chore: 初始化北汽福田MES采集程序

This commit is contained in:
yexingqiang
2026-05-29 13:44:10 +08:00
commit c5e248e993
1399 changed files with 187196 additions and 0 deletions

View File

@@ -0,0 +1,15 @@
namespace MesServerFunctions
{
partial class Function1052
{
//针对“MIS.BizFacade.Dll”中没有的存储过程在此类中新建
//新建原则所有的函数用private,只允许在内部使用
//针对单个工艺特殊需要新建存储过程但是存储过程不能被加入到“MIS.BizFacade.Dll”中
private void aa()
{
}
}
}

View File

@@ -0,0 +1,10 @@
""
{
"FILE_VERSION" = "9237"
"ENLISTMENT_CHOICE" = "NEVER"
"PROJECT_FILE_RELATIVE_PATH" = "relative:MesServer.Function\\Function02"
"NUMBER_OF_EXCLUDED_FILES" = "0"
"ORIGINAL_PROJECT_FILE_PATH" = ""
"NUMBER_OF_NESTED_PROJECTS" = "0"
"SOURCE_CONTROL_SETTINGS_PROVIDER" = "PROVIDER"
}

View File

@@ -0,0 +1,169 @@
<?xml version="1.0" encoding="utf-8"?>
<Project ToolsVersion="12.0" DefaultTargets="Build" xmlns="http://schemas.microsoft.com/developer/msbuild/2003">
<PropertyGroup>
<Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration>
<Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform>
<ProductVersion>8.0.30703</ProductVersion>
<SchemaVersion>2.0</SchemaVersion>
<ProjectGuid>{5FEE5C91-8419-49FF-B2C2-47476F0B8C68}</ProjectGuid>
<OutputType>Library</OutputType>
<AppDesignerFolder>Properties</AppDesignerFolder>
<RootNamespace>Function1052</RootNamespace>
<AssemblyName>Function1052</AssemblyName>
<TargetFrameworkVersion>v4.8</TargetFrameworkVersion>
<FileAlignment>512</FileAlignment>
<SccProjectName>
</SccProjectName>
<SccLocalPath>
</SccLocalPath>
<SccAuxPath>
</SccAuxPath>
<SccProvider>
</SccProvider>
<TargetFrameworkProfile />
<NuGetPackageImportStamp>
</NuGetPackageImportStamp>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Debug|AnyCPU' ">
<DebugSymbols>true</DebugSymbols>
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>..\..\..\dll_fun\</OutputPath>
<DefineConstants>DEBUG;TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<UseVSHostingProcess>false</UseVSHostingProcess>
<Prefer32Bit>false</Prefer32Bit>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<Prefer32Bit>false</Prefer32Bit>
</PropertyGroup>
<ItemGroup>
<Reference Include="MQTTnet">
<HintPath>..\..\..\Common\dll\MQTTnet.dll</HintPath>
</Reference>
<Reference Include="MQTTnet.Extensions.ManagedClient">
<HintPath>..\..\..\Common\dll\MQTTnet.Extensions.ManagedClient.dll</HintPath>
</Reference>
<Reference Include="Newtonsoft.Json, Version=6.0.0.0, Culture=neutral, PublicKeyToken=30ad4fe6b2a6aeed, processorArchitecture=MSIL">
<SpecificVersion>False</SpecificVersion>
<HintPath>..\..\..\Common\dll\Newtonsoft.Json.dll</HintPath>
</Reference>
<Reference Include="System" />
<Reference Include="System.Core" />
<Reference Include="System.Drawing" />
<Reference Include="System.Net.Http">
<HintPath>..\..\DLL\System.Net.Http.dll</HintPath>
</Reference>
<Reference Include="System.Net.Security, Version=4.0.1.2, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Net.Security.4.3.2\lib\net46\System.Net.Security.dll</HintPath>
</Reference>
<Reference Include="System.Net.WebSockets, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Net.WebSockets.4.3.0\lib\net46\System.Net.WebSockets.dll</HintPath>
</Reference>
<Reference Include="System.Net.WebSockets.Client, Version=4.0.1.1, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Net.WebSockets.Client.4.3.2\lib\net46\System.Net.WebSockets.Client.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.Algorithms, Version=4.1.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.Algorithms.4.3.0\lib\net461\System.Security.Cryptography.Algorithms.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.Encoding, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.Encoding.4.3.0\lib\net46\System.Security.Cryptography.Encoding.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.Primitives, Version=4.0.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.Primitives.4.3.0\lib\net46\System.Security.Cryptography.Primitives.dll</HintPath>
</Reference>
<Reference Include="System.Security.Cryptography.X509Certificates, Version=4.1.1.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a, processorArchitecture=MSIL">
<HintPath>..\..\packages\System.Security.Cryptography.X509Certificates.4.3.0\lib\net461\System.Security.Cryptography.X509Certificates.dll</HintPath>
</Reference>
<Reference Include="System.Windows.Forms" />
<Reference Include="System.Xml.Linq" />
<Reference Include="System.Data.DataSetExtensions" />
<Reference Include="Microsoft.CSharp" />
<Reference Include="System.Data" />
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="Methods\EngineGetOverBaseWork.cs" />
<Compile Include="Methods\SubmitToMisweb.cs" />
<Compile Include="DataAccess\DataAccess.cs" />
<Compile Include="MesServerFunction\Fun_1052.cs" />
<Compile Include="Methods\UDP.Send.cs" />
<Compile Include="OpcServer\Barcode.cs" />
<Compile Include="OpcServer\ConfirmOkGo.cs" />
<Compile Include="OpcServer\EngineGetOver.cs" />
<Compile Include="OpcServer\FalseGO.cs" />
<Compile Include="OpcServer\MesSaveNowData.cs" />
<Compile Include="OpcServer\HeartBeat.cs" />
<Compile Include="OpcServer\MesRead.cs" />
<Compile Include="OpcServer\MesReadOver.cs" />
<Compile Include="OpcServer\WebSubmit.cs" />
<Compile Include="OpcServer\WorkStart.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
<Compile Include="OpcServer\WorkIsOk.cs" />
<Compile Include="SaveCode\SaveCode_J07MA080.cs" />
</ItemGroup>
<ItemGroup>
<None Include="app.config" />
<None Include="packages.config" />
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\..\..\Common\00MesWorkMqtt\MesWorkMqtt\00MesWorkMqtt.csproj">
<Project>{f55da1a0-a982-4479-8c47-0d9a5aaf3e18}</Project>
<Name>00MesWorkMqtt</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\01DoWhatPlc\01_01DoWhatPlc.csproj">
<Project>{0d1af432-439a-4920-8692-43ae139f5530}</Project>
<Name>01_01DoWhatPlc</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\02WebApiCall\02_02WebApiCallPLC.csproj">
<Project>{3e6d1dd5-01c9-435f-9941-61f906ce35bb}</Project>
<Name>02_02WebApiCallPLC</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\04DataBaseAccess\DataBaseAccess\04-DataBaseAccess.csproj">
<Project>{f434e066-4c59-47c8-aa82-6f48cc84501a}</Project>
<Name>04-DataBaseAccess</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\07WebBusinessFacade\BusinessFacade\07BusinessFacade.csproj">
<Project>{f0a0c525-03fd-428a-9b17-7f54aa0e4475}</Project>
<Name>07BusinessFacade</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\08WebFun_base\WebFun_base\08-WebFun_base.csproj">
<Project>{d98be764-adeb-488d-9714-61e308aa8201}</Project>
<Name>08-WebFun_base</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\Common\09MesDataFunction\MesDataFunction\09-MesDataFunction.csproj">
<Project>{90e76fb4-646d-45e2-95db-0b8ab4e465d6}</Project>
<Name>09-MesDataFunction</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\MisDataFun\SendMessageToWebMqtt\12SendMessageToWeb.csproj">
<Project>{e4eb6420-906d-4672-947a-ca33ddcdadfc}</Project>
<Name>12SendMessageToWeb</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\MIS_FuntionSaveData\MIS_FuntionSaveData\13.3MIS_FuntionSaveData.csproj">
<Project>{55b510c1-59e9-4bfd-ae84-d76d46f6e365}</Project>
<Name>02-13.3MIS_FuntionSaveData</Name>
</ProjectReference>
</ItemGroup>
<Import Project="$(MSBuildToolsPath)\Microsoft.CSharp.targets" />
<Import Project="..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets" Condition="Exists('..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets')" />
<Target Name="EnsureNuGetPackageBuildImports" BeforeTargets="PrepareForBuild">
<PropertyGroup>
<ErrorText>这台计算机上缺少此项目引用的 NuGet 程序包。使用“NuGet 程序包还原”可下载这些程序包。有关更多信息,请参见 http://go.microsoft.com/fwlink/?LinkID=322105。缺少的文件是 {0}。</ErrorText>
</PropertyGroup>
<Error Condition="!Exists('..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets')" Text="$([System.String]::Format('$(ErrorText)', '..\..\packages\NETStandard.Library.2.0.0\build\netstandard2.0\NETStandard.Library.targets'))" />
</Target>
<!-- To modify your build process, add your task inside one of the targets below and uncomment it.
Other similar extension points exist, see Microsoft.Common.targets.
<Target Name="BeforeBuild">
</Target>
<Target Name="AfterBuild">
</Target>
-->
</Project>

