MIS_BASE.Write_UnNormal(OpName, 0);
break;
case "UnNormal"://启用备用拧紧工位
MIS_BASE.Write_Normal(OpName, 0);
MIS_BASE.Write_UnNormal(OpName, 1);
break;
case "ResetDevice"://复位设备
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
break;
case "IsNeedRepaire"://返修上线(返修上线点)
if (Convert.ToInt32(m_Value) == 1)
{
//修改托盘状态
MIS_BASE.Write_PalletInfo(OpName, 3);
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
IsNeedRepaire_OK(OpName);
}
else if (Convert.ToInt32(m_Value) == 0)
{
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
//直接给出工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
else
{ }
break;
case "ContinueMatch":
BaseDataSystemMES.QualityVerifyStatus_Hash_Write(OpName, true);
break;
//初始化网页信号
case "IniSingalToWeb":
InitializeSingalToWeb(OpName);
break;
case "Reset_Engine"://返修上线(返修上线点)
SetMoby(OpName);//将MES所有信号清空
//fun_EngineTypeGetOverPLC(OpName, 0);
//fun_EngineTypeGetOverPLC(OpName, 1);
break;
case "twoWorkSkip"://重新工作工件跳过工作(重新工作工件)
//工作完成
EngineTypeGetOver_PLC_Work_Skip(OpName);
break;
case "twoWork"://重新工作工件重新工作(重新工作工件)
//允许工作
EngineTypeGetOver_PLC_Work_two(OpName);
break;
case "FaultBackWork"://返修工件
// 写入地址
MIS_BASE.WritePLC(33, OpName, true);
Thread.Sleep(1000);
MIS_BASE.WritePLC(33, OpName, false);
break;
case "remedyWork"://补拧工件
// 接受传来的补拧程序号 补拧数量 拆分
string[] arr = m_Value.ToString().Split('&');
string codeNumber = arr[0];
string workCount = arr[1];
// 写入地址 在工件离开后清空
MIS_BASE.WritePLC(77, OpName, codeNumber);
MIS_BASE.WritePLC(88, OpName, workCount);
// 若这个点被置0了说明PLC那补拧结束了
MIS_BASE.WritePLC(30, OpName, true);
break;
case "remedyWorkEnd"://补拧工件
MIS_BASE.WritePLC(77, OpName, 0);
MIS_BASE.WritePLC(88, OpName, 0);
MIS_BASE.WritePLC(30, OpName, false);
break;
case "closeWebWindow":// 前端窗口关闭
// 将持久化存储表中工位的登陆状态设置为接受值
BaseDataSystemMES.Set_TempData(OpName, "登陆状态", m_Value);
MIS_BASE.WritePLC(54, OpName, false);
break;
case "QuitEngineTypeCheck":// 发送给服务器换型请求,等待服务器换型判断发送到页面端
DataTable dt;
dt = BaseDataSystemMES.EngineTypeChange(OpName, m_Value);
//提示机型发生变化
if (dt.Rows.Count > 0)
{
string mesValue = Newtonsoft.Json.JsonConvert.SerializeObject(dt);//<DoWhatPlc.CustomeEvetnArgs>(recData);
string message = "MES|MaterialList_Dif_Resources|" + OpName + "|" + mesValue;
SendMessage.AsyncSendMessage(message);
// 写入MOBY 写入机型信息与清空总成号
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineType, mesValue);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID, "");
//通知web显示
SendMessageFun.SendMessage("5", "1", OpName);
}
break;
default: break;
}
}
