init: 导入项目到 meswork Gitea

This commit is contained in:
XingCheng3
2026-05-29 10:07:05 +08:00
commit ad9a4106fb
3582 changed files with 460312 additions and 0 deletions

View File

@@ -0,0 +1,276 @@
using System;
using System.Data;
using bizFacade;
using MesServerWork;
namespace MesServerFunctions
{
partial class Functions_BASE_30
{
///// <summary>
///// 分线上总线的数量
///// </summary>
//public static int SubLineLoadPartCount_SubLine = 2;
///// <summary>
///// 分线上总线已经匹配的数量
///// </summary>
//public static int SubLineLoadPartCountMatch_SubLine = 0;
/// <summary>
/// 正常逻辑工作
/// </summary>
/// <param name="OpName"></param>
/// <param name="EngineTypeID"></param>
/// <param name="EngineType"></param>
/// <param name="EngineID"></param>
/// <param name="PartPallet_Code"></param>
private void EngineTypeGetOver_PLC_Work_SubLine(string SubOpName, int SubEngineTypeID, string SubEngineType, string SubEngineID, int SubPartPallet_Code,string OrderForm)
{
int MES_QualityMask = 1;
int IsrepairBarcode = 0;//拆解返修标志
string OpName = "";
//string OrderForm = "";//订单号
string repairBarcode = "";//拆解返修条码
DataTable dt;//读取订单信息
BaseDataSystemMES.GetEngineID_Select(SubOpName, SubEngineID, out dt);
if (dt != null)
{
if (dt.Rows.Count > 0)
{
//OrderForm = Convert.ToString(dt.Rows[0]["订单号"]);
IsrepairBarcode = Convert.ToInt32(dt.Rows[0]["拆解标志"]);
repairBarcode = Convert.ToString(dt.Rows[0]["拆解返修条码"]);
}
}
//第一步,系统记录到位工件信息,发送总线WEB显示
BaseDataSystemMES.OpName_MIS_MOBY_Insert(SubOpName, OrderForm,SubEngineTypeID, SubEngineType, SubEngineID, SubPartPallet_Code, 0, IsrepairBarcode, repairBarcode);
if (MIS_BASE.hashtable_OpNameRepair == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(SubOpName))//获取总工位号
{
OpName = MIS_BASE.hashtable_OpNameRepair[SubOpName].ToString();
}
if (OpName == "")
{
return;
}
SaveMobyMessage(OpName, SubEngineTypeID, SubEngineType, SubEngineID, OrderForm);
SendInfomation("ShowMobySubLine", SubOpName, OpName);
//第二步,判断分线合格标志
MIS_BASE.Read_PalletInfo(SubOpName, out MES_QualityMask);
SendInfomation("SubQualityMask", Convert.ToString(MES_QualityMask), OpName);//将分线合格标志发送到Web页面进行显示
if (MES_QualityMask != 1)
if (MES_QualityMask != 1)
{
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
SendInfomation("NgGO", "1", SubOpName);//显示不合格标志
return;
}
//第三步,匹配
Match_SubLine(SubOpName, SubEngineID, SubEngineTypeID, SubEngineType);//匹配
}
///// <summary>
///// 保存MOBY信息
///// </summary>
///// <param name="OpName"></param>
///// <param name="engineTypeID"></param>
///// <param name="engineType"></param>
///// <param name="engineID"></param>
//private void SaveMobyMessage(string OpName, int engineTypeID, string engineType, string engineID, string orderForm)
//{
// if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
// {
// MIS_BASE.InitHashtable_MesServerCode();
// }
// if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID.ContainsKey(OpName))
// {
// MIS_BASE.hashtable_EngineGetOver_EngineTypeID[OpName] = engineTypeID;
// }
// if (MIS_BASE.hashtable_EngineGetOver_EngineType.ContainsKey(OpName))
// {
// MIS_BASE.hashtable_EngineGetOver_EngineType[OpName] = engineType;
// }
// if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName))
// {
// MIS_BASE.hashtable_EngineGetOver_EngineID[OpName] = engineID;
// }
// if (MIS_BASE.hashtable_EngineGetOver_OrderForm.ContainsKey(OpName))
// {
// MIS_BASE.hashtable_EngineGetOver_OrderForm[OpName] = orderForm;
// }
//}
/// <summary>
/// 正常匹配分线和总线
/// </summary>
/// <param name="opName"></param>
/// <param name="engineID">分线工件号</param>
/// <param name="engineTypeID">分线工件机型代码</param>
/// <param name="engineType">分线工件机型</param>
private void Match_SubLine(string opName_SubLine, string engineID_SubLine, int engineTypeID_SubLine, string engineType_SubLine)
{
try
{
bool m_EngineGetOver_PLC;
int engineTypeID;
int partPallet_Code;
int PalletInfo = 1;//分线合格标志
string opName = "";//总线工件信息
string engineID;
string engineType;