View File

@@ -0,0 +1,317 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Runtime.Remoting.Metadata.W3cXsd2001;
using System.Threading;
using System.Xml.Linq;
namespace MesServerFunctions
{
public partial class FunctionMES
{
object lockFunWork;
//public void FunWork(DoWhatPlc.CustomeEvetnArgs e)
public void FunWork(string recData)
{
lockFunWork = new object();
lock (lockFunWork)
{
List<string> dataArray = DoWhatPlc.MessageText.GetCmdStringList(recData);
//string[] dataArray = recData.Split('|');
//if (dataArray.Count != 4)
//return;
//消息来源
string m_Source = dataArray[0].ToString();
//消息类型 Barcode
string m_Command = dataArray[1].ToString();
//工位号
string m_OpName = dataArray[2].ToString();
//消息参数
string m_Value = dataArray[3].ToString();
DoWhatPlc.CustomeEvetnArgs e = new DoWhatPlc.CustomeEvetnArgs();// = Newtonsoft.Json.JsonConvert.DeserializeObject<DoWhatPlc.CustomeEvetnArgs>(m_Value);
string tagValue;
string strValue;
int intValue;
switch (m_Source)
{
case "BarCode":
e.OpName = m_OpName;
e.TagValue = m_Value;
fun_Barcode(e);
break;
case "WEB":
e.OpName = m_OpName;
e.TagValue = m_Command + "|" + m_Value;
fun_WebSubmit(e);
break;
case "PLC":
e = Newtonsoft.Json.JsonConvert.DeserializeObject<DoWhatPlc.CustomeEvetnArgs>(m_Value);
switch (e.TagValue.ToString().ToLower())
{
case "false":
tagValue = "0";
break;
case "true":
tagValue = "1";
break;
default:
tagValue = e.TagValue.ToString();
break;
}
e.TagValue = tagValue;
switch (e.TagTypeCodeID.ToString())
{
//PLC 工件到位
case "2":
fun_WorkStart(e);
break;
//PLC 允许保存质量数据
case "19":
fun_MesRead(e);
break;
//MES 保存数据完成
case "20":
fun_MesReadOver(e);
break;
//PLC 传递机型
case "44":
fun_EngineTypeGetOverPLC(e);
break;
//MES 合格放行
case "51":
fun_ConfirmOkGo(e);
break;
//MES 不合格放行
case "8":
fun_FalseGo(e);
break;
//PLC 工位合格标志
case "22":
fun_IsOk(e);
break;
//PLC 螺栓补拧结束
case "30":
int value = Convert.ToInt32(MIS_BASE.ReadPLC(30, m_OpName));
if (value == 0)
{
MIS_BASE.WritePLC(77, m_OpName, 0);
MIS_BASE.WritePLC(88, m_OpName, 0);
//先修改按钮显示
BaseDataSystemMES.SetButtomShouOrHide(m_OpName, "MES_BoltAddWorkStart", 1, 1, "MES_BoltAddWorkEnd", 0);
//通知前端刷新按钮
SendMessageFun.SendInfomation("SetButtomShouOrHide", "1", m_OpName);
}
break;
//PLC 螺栓抽检结束
case "31":
value = Convert.ToInt32(MIS_BASE.ReadPLC(31, m_OpName));
if (value == 0)
{
MIS_BASE.WritePLC(77, m_OpName, 0);
MIS_BASE.WritePLC(88, m_OpName, 0);
//先修改按钮显示
BaseDataSystemMES.SetButtomShouOrHide(m_OpName, "MES_BoltSpotCheckStart", 1, 1, "MES_BoltSpotCheckEnd", 0);
//通知前端刷新按钮
SendMessageFun.SendInfomation("SetButtomShouOrHide", "1", m_OpName);
}
break;
//PLC 监听铭牌打印结果
case "40":
strValue = MIS_BASE.ReadPLC(40, m_OpName).ToString();
//通知前端显示铭牌信息
if(m_OpName == "J07MA080")
{
SendMessageFun.SendInfomation("WatchMA080barCode", strValue, m_OpName);
}
break;
//MES保存实时质量数据
case "65":
fun_MesSaveNowData(e);
break;
//MES 系统健康心跳
case "14":
fun_HeartBeatMIS(e);
break;
case "63":
string S_plcStatus;//DBX501.5 PLC直通1 强制放行 0 正常循环
MIS_BASE.Read_TagTypeID(63, m_OpName, out S_plcStatus);
if (Convert.ToInt32(S_plcStatus) == 0)
{
SendMessageFun.SendInfomation("PlcStatus", "0", m_OpName);
}
else
{
SendMessageFun.SendInfomation("PlcStatus", "1", m_OpName);
}
break;
case "64":
// MA070确认返工 (501.6) 机动点,做特殊化操作
string S_plcBackGo;//DBX501.5 PLC直通1 强制放行 0 正常循环
MIS_BASE.Read_TagTypeID(64, m_OpName, out S_plcBackGo);
if (m_OpName == "J07MA070" || m_OpName == "J07ET030")
{
if (S_plcBackGo == "1")
{
SendMessageFun.SendInfomation("ShowBackWorkBox", "1", m_OpName);
}
else
{
SendMessageFun.SendInfomation("ShowBackWorkBox", "0", m_OpName);
}
}
if (m_OpName == "J07MA050")
{
if (Convert.ToBoolean(S_plcBackGo))
{
SendMessageFun.SendInfomation("ShowTipBox", "吊耳未装配,或传感器未刷吊耳,请再次刷吊耳", m_OpName);
}
}
//if (m_OpName == "J07ET030")
//{
// if (Convert.ToBoolean(S_plcBackGo))
// {
// SendMessageFun.SendInfomation("TestWorkErrorBox", "1", m_OpName);
// }
//}
break;
// PLC 程序号
case "125":
// 将程序号转发给前端页面
string returnValue = e.TagValue.ToString();
SendMessageFun.SendInfomation("CodeNumber", returnValue, m_OpName);
break;
// PLC 程序号的第几颗螺丝
case "126":
returnValue = e.TagValue.ToString();
SendMessageFun.SendInfomation("CodeNumberWorkNumber", returnValue, m_OpName);
break;
}
break;
}
}
}
//1.工件到位后PLC给MES传递机型(DBX0.4)(44)
//MES判断条码是否全部扫描完成
//PLC给出允许保存(DBX100.2)(19)MES见到(DBX100.2)(19)为1后给出保存完成(DBX102.2)(20)
//PLC见到保存完成(DBX102.2)(20)为1后清空允许保存(DBX100.2)(19)
//MES见到允许保存(DBX100.2)(19)为0后清空保存完成(DBX102.2)(20)
//MES判断总合格标志(INT104)(21)为1后给出合格放行(DBX2.5)(51)
/// <summary>
/// 扫描条码
/// </summary>
/// <param name="OpName"></param>
/// <param name="barcode"></param>
public void fun_Barcode(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(Barcode, e);
}
/// <summary>
/// 传递机型
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_EngineTypeGetOverPLC(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(EngineTypeGetOver_PLC, e);
}
/// <summary>
/// 合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_ConfirmOkGo(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(ConfirmOkGo, e);
}
/// <summary>
/// 不合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_FalseGo(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(FalseGO, e);
}
/// <summary>
/// 允许保存
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_MesRead(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(MesRead, e);
}
/// <summary>
/// 保存完成
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_MesReadOver(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(MesReadOver, e);
}
/// <summary>
/// 工件到位离开(清空所有的MES信号)
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_WorkStart(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(WorkStart, e);
}
/// <summary>
/// 处理WEB页面发送过来的请求m_Command + "|" + m_Value;
/// </summary>
/// <param name="OpName"></param>
/// <param name="Content"></param>
public void fun_WebSubmit(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(WebSubmit, e);
}
/// <summary>
/// 工位是否合格
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_IsOk(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(IsOk, e);
}
/// <summary>
/// 系统健康心跳监测
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_HeartBeatMIS(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(HeartBeat, e);
}
/// <summary>
/// MES实时保存质量数据
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
public void fun_MesSaveNowData(DoWhatPlc.CustomeEvetnArgs e)
{
ThreadPool.QueueUserWorkItem(MesSaveNowData, e);
}
}
}