catch(Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:WebSubmit");
}
}
private void SetMoby(string OpName)
{
try
{
//清空Moby时需要将MES信号清空
MIS_BASE.Write_ClearMesMoby(OpName);
BaseDataSystemMES.MesServer_Process_EngineTypeOver(OpName);
Sendmessage("5123", "1111", OpName);
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
}
catch
{
}
}
/// 网页重现登录,恢复关闭前的页面状态
/// </summary>
/// <param name="Opname">工位号</param>
private void InitializeSingalToWeb(string Opname)
{
//工件到位 DBX0.1
bool S_WorkStart;
bool S_FixAllow;
bool S_EngineGetOver;
bool S_MaterialVerifyOver;
MIS_BASE.Read_WorkStart(Opname, out S_WorkStart);
MIS_BASE.Read_FixAllow(Opname, out S_FixAllow);
MIS_BASE.Read_EngineGetOver_PLC(Opname, out S_EngineGetOver);
MIS_BASE.Read_MaterialVerifyOver(Opname, out S_MaterialVerifyOver);
string S_plcStatus;//DBX501.5 PLC直通1 强制放行 0 正常循环
// 新增查询PLC直通状态 网页显示
MIS_BASE.Read_TagTypeID(63, Opname, out S_plcStatus);
if (Convert.ToInt32(S_plcStatus) == 0)
{
SendMessageFun.SendInfomation("PlcStatus", "0", Opname);
}
else
{
SendMessageFun.SendInfomation("PlcStatus", "1", Opname);
}
DataTable tempDt;
BaseDataSystemMES.Get_TempData(Opname, "登陆状态", out tempDt);
if (tempDt.Rows.Count > 0) MIS_BASE.WritePLC(54, Opname, tempDt.Rows[0]["数值"]);
Sendmessage("135", "1111", Opname);
// 查询螺丝号是否存在 存在则发送给前端
string CodeNumber;
MIS_BASE.Read_TagTypeID(125, Opname, out CodeNumber);
if (CodeNumber != "0")
{
SendMessageFun.SendInfomation("CodeNumber", CodeNumber,Opname);
}
// 查询螺丝号下拧紧排序是否存在 存在则发送给前端
string CodeNumberWorkNumber;
MIS_BASE.Read_TagTypeID(126, Opname, out CodeNumberWorkNumber);
if (CodeNumberWorkNumber != "0")
{
SendMessageFun.SendInfomation("CodeNumberWorkNumber", CodeNumberWorkNumber,Opname);
}
if (S_WorkStart == true)
{
SendInfomation("WorkStart", Convert.ToString(Convert.ToInt32(S_WorkStart)), Opname);
}
if (S_EngineGetOver == true)
{
SendInfomation("EngineTypeGetOverPLC", Convert.ToString(Convert.ToInt32(S_EngineGetOver)), Opname);
Sendmessage("2", "1111", Opname);
//SendMessage.ShowMoby(Opname);
}
if (S_FixAllow == true)
{
SendInfomation("FixAllow", Convert.ToString(Convert.ToInt32(S_FixAllow)), Opname);
}
if (S_MaterialVerifyOver == true)
{
SendInfomation("MaterialVerifyOver", Convert.ToString(Convert.ToInt32(S_MaterialVerifyOver)), Opname);
}
InitAlarm(Opname);
}
private void InitAlarm(string Opname)
{
FuntionMesRead.Alarm_InitAlarm_Send(Opname, out Hashtable ht);
foreach (DictionaryEntry kv in ht)
{
var TagID = kv.Key.ToString();
var TagValue = kv.Value.ToString();
FuntionMesRead.Send_AlarmMsg(TagID, TagValue);
}
}
}
}