string AlarmStr;
if (MIS_BASE.hashtable_OpNameRepair == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
//读取总线信息(工位号 传递机型 合格标志)
if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(opName_SubLine))//获取总工位号
{
opName = MIS_BASE.hashtable_OpNameRepair[opName_SubLine].ToString();
}
if (opName == "")
{
return;
}
MIS_BASE.Read_EngineGetOver_PLC(opName, out m_EngineGetOver_PLC);//1:读取总线工件到位的传递机型信号。
if (!m_EngineGetOver_PLC) return;//必须工件同时到位才能进行匹配
//判断分线数据是否合格
//if (!BaseDataSystemMES.QulityDataVerify(opName, engineID_SubLine, out AlarmStr) && !BaseDataSystemMES.QualityVerifyStatus_Hash_Read(opName))
//{
// SendInfomation("LineoutAlert", AlarmStr, opName);
// return;
//}
//MIS_BASE.Read_PalletInfo(opName, out PalletInfo);//总线合格标识
//if (PalletInfo != 1) return;//总线不合格时,由人工确认强制匹配
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(opName, out engineTypeID, out engineType, out engineID, out partPallet_Code, out OrderForm);//获取总线的信息
//if (engineType == engineType_SubLine)
//{
// //分线上总线数据转移
// BaseDataSystemMES.MailLineAndSubLineData_Insert(engineID, engineTypeID, engineType, engineID_SubLine);
// MIS_BASE.Write_Match(opName, true);//匹配结果
// MIS_BASE.Write_MatchingCompleted(opName, true); //匹配完成
// //发送匹配结果信息
// sendmessage(opName, 1, "Match");//匹配结果
// SendInfomation("MatchSuccess", "1", opName);//界面显示匹配成功
// //BaseDataSystemMES.SubLineLoadPartCountMatch_Select(opName, out SubLineLoadPartCountMatch);
// SubLineLoadPartCountMatch = SubLineLoadPartCountMatch + 1;
// // BaseDataSystemMES.SubLineLoadPartCountMatch_Update(opName, SubLineLoadPartCountMatch);
// if (SubLineLoadPartCountMatch== SubLineLoadPartCount)
// {
// MIS_BASE.Write_FixAllow(opName, true);//允许PLC工作
// SubLineLoadPartCountMatch = 0;
// BaseDataSystemMES.SubLineLoadPartCountMatch_Update(opName, SubLineLoadPartCountMatch);
// }
//}
//else
//{
// MIS_BASE.Write_Match(opName, false);//匹配结果
// MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成
// AsyncSendMessage_Notice(opName, "机型匹配失败");
// SendInfomation("MatchSuccess", "0", opName);//界面显示匹配失败
// sendmessage(opName, 0, "Match");//匹配结果
//}
}
catch
{
}
}
///// <summary>
///// 强制匹配分线和总线
///// </summary>
///// <param name="opName"></param>
//private void ForceMatch(string opName)
//{
// try
// {
// bool m_EngineGetOver_PLC_SubLine;
// bool m_EngineGetOver_PLC;
// int engineTypeID_SubLine;
// int engineTypeID;
// int partPallet_Code_SubLine;
// int partPallet_Code;
// string opName_SubLine = "";//分线工件信息
// string engineID_SubLine;
// string engineType_SubLine;
// string engineID;
// string engineType;
// if (MIS_BASE.hashtable_OpNameRepair == null)
// {
// MIS_BASE.InitHashtable_MesServerCode();
// }
// //获取分线中间交互工位号
// if (MIS_BASE.hashtable_OpNameRepair.ContainsKey(opName))
// {
// opName_SubLine = MIS_BASE.hashtable_OpNameRepair[opName].ToString();
// }
// if (opName_SubLine == "")
// {
// return;
// }
// MIS_BASE.Read_EngineGetOver_PLC(opName_SubLine, out m_EngineGetOver_PLC_SubLine);//1:读取分线工件到位的传递机型信号。
// if (!m_EngineGetOver_PLC_SubLine) return;//必须工件同时到位才能进行匹配
// MIS_BASE.Read_EngineGetOver_PLC(opName, out m_EngineGetOver_PLC);//2:读取总线工件到位的传递机型信号。
// if (!m_EngineGetOver_PLC) return;//必须工件同时到位才能进行匹配
// MIS_BASE.GetEngineTypeFromPLC(opName_SubLine, out engineTypeID_SubLine, out engineType_SubLine, out engineID_SubLine, out partPallet_Code_SubLine);//获取分线的信息
// MIS_BASE.GetEngineTypeFromPLC(opName, out engineTypeID, out engineType, out engineID, out partPallet_Code);
// BaseDataSystemMES.MailLineAndSubLineData_Insert(engineID, engineTypeID, engineType, engineID_SubLine);//分线上总线数据转移
// MIS_BASE.Write_Match(opName, true);//匹配结果
// MIS_BASE.Write_MatchingCompleted(opName, true);//匹配完成
// SendInfomation("MatchSuccess", "1", opName);//界面显示匹配成功
// MIS_BASE.Write_FixAllow(opName, true);//允许PLC工作
// //发送匹配完成和匹配结果信息
// sendmessage(opName, 1, "MatchingComplete");//匹配完成
// sendmessage(opName, 1, "Match");//匹配结果
// }
// catch
// {
// }
//}
}
}