View File

@@ -0,0 +1,214 @@
using System;
using System.Data;
using bizFacade;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 正常逻辑工作(传递机型)
/// </summary>
/// <param name="OpName"></param>
/// <param name="EngineTypeID"></param>
/// <param name="EngineType"></param>
/// <param name="EngineID"></param>
/// <param name="PartPallet_Code"></param>
private void EngineTypeGetOver_PLC_Work(string OpName, int EngineTypeID, string EngineType, string EngineID, int PartPallet_Code,string OrderForm)
{
int IsAllowWork;
int RepairPartStatusPLC = 0;
int MES_QualityMask = 1;
DataTable dt;
dt = BaseDataSystemMES.EngineTypeChange(OpName, EngineType);
//提示机型发生变化
if (dt.Rows.Count > 0)
{
string mesValue = Newtonsoft.Json.JsonConvert.SerializeObject(dt);//<DoWhatPlc.CustomeEvetnArgs>(recData);
string message = "MES|MaterialList_Dif_Resources|" + OpName + "|" + mesValue;
SendMessage.AsyncSendMessage(message);
}
if(OpName == "J07MA050")
{
// 搜索是否为换型工件,是的话进抽检模式
dt = BaseDataSystemMES.EngineTypeChange_MA050(EngineType);
//提示机型发生变化
if (Convert.ToInt32(dt.Rows[0]["result"]) == 1)
{
string message = "MES|MaterialList_Dif_Resources_MA050|" + OpName + "|" + 1;
SendMessage.AsyncSendMessage(message);
}
}
if(OpName == "J07MA040")
{
// 判断是否存在细一轴 若存在则去反给PLC11.235
DataTable OneAxleDt = BaseDataSystemMES.Get_EngineOneAxle(EngineType);
if (Convert.ToInt32(OneAxleDt.Rows[0]["result"]) == 1)
{
MIS_BASE.WritePLC(35, OpName, true);
SendMessageFun.AsyncSendMessage_Notice(OpName, "该工件存在细一轴物料,请注意!");
}
}
//电子看板_装配零件_临时表_增加_北汽
//第二步将零件信息转移到零件_临时表中
BaseDataSystemMES.MesServer_Process_EngineTypeOverBQ(OpName);
//通知web显示
SendMessageFun.SendMessage("1235", "1111", OpName);
//MIS_BASE.Read_PalletInfo(OpName, out MES_QualityMask);//合格标志 合格标志暂时改为即时响应式的
MIS_BASE.Read_RepairStatus_PLC(OpName, out RepairPartStatusPLC);//返修标志
//SendMessageFun.SendInfomation("QualityMask", Convert.ToString(MES_QualityMask), OpName);//显示合格标志
SendMessageFun.SendInfomation("RepairPartStatusPLC", Convert.ToString(RepairPartStatusPLC), OpName);//显示返修标志
if (MES_QualityMask == 2)
{
// 暂时先屏蔽掉
////工作完成
//MIS_BASE.Write_MaterialVerifyOver(OpName, true);
//SendMessageFun.SendInfomation("NgGO", "1", OpName);//显示不合格标志
//return;
}
//第三步,用于工件离开后完工数量统计及工件编号追溯
//BaseDataSystemMES.MaterialPush_EngineIDStatus_Insert(OpName);//更新订单产量
// 读取当前工件螺丝数量
DataTable dt3 = BaseDataSystemMES.Get_WorkPositionSizeByPBOM(OpName, EngineType);
// 变量类型代码数组
// 128 ~ 167
//遍历 将所需要写入地址的值读取出来写入到相应地址中
for (int i = 0; i <= dt3.Rows.Count - 1; i++)
{
// 读取当前行的数据 判断该放到第几行 将对于的数据放到对应数据区中
// 获取OP操作号 用于判断放哪个地址
int OPNumber = Convert.ToInt32(dt3.Rows[i]["OP本工位操作顺序号"]);
// 128 ~ 137 操作类型
MIS_BASE.WritePLC(127 + OPNumber, OpName, dt3.Rows[i]["主线设备操作类型"]);
// 138 ~ 147 拧紧程序号
MIS_BASE.WritePLC(137 + OPNumber, OpName, dt3.Rows[i]["拧紧程序号"]);
// 148 ~ 157 螺栓数量
MIS_BASE.WritePLC(147 + OPNumber, OpName, dt3.Rows[i]["传递数量"]);
// 158 ~ 167 OP操作号(操作顺序 预留) 目前不用写入这个而是根据这个判断数据放对应区第几行
}
//读取当前法兰类型发送给PLC(124)
if(OpName == "J07MA070")
{
DataTable dt4 = BaseDataSystemMES.Get_EngineFlangeType(EngineType);
int flange = Convert.ToInt32(dt4.Rows[0]["flange"]);
if (dt4.Rows.Count > 0) MIS_BASE.WritePLC(124, OpName, flange);
// 发送有无pkB 若有就发1
if (BaseDataSystemMES.Get_IsExistPKB(EngineType))
{
MIS_BASE.WritePLC(112, OpName, 1);
}
else
{
MIS_BASE.WritePLC(112, OpName, 0);
}
}
//判断当前工件是否为售后机型 0.7(53)
int Aftermarket;
if (OpName == "J07MA080")
{
DataTable dt4 = BaseDataSystemMES.Get_EngineAftermarketType(EngineType);
Aftermarket = Convert.ToInt32(dt4.Rows[0]["是否售后机型"]);
MIS_BASE.WritePLC(53, OpName, Aftermarket);
if(Aftermarket == 1)
{
string message = "MES|ShowTipBox|" + OpName + "|该工件为售后机型,需手动打印铭牌!";
SendMessage.AsyncSendMessage(message);
}
}
//读取当前脉冲轮类型发送给PLC(99)
if (OpName == "J07ET030")
{
DataTable dt5 = BaseDataSystemMES.Get_ImpulseWheelMeter(EngineType);
int impulseWheelMeter = Convert.ToInt32(dt5.Rows[0]["result"]);
if (dt5.Rows.Count > 0) MIS_BASE.WritePLC(99, OpName, impulseWheelMeter);
if (EngineType == "1384033006") MIS_BASE.WritePLC(53, OpName, true);
DataTable dt6 = BaseDataSystemMES.Get_EmptySwitch_ONOFF(EngineType);
MIS_BASE.WritePLC(114, OpName, dt6.Rows[0]["result"]);
DataTable dt7 = BaseDataSystemMES.Get_Test_FrockType(EngineType);
MIS_BASE.WritePLC(17, OpName, dt7.Rows[0]["result"]);
}
//第四步,获取是否允许工作
BaseDataSystemMES.MesServer_Judge_IsCanWork(OpName, out IsAllowWork);
//暂时先定义为扫描完成才能进行压装工作,因为考虑到工作完成后,操作工未必会去扫描物料的情况
if (IsAllowWork == 1)
{
//通知PLC允许工作,允许工作在保存完成时清空
MIS_BASE.Write_FixAllow(OpName, true);
}
else
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "请扫描物料!");
}
}
/// <summary>
/// 二次工作
/// </summary>
/// <param name="OpName"></param>
private void EngineTypeGetOver_PLC_Work_two(string OpName)
{
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
EngineTypeGetOver_PLC_Work(OpName, EngineTypeID, EngineType, EngineID, Convert.ToInt32(PartPallet_Code), OrderForm);
}
/// <summary>
/// 跳过二次工作
/// </summary>
/// <param name="OpName"></param>
private void EngineTypeGetOver_PLC_Work_Skip(string OpName)
{
//MIS_BASE.Write_MesReadOver(OpName, true);
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
/// <summary>
/// 返修件需要工作
/// </summary>
/// <param name="OpName">工位号</param>
private void IsNeedRepaire_OK(string OpName)
{
string orderForm = "";
int engineTypeID;
string engineType = "";
string engineID = "";
string palletCode = "";
int isRepair;
string repairCode = "";
//从监控系统中查询出本工位信息
BaseDataSystemMES.OpName_MIS_Moby_Select(OpName,
out orderForm, out engineTypeID, out engineType,
out engineID, out palletCode, out isRepair, out repairCode);
EngineTypeGetOver_PLC_Work(OpName, engineTypeID, engineType, engineID, Convert.ToInt32(palletCode),orderForm);
}
}
}

