using System;
using MesServerWork;
using bizFacade;
using System.Threading;
using MisDataSaveDate;
using System.Collections;
//using SystemFramework;
namespace MesServerFunctions
{
partial class FunctionMES
{
/// <summary>
/// 处理WEB页面发送过来的请求m_Command + "|" + m_Value;
/// </summary>
/// <param name="OpName"></param>
/// <param name="Content"></param>
private void WebSubmit(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName=Convert.ToString(msgEvent.OpName);
string Content = Convert.ToString(msgEvent.TagValue);
string[] dataArray = Content.Split('|');
if (dataArray.Length != 2)
return;
//消息类型
string m_Command = dataArray[0].ToString();
//消息参数
string m_Value = dataArray[1].ToString();
//消息参数数量
string[] m_Value_array = m_Value.Split('&');
//消息参数长度
int m_Value_length = m_Value_array.Length;
//工件信息
string engineID = "";
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName))
{
engineID = MIS_BASE.hashtable_EngineGetOver_EngineID[OpName].ToString();
}
DoWhatPlc.CustomeEvetnArgs _e = new DoWhatPlc.CustomeEvetnArgs();
_e.OpName = OpName;
_e.TagValue = m_Value;
//根据请求的命令处理逻辑
switch (m_Command)
{
case "Barcode":
if (m_Value_length > 1) return;
fun_Barcode(_e);
break;
case "ConfirmOkGo"://合格放行
//删除不合格放行记录
//修改托盘状态
//Update_PalletStatus(OpName, 1, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_ConfirmOkGo(OpName, true);
MIS_BASE.Write_FalseGO(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
break;
case "FalseGO"://返修放行
//修改托盘状态
//Update_PalletStatus(OpName, 3, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "NgGO"://不合格放行
//修改托盘状态
//Update_PalletStatus(OpName, 2, false);
//保存不合格信息(必须保存不合格放行信息由于B5A的Moby没有不合格标志位)
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Insert(OpName, engineID, "", "");
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
Thread.Sleep(1000);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "OnLineState"://在线0、离线1、屏蔽2
try
{
if (m_Value_length > 1) return;
int a = Convert.ToInt32(m_Value);
if (a <= 2)
{
BaseDataSystemMES.IsOnLine_Update(OpName, m_Value.ToString());
MIS_BASE.Write_OnLineState(OpName, Convert.ToInt32(m_Value));
if (a == 2) SendMessage.AsyncSendMessage_Notice(OpName, "屏蔽MES");
if (a == 0) SendMessage.AsyncSendMessage_Notice(OpName, "启用MES");
}
}
catch
{
}
break;
case "Reset"://复位将MES所有的信息都复位了
SetMoby(OpName);//将MES所有信号清空
break;
case "TurnLineWork"://150工位独有转线上线标志
SendMessage.AsyncSendMessage_Notice(OpName, "切换成功!");
if (Convert.ToInt32(m_Value) == 1) //(0 正常工件 ,1 转线工件)
{
//写入转线标识点 (64)501.6
MIS_BASE.WritePLC(64, OpName, true);
}
else
{
MIS_BASE.WritePLC(64, OpName, false);
}
break;
case "FixAllow"://重新拧紧
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_FixAllow(OpName, true);
break;
case "IsAutoGetEngineID"://自动手动申请编号(线首)
if (m_Value_length > 1) return;
MIS_BASE.Write_IsAutoGetEngineID(OpName, Convert.ToInt32(m_Value));
break;
case "PartPalletGoOver"://空托盘放行
int Is_PartPalletGoOver;
MIS_BASE.Read_PartPalletGoOver(OpName, out Is_PartPalletGoOver);
if (Is_PartPalletGoOver == 1)
{
MIS_BASE.Write_PartPalletGoOver(OpName, 1);
}
else
{
MIS_BASE.Write_PartPalletGoOver(OpName,0);
}
break;
case "SetMoby"://清空托盘(线首)
SetMoby(OpName);//将MES所有信号清空
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "RepairUplineMES"://返修上线
MIS_BASE.Write_RepairUpline_MES(OpName, true);