View File

@@ -0,0 +1,45 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 工位合格标志
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void IsOk(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
int qualityMask;
MIS_BASE.Read_QualityMask(OpName, out qualityMask);
//判断是否合格
if (qualityMask == 1)
{
qualityMask = 1;
} else {
qualityMask = 0;
}
//通知WEB修改状态
string message = "MES|QualityMask|" + OpName + "|" + qualityMask.ToString();
SendMessage.AsyncSendMessage(message);
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,36 @@
using bizFacade;
using MesServerWork;
using System;
using System.Data;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 工件到位与离开时清空MES自身信号
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void WorkStart(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
for (int i = 1; i <= 40; i++)
{
MIS_BASE.WritePLC(127 + i, OpName, 0);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:WorkStart");
}
}
}
}

View File

@@ -0,0 +1,36 @@
using System.Reflection;
using System.Runtime.CompilerServices;
using System.Runtime.InteropServices;
// 有关程序集的常规信息通过以下
// 特性集控制。更改这些特性值可修改
// 与程序集关联的信息。
[assembly: AssemblyTitle("Function02")]
[assembly: AssemblyDescription("")]
[assembly: AssemblyConfiguration("")]
[assembly: AssemblyCompany("苏州宏软信息技术有限公司")]
[assembly: AssemblyProduct("Function02")]
[assembly: AssemblyCopyright("Copyright © 苏州宏软信息技术有限公司 2017")]
[assembly: AssemblyTrademark("")]
[assembly: AssemblyCulture("")]
// 将 ComVisible 设置为 false 使此程序集中的类型
// 对 COM 组件不可见。如果需要从 COM 访问此程序集中的类型,
// 则将该类型上的 ComVisible 特性设置为 true。
[assembly: ComVisible(false)]
// 如果此项目向 COM 公开,则下列 GUID 用于类型库的 ID
[assembly: Guid("47710f2c-e141-4252-8d13-701bf4c1c027")]
// 程序集的版本信息由下面四个值组成:
//
// 主版本
// 次版本
// 内部版本号
// 修订号
//
// 可以指定所有这些值,也可以使用“内部版本号”和“修订号”的默认值,
// 方法是按如下所示使用“*”:
// [assembly: AssemblyVersion("1.0.*")]
[assembly: AssemblyVersion("1.0.0.0")]
[assembly: AssemblyFileVersion("1.0.0.0")]

View File

@@ -0,0 +1,19 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<runtime>
<assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">
<dependentAssembly>
<assemblyIdentity name="Newtonsoft.Json" publicKeyToken="30ad4fe6b2a6aeed" culture="neutral"/>
<bindingRedirect oldVersion="0.0.0.0-13.0.0.0" newVersion="13.0.0.0"/>
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Net.Http" publicKeyToken="b03f5f7f11d50a3a" culture="neutral"/>
<bindingRedirect oldVersion="0.0.0.0-4.2.0.0" newVersion="4.2.0.0"/>
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="MQTTnet" publicKeyToken="b69712f52770c0a7" culture="neutral"/>
<bindingRedirect oldVersion="0.0.0.0-3.0.13.0" newVersion="3.0.13.0"/>
</dependentAssembly>
</assemblyBinding>
</runtime>
<startup><supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.8"/></startup></configuration>

View File

@@ -0,0 +1,5 @@
SCC = This is a Source Code Control file
[Function02.csproj]
SCC_Aux_Path = "\\192.168.0.100\vss\MES4.0"
SCC_Project_Name = "$/MisData/MisData/MisData/MesServer.Function/Function02", ILHAAAAA

View File

@@ -0,0 +1,15 @@
<?xml version="1.0" encoding="utf-8"?>
<packages>
<package id="Microsoft.NETCore.Platforms" version="1.1.0" targetFramework="net461" />
<package id="MQTTnet" version="3.0.13" targetFramework="net461" />
<package id="MQTTnet.Extensions.ManagedClient" version="3.0.13" targetFramework="net461" />
<package id="NETStandard.Library" version="2.0.0" targetFramework="net461" />
<package id="Newtonsoft.Json" version="13.0.1" targetFramework="net461" />
<package id="System.Net.Security" version="4.3.2" targetFramework="net461" />
<package id="System.Net.WebSockets" version="4.3.0" targetFramework="net461" />
<package id="System.Net.WebSockets.Client" version="4.3.2" targetFramework="net461" />
<package id="System.Security.Cryptography.Algorithms" version="4.3.0" targetFramework="net461" requireReinstallation="true" />
<package id="System.Security.Cryptography.Encoding" version="4.3.0" targetFramework="net461" />
<package id="System.Security.Cryptography.Primitives" version="4.3.0" targetFramework="net461" />
<package id="System.Security.Cryptography.X509Certificates" version="4.3.0" targetFramework="net461" />
</packages>