View File

@@ -0,0 +1,127 @@
using System;
using bizFacade;
//using SystemFramework;
namespace MesServerFunctions
{
/// <summary>
/// 此类用于向WEB发送各种类型消息
/// </summary>
partial class FunctionMES
{
/// <summary>
/// 批量发送WEB消息Value为BOOL值
/// </summary>
/// <param name="MessageNumm">消息编号组合</param>
/// <param name="Value">消息值组合</param>
/// <param name="OpName">工位号</param>
void Sendmessage(string MessageNumm,string Value, string OpName)
{
for (int i=0;i<MessageNumm.Length;i++)
{
Sendmessage(MessageNumm[i], Value[i].ToString(), OpName);
}
}
/// <summary>
/// 选择发送给WEB的消息
/// </summary>
/// <param name="Num">消息类型</param>
/// <param name="OpName">消息工位</param>
string Sendmessage(char Num,string Value, string OpName)
{
string SendMessage;
string result = "";
switch (Num)
{
case '1':
//1直接在界面通过选择机型确认工序内容
SendMessage = "MES|ProcessList|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '2':
//2显示物料
SendMessage = "MES|MaterialList|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '3':
//3显示操作指导图片
SendMessage = "MES|PicShow|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '4':
//4订单完工模块刷新完成数量
SendMessage = "MES|OrderFormList|" + OpName + "|" + Value;
AsyncSendMessage(SendMessage);
break;
case '5':
SendMessage = "MES|ShowMoby|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '6':
SendMessage = "MES|MaterialCheckPosition|" + OpName + "|" +Value;
result = AsyncSendMessage(SendMessage);
break;
case '7':
SendMessage = "MES|WorkStart|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case '8'://清除MES生成编号
break;
case '9':
SendMessage = "MES|ConfirmOkGo|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
case 'a':
SendMessage = "MES|FixAllow|" + OpName + "|" + Value;
result = AsyncSendMessage(SendMessage);
break;
}
return result;
}
/// <summary>
/// 向WEB发送信息value为字符串
/// </summary>
/// <param name="Command">消息种类</param>
/// <param name="Value">消息内容</param>
/// <param name="OpName">工位号</param>
string SendInfomation(string Command, string Value, string OpName)
{
string SendMessage = "MES|" + Command + "|" + OpName + "|" + Value;
return AsyncSendMessage(SendMessage);
}
/// <summary>
/// 发送在线产量、在线节拍
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void SendActuallyCount(string OpName, int tagValue)
{
//当工件离开时,更新在线产量、在线节拍
if (tagValue == 0)
{
try
{
int opNameCount = 0;//在线产量
int opNameCountTime = 0;//在线节拍
//基本数据_工作日历_班次产量查询_New
BaseDataSystemMES.OpNameCount_New(OpName, out opNameCount, out opNameCountTime);
string SendMessage;
SendMessage = "MES|ActuallyCount|" + OpName + "|" + opNameCount.ToString() + "&" + opNameCountTime.ToString();
AsyncSendMessage(SendMessage);
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:SendActuallyCount");
}
}
}
}
}

View File

@@ -0,0 +1,53 @@
using bizFacade;
//using SystemFramework;
using MesServerWork;
using DataLinkMesWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 发送信息到MES通讯服务器或者其他的
/// </summary>
/// <param name="Message"></param>
private string AsyncSendMessage(string Message)
{
return MIS_BASE.asyncSendMessage(Message);
}
/// <summary>
/// 发送提示消息
/// </summary>
/// <param name="Message"></param>
private void AsyncSendMessage_Notice(string opname, string notice)
{
//通知Web界面
BaseDataSystemMES.Web_Notice_Insert(opname, notice);
string SendMessage = "MES|Notice|" + opname + "|" + "1";
MIS_BASE.asyncSendMessage(SendMessage);
}
/// <summary>
/// 发送信息到打印机
/// </summary>
/// <param name="Message"></param>
private void asyncSendMessageToMark(string Message)
{
string messageSend = (string)Message;
//UDPClientSend.Send_ALL(ApplicationConfig.MES_MarkPortNum, messageSend);
}
/// <summary>
/// 发送信息到LED
/// </summary>
/// <param name="Message"></param>
private void asyncSendMessageLED(string OpName)
{
//发送到大屏幕显示 41104
string strMessage = "MIS|" + OpName + "|" + "0" + "|" + "1";
//UDPClientSend.Send_ALL(ApplicationConfig.Port_ShowLED_ProductCount, strMessage);
}
}
}

View File

@@ -0,0 +1,208 @@
using System;
using System.Data;
using System.Windows.Forms;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
///1.扫描配送单号用于接收物料扫描单号的时候将接收的物料信息显示在“物料拉动”Tab区域
///2.扫描料箱标签/看板卡,用于追溯物料批次信息
///3.扫描零件条码,根据零件图号进行防错
///第一步,判断条码类型,根据条码类型,执行对应的存储过程
///第二步,条码类型(将扫描的条码保存到对应的表中)
///第三步,扫描完成之后给出允许工作信号
/// 处理页面扫描条码
/// </summary>
/// <param name="OpName"></param>
/// <param name="barcode"></param>
public void Barcode(object e)
{
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
string barcode = Convert.ToString(msgEvent.TagValue);
SendMessageFun.SendInfomation("BarCodeData", barcode, OpName); // 将扫码值发送给前端
string AlarmStr = "";
bool isShowBarNGTipBox;
int IsAllowWork;
bool IsSuccess = false;
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
// 判断是否存在异常导致不允许工作 输出msg到前端
DataTable OpNameIsWorkDt = BaseDataSystemMES.OpNameIsAllowWork(OpName);
if (Convert.ToInt32(OpNameIsWorkDt.Rows[0]["提示类型"]) == 3)
{
SendMessageFun.SendInfomation("ShowTipBox", OpNameIsWorkDt.Rows[0]["提示文本"].ToString(), OpName);
return;
}
bool EngineGetOver_PLC_NextWorkStep;
//传递机型是否到位
MIS_BASE.Read_EngineGetOver_PLC(OpName, out EngineGetOver_PLC_NextWorkStep);
if (!EngineGetOver_PLC_NextWorkStep)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "PLC未传递机型");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描条码失败,请检查扫码位置是否正确!", OpName);
return;
}
// MA080 只扫描铭牌信息记录 记录完就退出
int SaveBarCodeStatusType = 0;
if (OpName == "J07MA080")
{
bool isMaterialVerifyOver;
MIS_BASE.Read_MaterialVerifyOver(OpName,out isMaterialVerifyOver);
if (isMaterialVerifyOver) {
SendMessageFun.AsyncSendMessage_Notice(OpName, "工作已完成,不再校验铭牌内容");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描条码失败,请检查扫码位置是否正确!", OpName);
return;
}
// 1.查看铭牌信息是否存在铭牌内容
// 2.校验铭牌信息 成功则保存标志位(168)
string barCodeData = MIS_BASE.ReadPLC(40, OpName).ToString();
if(barCodeData == null || barCodeData == "")
{
// 先校验有没有记录 如果没有则继续正常提示
DataTable barCodeCheckDt = BaseDataSystemMES.Check_MA080BarCode(EngineID,barcode);
if(barCodeCheckDt.Rows.Count > 0) {
MIS_BASE.WritePLC(168, OpName, 4);
SaveBarCodeStatusType = 2;
SendMessageFun.AsyncSendMessage_Notice(OpName, "存在打印铭牌记录,校验成功!");
}
else
{
MIS_BASE.WritePLC(168, OpName, 1);
SaveBarCodeStatusType = 1;
SendMessageFun.AsyncSendMessage_Notice(OpName, "请先打印铭牌后进行校验信息");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描条码失败,请检查扫码位置是否正确!", OpName);
}
}
else
{
if(barCodeData == barcode)
{
// 校验条码中是否包含序列号
if (barcode.Contains(EngineID.Split('*')[2]))
{
MIS_BASE.WritePLC(168, OpName, 2);
SaveBarCodeStatusType = 2;
SendMessageFun.AsyncSendMessage_Notice(OpName, "铭牌二维码信息校验成功");
BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 2);
}
else
{
MIS_BASE.WritePLC(168, OpName, 3);
SaveBarCodeStatusType = 3;
SendMessageFun.AsyncSendMessage_Notice(OpName, "所扫铭牌二维码中未包含条码序列号,请确认条码是否打印正确!");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫铭牌二维码失败,请检查扫码位置是否正确!", OpName);
}
}
else
{
MIS_BASE.WritePLC(168, OpName, 3);
SaveBarCodeStatusType = 3;
SendMessageFun.AsyncSendMessage_Notice(OpName, "扫码信息于打印信息不一致!校验失败");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描铭牌二维码失败,请检查扫码位置是否正确!", OpName);
}
SendMessageFun.SendInfomation("J07MA080BarCodeCheckBrushWriting", barcode, OpName);
if(SaveBarCodeStatusType == 2)
{
bool isOk = BaseDataSystemMES.BarCodeCheck_Add(OpName, EngineID, EngineType, EngineTypeID, barcode, SaveBarCodeStatusType);
if (isOk)
{
// 通知前端刷新结果
SendMessageFun.SendInfomation("J07MA080BarCodeCheckBrushWriting", barcode, OpName);
}
else
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "铭牌二维码信息保存失败");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描铭牌二维码失败,请检查扫码位置是否正确!", OpName);
}
}
}
return;
}
//物料验证
BaseDataSystemMES.PartMaterial_DM_Update(OpName, barcode, out IsSuccess);
if (!IsSuccess)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "条码无效,请确认");
isShowBarNGTipBox = BaseDataSystemMES.Check_BarCodeNGTemp(OpName, 1);
if (isShowBarNGTipBox) SendMessageFun.SendInfomation("ShowTipBox", "多次扫描物料码失败,请检查扫码位置是否正确!", OpName);
return;
}
else
{
SendMessageFun.SendInfomation("MaterialList", "1", OpName);//通知界面更新零件信息
}
//获取是否允许工作
BaseDataSystemMES.MesServer_Judge_IsCanWork(OpName, out IsAllowWork);
//此处逻辑有问题 需要考虑到批次扫描 提示PLC未传递机型的情况
if (IsAllowWork == 1)
{
//BaseDataSystemMES.Material_Insert(OpName, 1);
//更新订单完工数量及物料
SendMessageFun.SendMessage("24", "11", OpName);
//通知PLC允许工作,允许工作在保存完成时清空
MIS_BASE.Write_FixAllow(OpName, true);
// 在物料验证完成后110 工位将该条码的总分先关系保存 并且信息拉取过来并且给允许工作 将两个工位该总成绑定的物料都给拉过来
if(OpName == "J07MA110")
{
BaseDataSystemMES.BusPartLine_Add(EngineID, barcode, OpName, OrderForm, EngineType);
BaseDataSystemMES.Update_DataBaind(EngineID,OpName,"J07PA050");
BaseDataSystemMES.Update_DataBaind(EngineID,OpName,"J07PA060");
}
}
else
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "请扫描物料!");
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(4, e, "Fun1052", err);
////ApplicationLog.WriteLog(err, "Function02:Barcode");
}
}
}
}
}