break;
case "CancelRepair"://将返修件置为正常件
break;
case "PartPalletCode"://申请写入托盘号
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "WritePartPalletCode"://写入托盘号
if (m_Value_length > 1) return;
MIS_BASE.Write_PalletCode(OpName, Convert.ToInt32(m_Value));
break;
case "Normal"://启用正常拧紧工位
MIS_BASE.Write_Normal(OpName, 1);
MIS_BASE.Write_UnNormal(OpName, 0);
break;
case "UnNormal"://启用备用拧紧工位
MIS_BASE.Write_Normal(OpName, 0);
MIS_BASE.Write_UnNormal(OpName, 1);
break;
case "ResetDevice"://复位设备
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
break;
case "IsNeedRepaire"://返修上线(返修上线点)
if (Convert.ToInt32(m_Value) == 1)
{
//修改托盘状态
MIS_BASE.Write_PalletInfo(OpName, 3);
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
IsNeedRepaire_OK(OpName);
}
else if (Convert.ToInt32(m_Value) == 0)
{
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
//直接给出工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
else
{ }
break;
case "ContinueMatch":
BaseDataSystemMES.QualityVerifyStatus_Hash_Write(OpName, true);
break;
//初始化网页信号
case "IniSingalToWeb":
InitializeSingalToWeb(OpName);
break;
case "Reset_Engine"://返修上线(返修上线点)
SetMoby(OpName);//将MES所有信号清空
//fun_EngineTypeGetOverPLC(OpName, 0);
//fun_EngineTypeGetOverPLC(OpName, 1);
break;
default: break;
}
}
catch(Exception err)
{
////ApplicationLog.WriteLog(err, "Function02:WebSubmit");
}
}
private void SetMoby(string OpName)
{
try
{
//清空Moby时需要将MES信号清空
MIS_BASE.Write_ClearMesMoby(OpName);
BaseDataSystemMES.MesServer_Process_EngineTypeOver(OpName);
Sendmessage("5123", "1111", OpName);
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
}
catch
{
}
}
/// 网页重现登录,恢复关闭前的页面状态
/// </summary>
/// <param name="Opname">工位号</param>
private void InitializeSingalToWeb(string Opname)
{
try
{
//工件到位 DBX0.1
bool S_WorkStart;
bool S_FixAllow;
bool S_EngineGetOver;
bool S_MaterialVerifyOver;
MIS_BASE.Read_WorkStart(Opname, out S_WorkStart);
MIS_BASE.Read_FixAllow(Opname, out S_FixAllow);
MIS_BASE.Read_EngineGetOver_PLC(Opname, out S_EngineGetOver);
MIS_BASE.Read_MaterialVerifyOver(Opname, out S_MaterialVerifyOver);
Sendmessage("13", "1111", Opname);
string S_plcStatus;//DBX501.5 PLC直通1 强制放行 0 正常循环
// 新增查询PLC直通状态 网页显示
MIS_BASE.Read_TagTypeID(63, Opname, out S_plcStatus);
if (S_plcStatus.ToLower() == "false")
{
SendMessageFun.SendInfomation("PlcStatus", "0", Opname);
}
else
{
SendMessageFun.SendInfomation("PlcStatus", "1", Opname);
}
if (S_WorkStart == true)
{
SendInfomation("WorkStart", Convert.ToString(Convert.ToInt32(S_WorkStart)), Opname);
}
if (S_EngineGetOver == true)
{
SendInfomation("EngineTypeGetOverPLC", Convert.ToString(Convert.ToInt32(S_EngineGetOver)), Opname);
Sendmessage("2", "1111", Opname);
SendMessage.ShowMoby(Opname);
}
if (S_FixAllow == true)
{
SendInfomation("FixAllow", Convert.ToString(Convert.ToInt32(S_FixAllow)), Opname);
}
if (S_MaterialVerifyOver == true)
{
SendInfomation("MaterialVerifyOver", Convert.ToString(Convert.ToInt32(S_MaterialVerifyOver)), Opname);
}
InitAlarm(Opname);
}
catch (Exception err)
{
}
}
private void InitAlarm(string Opname)
{
FuntionMesRead.Alarm_InitAlarm_Send(Opname, out Hashtable ht);
foreach (DictionaryEntry kv in ht)
{
var TagID = kv.Key.ToString();
var TagValue = kv.Value.ToString();
FuntionMesRead.Send_AlarmMsg(TagID, TagValue);
}
}
}
}