View File

@@ -0,0 +1,41 @@
using System;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void ConfirmOkGo(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
BaseDataSystemMES.Material_Insert(OpName, 1);
//更新订单完工数量及物料
Sendmessage("24", "11", OpName);
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:ConfirmOkGo");
}
}
}
}

View File

@@ -0,0 +1,129 @@
using System;
using System.CodeDom;
using System.Data;
using System.Windows.Forms;
using System.Xml.Linq;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// PLC传递机型处理
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void EngineTypeGetOver_PLC(object e)
{
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
// 判断是否存在异常导致不允许工作 输出msg到前端
DataTable OpNameIsWorkDt = BaseDataSystemMES.OpNameIsAllowWork(OpName);
if(OpNameIsWorkDt.Rows.Count > 0)
{
if (Convert.ToInt32(OpNameIsWorkDt.Rows[0]["提示类型"]) == 3)
{
SendMessageFun.SendInfomation("ShowTipBox", OpNameIsWorkDt.Rows[0]["提示文本"].ToString(), OpName);
return;
}
}
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
if (EngineTypeID <= 0 || EngineID.Length == 0 || EngineType.Length == 0 || OrderForm.Length == 0)
{
SendMessageFun.AsyncSendMessage_Notice(OpName, "PLC传递机型为空");
return;
}
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineTypeID, EngineTypeID.ToString());
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineType, EngineType);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID, EngineID);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.OrderForm, OrderForm);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.PartPallet_Code, PartPallet_Code.ToString());
// 判断是否返修件 是否需要继续工作
int isBackWork = 0;
DataTable backWorkDt = BaseDataSystemMES.Get_IsBackWork(OpName, EngineID);
if (backWorkDt.Rows[0]["result"].ToString() == "1")
{
// 写返修点并且退出方法
MIS_BASE.WritePLC(33, OpName, true);
string message = "MES|ShowTipBox|" + OpName + "|该工件为返工工件!";
SendMessage.AsyncSendMessage(message);
if(OpName != "J07ET040")
{
return;
}
else
{
// 设置一个标识点表示这个是ET040 返修件
isBackWork = 1;
}
}
if(OpName == "J07ET060")
{
DataTable ET060BackWorkDt = BaseDataSystemMES.Get_IsET060BackWork(EngineID);
if (backWorkDt.Rows[0]["result"].ToString() == "1")
{
// 写返修点并且退出方法
MIS_BASE.WritePLC(33, OpName, true);
string message = "MES|ShowTipBox|" + OpName + "|该工件为返工工件!";
SendMessage.AsyncSendMessage(message);
}
}
//显示当前订单信息
//SendMessage.ShowMoby(OpName);
// ET030 无屏幕 不判断是否重复工作过
//判断该订单数据是否已经工作过有的话则在WEB跳出弹窗选择 并同时禁止工作
DataTable dt2 = BaseDataSystemMES.EngineIsTwoWork(OpName, OrderForm, EngineID);
if (dt2.Rows[0]["result"].ToString() == "1" && isBackWork == 0) //已完成
{
//不允许工作
MIS_BASE.Write_FixAllow(OpName, false);
//通知WEB校验重新工作还是跳过 点重新工作给允许工作,点跳过给工作完成
string message = "MES|Engine_Is_TwoWork|" + OpName + "|1";
SendMessage.AsyncSendMessage(message);
}
else
{
//正常传递机型流程
EngineTypeGetOver_PLC_Work(OpName, EngineTypeID, EngineType, EngineID, PartPallet_Code, OrderForm);
}
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(2, e, "Fun1052", err);
////ApplicationLog.WriteLog(err, "Function02:EngineTypeGetOver_PLC");
}
}
}
}
}

View File

@@ -0,0 +1,46 @@
using System;
using System.Data;
using System.Windows.Forms;
using System.Xml.Linq;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 不合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void FalseGO(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
//不合格放行信号
//MIS_BASE.Write_FalseGO(OpName, true);
//总合格标志2不合格
BaseDataSystemMES.Material_Insert_NG(OpName, 2);
Sendmessage("24", "11", OpName);
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,54 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// MES与PLC心跳监听
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void HeartBeat(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
//返写在MES心跳中
//MIS_BASE.WritePLC(15, OpName, tagValue);
if (OpName == "J07MA010")
{
// 给MA010工位推送实时温度
SendMessageFun.SendInfomation("MA010Temperature", MIS_BASE.ReadPLC(110, OpName).ToString(), OpName);
// 读取MA010MES写入温度发送到码块
DataTable dt;
BaseDataSystemMES.Get_TempData(OpName, "温度", out dt);
MIS_BASE.WritePLC(111, OpName, dt.Rows[0]["数值"]);
}
// 获取登录状态
if (tagValue == 1)
{
//DataTable tempDt;
//BaseDataSystemMES.Get_TempData(OpName, "登陆状态", out tempDt);
//if (tempDt.Rows.Count > 0) MIS_BASE.WritePLC(54, OpName, tempDt.Rows[0]["数值"]);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,102 @@
using bizFacade;
using Function1052.SaveCode;
using MesServerWork;
using MesWork;
using System;
using System.Data;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 允许保存(针对半自动和手动压装工位)
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void MesRead(object e)
{
{
try
{
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm);
if (tagValue == 1)
{
int qualityMask;
//先去判断是否需要弹出弹窗若弹出点确认后给PLC发一个点表示点过了
DataTable WordOver = BaseDataSystemMES.WorkOver_IsShowWindow(OpName, EngineTypeID);
if (Convert.ToInt32(WordOver.Rows[0]["result"]) == 1)
{
string message = "MES|WorkOver_Is_ShowWindow|" + OpName + "|" + WordOver.Rows[0]["msg"];
SendMessage.AsyncSendMessage(message);
//MIS_BASE.WritePLC(35, OpName, 1);
}
// MA080 需要保存铭牌二维码信息
if (OpName == "J07MA080")
{
SaveCode_J07MA080.SaveCode(OpName);
}
// 保存质量数据
qualityMask = MisDataSaveDateMesRead.Funtion.MesRead(OpName, tagValue.ToString(), msgEvent.TagID.ToString());
// 保存物料数据
BaseDataSystemMES.Material_Insert(OpName, qualityMask);
// 测量数据发动机在线状态
BaseDataSystemMES.WorkStartInsert(OpName, qualityMask);
// 推送质量数据到MES的页面
SendMessageFun.SendInfomation("ShowTimelyQuality", "1&" + qualityMask.ToString(), OpName);
// ET030 需要保存试验台信息
if (OpName == "J07ET030")
{
BaseDataSystemMES.TestStandDataSave();
// 判断如果合格标志是不合格那就添加到返工记录里去 }
if(qualityMask == 2)
{
BaseDataSystemMES.TestStandBackWorkData(EngineID, EngineType, OrderForm);
}
}
//对应手动工位的
//MIS_BASE.Write_ConfirmOkGo(OpName, true);
//通知设备MES的质量数据和物料数据保存完成
MIS_BASE.Write_MesReadOver(OpName, true);
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
//统计在线产量,在线节拍
SendMessage.SendActuallyCount(OpName, tagValue);
}
else
{
MIS_BASE.Write_MesReadOver(OpName, false);
}
}
}
catch (Exception err)
{
// 保存出错日志 1.申请上线 2.传递机型 3.允许保存 4.扫码
MisDataSaveDate.FuntionMesRead.Alarm_SaveFileLog4Error(3, e, "Fun1052", err);
////ApplicationLog.WriteLog(err, "Function08:MesReadOver");
}
}
}
}
}

View File

@@ -0,0 +1,55 @@
using System;
//using SystemFramework;
using MesServerWork;
using bizFacade;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 保存完成(针对半自动和手动压装工位)
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void MesReadOver(object e)
{
//try
//{
// DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
// string OpName = Convert.ToString(msgEvent.OpName);
// var tagValue = msgEvent.TagValue.ToString ();
// if (tagValue == "1" | tagValue.ToLower () == "true")
// {
// int qualityMask;
// MIS_BASE.Read_QualityMask(OpName, out qualityMask);
// SendInfomation("ShowTimelyQuality", "1&" + qualityMask.ToString(), OpName);//发给Web页面显示质量数据
// if (qualityMask == 1)//全部OK给出合格放行
// {
// //如果存在线外扫描工位,根据扫描条码绑定线外数据 需要时解除禁用
// //BaseDataSystemMES.TransLaunchDataByMainMaterial(OpName, EngineType, EngineID, EngineTypeID);
// //如果存在线外排队工位,根据排队编号绑定线外数据 需要时解除禁用
// ////BaseDataSystemMES.MailLineAndSubLineData_InsertByEngineID_Subline(OpName,EngineID, EngineTypeID, EngineType);
// MIS_BASE.Write_ConfirmOkGo(OpName, true);
// //MIS_BASE.Write_FalseGO(OpName, false);
// }
// else
// {
// //MIS_BASE.Write_ConfirmOkGo(OpName, false);
// MIS_BASE.Write_FalseGO(OpName, true);
// }
// }
//}
//catch (Exception err)
//{
// ////ApplicationLog.WriteLog(err, "Function02:MesReadOver");
//}
}
}
}

View File

@@ -0,0 +1,40 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Data;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using static System.Net.Mime.MediaTypeNames;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// MES保存实时质量数据
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void MesSaveNowData(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
// 直接发送实时的 质量数据
string message = MisDataSaveDateMesRead.Funtion.GetRealTimeQualityData(OpName);
//推送质量数据到MES的页面
SendMessage.AsyncSendMessage("MES|ShowTimelyQuality_Resources|" + OpName + "|" + message);
//SendMessageFun.SendMessageMESToWEB("ShowTimelyQuality", "1&" + qualityMask.ToString(), OpName);
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,429 @@
using System;
using MesServerWork;
using bizFacade;
using System.Threading;
using MisDataSaveDate;
using System.Collections;
using System.Data;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 处理WEB页面发送过来的请求m_Command + "|" + m_Value;
/// </summary>
/// <param name="OpName"></param>
/// <param name="Content"></param>
private void WebSubmit(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName=Convert.ToString(msgEvent.OpName);
string Content = Convert.ToString(msgEvent.TagValue);
string[] dataArray = Content.Split('|');
if (dataArray.Length != 2)
return;
//消息类型
string m_Command = dataArray[0].ToString();
//消息参数
string m_Value = dataArray[1].ToString();
//消息参数数量
string[] m_Value_array = m_Value.Split('&');
//消息参数长度
int m_Value_length = m_Value_array.Length;
//工件信息
string engineID = "";
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
{
return;
}
if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName))
{
engineID = MIS_BASE.hashtable_EngineGetOver_EngineID[OpName].ToString();
}
DoWhatPlc.CustomeEvetnArgs _e = new DoWhatPlc.CustomeEvetnArgs();
_e.OpName = OpName;
_e.TagValue = m_Value;
string strValue;
int intValue;
//根据请求的命令处理逻辑
switch (m_Command)
{
case "Barcode":
if (m_Value_length > 1) return;
fun_Barcode(_e);
break;
case "ConfirmOkGo"://合格放行
//删除不合格放行记录
//修改托盘状态
//Update_PalletStatus(OpName, 1, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_ConfirmOkGo(OpName, true);
MIS_BASE.Write_FalseGO(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
break;
case "FalseGO"://返修放行
//修改托盘状态
//Update_PalletStatus(OpName, 3, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "NgGO"://不合格放行
//修改托盘状态
//Update_PalletStatus(OpName, 2, false);
//保存不合格信息(必须保存不合格放行信息由于B5A的Moby没有不合格标志位)
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Insert(OpName, engineID, "", "");
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "OnLineState"://在线0、离线1、屏蔽2
try
{
if (m_Value_length > 1) return;
int a = Convert.ToInt32(m_Value);
if (a <= 2)
{
BaseDataSystemMES.IsOnLine_Update(OpName, m_Value.ToString());
MIS_BASE.Write_OnLineState(OpName, Convert.ToInt32(m_Value));
if (a == 2) SendMessage.AsyncSendMessage_Notice(OpName, "屏蔽MES");
if (a == 0) SendMessage.AsyncSendMessage_Notice(OpName, "启用MES");
}
}
catch
{
}
break;
case "Reset"://复位将MES所有的信息都复位了
SetMoby(OpName);//将MES所有信号清空
break;
case "FixAllow"://重新拧紧
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_FixAllow(OpName, true);
break;
case "IsAutoGetEngineID"://自动手动申请编号(线首)
if (m_Value_length > 1) return;
MIS_BASE.Write_IsAutoGetEngineID(OpName, Convert.ToInt32(m_Value));
break;
case "PartPalletGoOver"://空托盘放行
int Is_PartPalletGoOver;
MIS_BASE.Read_PartPalletGoOver(OpName, out Is_PartPalletGoOver);
if (Is_PartPalletGoOver == 1)
{
MIS_BASE.Write_PartPalletGoOver(OpName, 1);
}
else
{
MIS_BASE.Write_PartPalletGoOver(OpName,0);
}
break;
case "SetMoby"://清空托盘(线首)
SetMoby(OpName);//将MES所有信号清空
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "RepairUplineMES"://返修上线
MIS_BASE.Write_RepairUpline_MES(OpName, true);
break;
case "CancelRepair"://将返修件置为正常件
break;
case "PartPalletCode"://申请写入托盘号
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "WritePartPalletCode"://写入托盘号
if (m_Value_length > 1) return;
MIS_BASE.Write_PalletCode(OpName, Convert.ToInt32(m_Value));
break;
case "Normal"://启用正常拧紧工位
MIS_BASE.Write_Normal(OpName, 1);
MIS_BASE.Write_UnNormal(OpName, 0);
break;
case "UnNormal"://启用备用拧紧工位
MIS_BASE.Write_Normal(OpName, 0);
MIS_BASE.Write_UnNormal(OpName, 1);
break;
case "ResetDevice"://复位设备
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
break;
case "IsNeedRepaire"://返修上线(返修上线点)
if (Convert.ToInt32(m_Value) == 1)
{
//修改托盘状态
MIS_BASE.Write_PalletInfo(OpName, 3);
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
IsNeedRepaire_OK(OpName);
}
else if (Convert.ToInt32(m_Value) == 0)
{
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
//直接给出工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
else
{ }
break;
case "ContinueMatch":
BaseDataSystemMES.QualityVerifyStatus_Hash_Write(OpName, true);
break;
//初始化网页信号
case "IniSingalToWeb":
InitializeSingalToWeb(OpName);
break;
case "Reset_Engine"://返修上线(返修上线点)
SetMoby(OpName);//将MES所有信号清空
//fun_EngineTypeGetOverPLC(OpName, 0);
//fun_EngineTypeGetOverPLC(OpName, 1);
break;
case "twoWorkSkip"://重新工作工件跳过工作(重新工作工件)
//工作完成
EngineTypeGetOver_PLC_Work_Skip(OpName);
break;
case "twoWork"://重新工作工件重新工作(重新工作工件)
//允许工作
EngineTypeGetOver_PLC_Work_two(OpName);
break;
case "WorkOver_Is_ShowWindow"://重新走保存逻辑
if (OpName == "J07MA140")
{
MIS_BASE.WritePLC(35, OpName, 1);
}
break;
case "FaultBackWork"://返修工件
// 写入地址
MIS_BASE.WritePLC(34, OpName, true);
break;
case "FaultBackWorkUnpack"://返修 拆解返工
// 写入地址
MIS_BASE.WritePLC(24, OpName, 1);
break;
case "FaultBackWorkSelect"://返修 选择工位返工
// 写入地址
MIS_BASE.WritePLC(24, OpName, 2);
break;
case "remedyWork"://补拧工件
// 接受传来的补拧程序号 补拧数量 拆分
string[] arr = m_Value.ToString().Split('&');
string codeNumber = arr[0];
string workCount = arr[1];
// 写入地址 在工件离开后清空
MIS_BASE.WritePLC(77, OpName, codeNumber);
MIS_BASE.WritePLC(88, OpName, workCount);
// 若这个点被置0了说明PLC那补拧结束了
MIS_BASE.WritePLC(30, OpName, true);
break;
case "remedyWorkEnd"://补拧工件
MIS_BASE.WritePLC(77, OpName, 0);
MIS_BASE.WritePLC(88, OpName, 0);
MIS_BASE.WritePLC(30, OpName, false);
break;
case "boltSpotCheck"://螺栓抽检
// 接受传来的补拧程序号 补拧数量 拆分
arr = m_Value.ToString().Split('&');
codeNumber = arr[0];
workCount = arr[1];
// 写入地址 在工件离开后清空
MIS_BASE.WritePLC(77, OpName, codeNumber);
MIS_BASE.WritePLC(88, OpName, workCount);
// 若这个点被置0了说明PLC那抽检结束了
MIS_BASE.WritePLC(31, OpName, true);
break;
case "boltSpotCheckEnd"://螺栓抽检结束
MIS_BASE.WritePLC(77, OpName, 0);
MIS_BASE.WritePLC(88, OpName, 0);
MIS_BASE.WritePLC(31, OpName, false);
break;
case "againGetNowData":
strValue = MIS_BASE.ReadPLC(40, OpName).ToString();
//通知前端显示铭牌信息
if (OpName == "J07MA080")
{
SendMessageFun.SendInfomation("WatchMA080barCode", strValue, OpName);
}
break;
case "againGetWorkPosition"://前端请求再次获取拧紧数据
// 接收到请求后读取这两个点的数据发给前台
// 查询螺丝号是否存在 存在则发送给前端
string CodeNumber;
MIS_BASE.Read_TagTypeID(125, OpName, out CodeNumber);
SendMessageFun.SendInfomation("CodeNumber", CodeNumber, OpName);
// 查询螺丝号下拧紧排序是否存在 存在则发送给前端
string CodeNumberWorkNumber;
MIS_BASE.Read_TagTypeID(126, OpName, out CodeNumberWorkNumber);
SendMessageFun.SendInfomation("CodeNumberWorkNumber", CodeNumberWorkNumber, OpName);
break;
case "closeWebWindow":// 前端窗口关闭
// 将持久化存储表中工位的登陆状态设置为接受值
BaseDataSystemMES.Set_TempData(OpName, "登陆状态", m_Value);
MIS_BASE.WritePLC(54, OpName, false);
break;
case "SkipDiskBearing":// 跳过盘轴
MIS_BASE.WritePLC(32, OpName, true);
Thread.Sleep(1000);
MIS_BASE.WritePLC(32, OpName, false);
break;
case "QuitEngineTypeCheck":// 发送给服务器换型请求,等待服务器换型判断发送到页面端
DataTable dt;
dt = BaseDataSystemMES.EngineTypeChange(OpName, m_Value);
//提示机型发生变化
if (dt.Rows.Count > 0)
{
string mesValue = Newtonsoft.Json.JsonConvert.SerializeObject(dt);//<DoWhatPlc.CustomeEvetnArgs>(recData);
string message = "MES|MaterialList_Dif_Resources|" + OpName + "|" + mesValue;
SendMessage.AsyncSendMessage(message);
// 写入MOBY 写入机型信息与清空总成号
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineType, mesValue);
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.EngineID, "");
//通知web显示
SendMessageFun.SendMessage("5", "1", OpName);
}
break;
default: break;
}
}
catch(Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:WebSubmit");
}
}
private void SetMoby(string OpName)
{
try
{
//清空Moby时需要将MES信号清空
MIS_BASE.Write_ClearMesMoby(OpName);
BaseDataSystemMES.MesServer_Process_EngineTypeOver(OpName);
Sendmessage("5123", "1111", OpName);
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
}
catch
{
}
}
/// 网页重现登录,恢复关闭前的页面状态
/// </summary>
/// <param name="Opname">工位号</param>
private void InitializeSingalToWeb(string Opname)
{
//工件到位 DBX0.1
bool S_WorkStart;
bool S_FixAllow;
bool S_EngineGetOver;
bool S_MaterialVerifyOver;
MIS_BASE.Read_WorkStart(Opname, out S_WorkStart);
MIS_BASE.Read_FixAllow(Opname, out S_FixAllow);
MIS_BASE.Read_EngineGetOver_PLC(Opname, out S_EngineGetOver);
MIS_BASE.Read_MaterialVerifyOver(Opname, out S_MaterialVerifyOver);
DataTable tempDt;
BaseDataSystemMES.Get_TempData(Opname, "登陆状态", out tempDt);
if (tempDt.Rows.Count > 0) MIS_BASE.WritePLC(54, Opname, tempDt.Rows[0]["数值"]);
Sendmessage("135", "1111", Opname);
string S_plcStatus;//DBX501.5 PLC直通1 强制放行 0 正常循环
// 新增查询PLC直通状态 网页显示
MIS_BASE.Read_TagTypeID(63, Opname, out S_plcStatus);
if (Convert.ToInt32(S_plcStatus) == 0)
{
SendMessageFun.SendInfomation("PlcStatus", "0", Opname);
}
else
{
SendMessageFun.SendInfomation("PlcStatus", "1", Opname);
}
string strValue = MIS_BASE.ReadPLC(40, Opname).ToString();
//通知前端显示铭牌信息
if (Opname == "J07MA080")
{
SendMessageFun.SendInfomation("WatchMA080barCode", strValue, Opname);
}
// 查询螺丝号是否存在 存在则发送给前端
string CodeNumber;
MIS_BASE.Read_TagTypeID(125, Opname, out CodeNumber);
if (CodeNumber != "0")
{
SendMessageFun.SendInfomation("CodeNumber", CodeNumber,Opname);
}
// 查询螺丝号下拧紧排序是否存在 存在则发送给前端
string CodeNumberWorkNumber;
MIS_BASE.Read_TagTypeID(126, Opname, out CodeNumberWorkNumber);
if (CodeNumberWorkNumber != "0")
{
SendMessageFun.SendInfomation("CodeNumberWorkNumber", CodeNumberWorkNumber,Opname);
}
if (S_WorkStart == true)
{
SendInfomation("WorkStart", Convert.ToString(Convert.ToInt32(S_WorkStart)), Opname);
}
if (S_FixAllow == true)
{
SendInfomation("FixAllow", Convert.ToString(Convert.ToInt32(S_FixAllow)), Opname);
}
if (S_MaterialVerifyOver == true)
{
SendInfomation("MaterialVerifyOver", Convert.ToString(Convert.ToInt32(S_MaterialVerifyOver)), Opname);
}
if (S_EngineGetOver == true)
{
SendInfomation("EngineTypeGetOverPLC", Convert.ToString(Convert.ToInt32(S_EngineGetOver)), Opname);
Sendmessage("2", "1111", Opname);
//SendMessage.ShowMoby(Opname);
// 直接发送实时的 质量数据
string message = MisDataSaveDateMesRead.Funtion.GetRealTimeQualityData(Opname);
//推送质量数据到MES的页面
SendMessage.AsyncSendMessage("MES|ShowTimelyQuality_Resources|" + Opname + "|" + message);
}
InitAlarm(Opname);
}
private void InitAlarm(string Opname)
{
FuntionMesRead.Alarm_InitAlarm_Send(Opname, out Hashtable ht);
foreach (DictionaryEntry kv in ht)
{
var TagID = kv.Key.ToString();
var TagValue = kv.Value.ToString();
FuntionMesRead.Send_AlarmMsg(TagID, TagValue);
}
}
}
}

View File

@@ -0,0 +1,45 @@
using bizFacade;
using MesServerWork;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 工位合格标志
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void IsOk(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
int qualityMask;
MIS_BASE.Read_QualityMask(OpName, out qualityMask);
//判断是否合格
if (qualityMask == 1)
{
qualityMask = 1;
} else {
qualityMask = 0;
}
//通知WEB修改状态
string message = "MES|QualityMask|" + OpName + "|" + qualityMask.ToString();
SendMessage.AsyncSendMessage(message);
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:FalseGO");
}
}
}
}

View File

@@ -0,0 +1,81 @@
using bizFacade;
using MesServerWork;
using System;
using System.Threading;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 工件到位与离开时清空MES自身信号
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void WorkStart(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue > 0)
{
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStartIn, DateTime.Now.ToString());
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStart, tagValue.ToString());
}
else
{
BaseDataSystemMES.OpName_MIS_MOBY_Insert(OpName, MobyTagType.WorkStartOut, DateTime.Now.ToString());
Thread.Sleep(500);
MIS_BASE.Write_MesReadOver(OpName, false);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
MIS_BASE.Write_EngineTypeGetOver_MES(OpName, false);
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, false);
//补拧工件 写入地址 在工件离开后清空
MIS_BASE.WritePLC(77, OpName, 0);
MIS_BASE.WritePLC(88, OpName, 0);
// 是否返修点
MIS_BASE.WritePLC(33, OpName, false);
MIS_BASE.WritePLC(34, OpName, false);
MIS_BASE.WritePLC(35, OpName, false);
if (OpName == "J07MA070")
{
MIS_BASE.WritePLC(124, OpName, 0);
MIS_BASE.WritePLC(112, OpName, 0);
}
// 清除程序号那些BYTE点
for (int i = 1;i <= 40; i++)
{
MIS_BASE.WritePLC(127+i, OpName, 0);
}
if(OpName == "J07MA080")
{
MIS_BASE.WritePLC(168, OpName, 0);
MIS_BASE.WritePLC(53, OpName, 0);
}
if (OpName == "J07ET030")
{
MIS_BASE.WritePLC(99, OpName, 0);
MIS_BASE.WritePLC(53, OpName, false);
MIS_BASE.WritePLC(114, OpName, 0);
}
if(OpName == "J07MA140")
{
MIS_BASE.WritePLC(35, OpName, 0);
}
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:WorkStart");
}
}
}
}

View File

@@ -0,0 +1,36 @@
using System.Reflection;
using System.Runtime.CompilerServices;
using System.Runtime.InteropServices;
// 有关程序集的常规信息通过以下
// 特性集控制。更改这些特性值可修改
// 与程序集关联的信息。
[assembly: AssemblyTitle("Function02")]
[assembly: AssemblyDescription("")]
[assembly: AssemblyConfiguration("")]
[assembly: AssemblyCompany("苏州宏软信息技术有限公司")]
[assembly: AssemblyProduct("Function02")]
[assembly: AssemblyCopyright("Copyright © 苏州宏软信息技术有限公司 2017")]
[assembly: AssemblyTrademark("")]
[assembly: AssemblyCulture("")]
// 将 ComVisible 设置为 false 使此程序集中的类型
// 对 COM 组件不可见。如果需要从 COM 访问此程序集中的类型,
// 则将该类型上的 ComVisible 特性设置为 true。
[assembly: ComVisible(false)]
// 如果此项目向 COM 公开,则下列 GUID 用于类型库的 ID
[assembly: Guid("47710f2c-e141-4252-8d13-701bf4c1c027")]
// 程序集的版本信息由下面四个值组成:
//
// 主版本
// 次版本
// 内部版本号
// 修订号
//
// 可以指定所有这些值,也可以使用“内部版本号”和“修订号”的默认值,
// 方法是按如下所示使用“*”:
// [assembly: AssemblyVersion("1.0.*")]
[assembly: AssemblyVersion("1.0.0.0")]
[assembly: AssemblyFileVersion("1.0.0.0")]

View File

@@ -0,0 +1,45 @@
using bizFacade;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Function1052.SaveCode
{
public class SaveCode_J07MA080
{
public static Boolean SaveCode(String OpName)
{
bool result = false;
try
{
//北汽福田_TCU_增加
//铭牌号 物料码
String nameplate;
//总成码
String EngineID;
//机型代码
String EngineTypeID;
//获取物料码
nameplate = DtWebApi.ReadWritePLC.ReadPLC("40", OpName).ToString();
//变速器总成码
EngineID = DtWebApi.ReadWritePLC.ReadPLC("10", OpName).ToString();
EngineTypeID = DtWebApi.ReadWritePLC.ReadPLC("11", OpName).ToString();
BaseDataSystemMES.TCU_Add(OpName, nameplate, EngineID, EngineTypeID);
result = true;
}
catch (Exception err)
{
}
return result;
}
}
}

View File

@@ -0,0 +1,19 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<runtime>
<assemblyBinding xmlns="urn:schemas-microsoft-com:asm.v1">
<dependentAssembly>
<assemblyIdentity name="Newtonsoft.Json" publicKeyToken="30ad4fe6b2a6aeed" culture="neutral"/>
<bindingRedirect oldVersion="0.0.0.0-13.0.0.0" newVersion="13.0.0.0"/>
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="System.Net.Http" publicKeyToken="b03f5f7f11d50a3a" culture="neutral"/>
<bindingRedirect oldVersion="0.0.0.0-4.2.0.0" newVersion="4.2.0.0"/>
</dependentAssembly>
<dependentAssembly>
<assemblyIdentity name="MQTTnet" publicKeyToken="b69712f52770c0a7" culture="neutral"/>
<bindingRedirect oldVersion="0.0.0.0-3.0.13.0" newVersion="3.0.13.0"/>
</dependentAssembly>
</assemblyBinding>
</runtime>
<startup><supportedRuntime version="v4.0" sku=".NETFramework,Version=v4.8"/></startup></configuration>

View File

@@ -0,0 +1,5 @@
SCC = This is a Source Code Control file
[Function02.csproj]
SCC_Aux_Path = "\\192.168.0.100\vss\MES4.0"
SCC_Project_Name = "$/MisData/MisData/MisData/MesServer.Function/Function02", ILHAAAAA

View File

@@ -0,0 +1,15 @@
<?xml version="1.0" encoding="utf-8"?>
<packages>
<package id="Microsoft.NETCore.Platforms" version="1.1.0" targetFramework="net461" />
<package id="MQTTnet" version="3.0.13" targetFramework="net461" />
<package id="MQTTnet.Extensions.ManagedClient" version="3.0.13" targetFramework="net461" />
<package id="NETStandard.Library" version="2.0.0" targetFramework="net461" />
<package id="Newtonsoft.Json" version="13.0.1" targetFramework="net461" />
<package id="System.Net.Security" version="4.3.2" targetFramework="net461" />
<package id="System.Net.WebSockets" version="4.3.0" targetFramework="net461" />
<package id="System.Net.WebSockets.Client" version="4.3.2" targetFramework="net461" />
<package id="System.Security.Cryptography.Algorithms" version="4.3.0" targetFramework="net461" requireReinstallation="true" />
<package id="System.Security.Cryptography.Encoding" version="4.3.0" targetFramework="net461" />
<package id="System.Security.Cryptography.Primitives" version="4.3.0" targetFramework="net461" />
<package id="System.Security.Cryptography.X509Certificates" version="4.3.0" targetFramework="net461" />
</packages>