init: 导入项目到 meswork Gitea

This commit is contained in:
XingCheng3
2026-05-29 10:07:05 +08:00
commit ad9a4106fb
3582 changed files with 460312 additions and 0 deletions

View File

@@ -0,0 +1,72 @@
using System;
//using SystemFramework;
using MesServerWork;
using System.Data;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
///第一步,判断条码类型,根据条码类型,执行对应的存储过程
///第二步,条码类型(将扫描的条码保存到对应的表中)
///第三步,扫描完成之后给出允许工作信号
/// 处理页面扫描条码
/// </summary>
/// <param name="OpName"></param>
/// <param name="barcode"></param>
public void AllowRepair(string OpName, string barcode, string RepairMethod)
{
try
{
SelectEngineIDByBarcode(OpName, barcode);
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:AllowRepair");
}
}
/// <summary>
/// 写入返修信息
/// </summary>
/// <param name="OpName"></param>
private void SelectEngineIDByBarcode(string OpName, string barcode)
{
string EngineType = "";
int EngineTypeID = 0;
int linepath = 0;
string AllRepairstate = "";
DataTable dt;
//获取订单号,发动机型号,发动机型号代码(在线首工位将选择的订单,机型等信息保存到监控表中)
GetEngineID_RepairSelect(barcode, out dt);
EngineTypeID = Convert.ToInt32(dt.Rows[0]["机型代码"].ToString());
EngineType = dt.Rows[0]["发动机型号"].ToString();
linepath = Convert.ToInt32(dt.Rows[0]["上线路径"].ToString());
AllRepairstate = dt.Rows[0]["返修状态字符串"].ToString();
MIS_BASE.Write_EngineTypeID_MES(OpName, EngineTypeID);
MIS_BASE.Write_EngineType_MES(OpName, EngineType);
MIS_BASE.Write_EngineID_MES(OpName, barcode);
MIS_BASE.Write_RepairStatusMES(OpName, linepath);
MIS_BASE.Write_RepairPathString(OpName, AllRepairstate);
//获取订单号,发动机型号,发动机型号代码(在线首工位将选择的订单,机型等信息保存到监控表中)
bizFacade.BaseDataSystemMES.OpName_MIS_CreateMoby_Select(OpName, out string orderForm, out int engineTypeID, out string engineType, out string engineID, out string palletCode, out int isRepair, out string repairCode);
MIS_BASE.Write_OrderForm_MES(OpName, orderForm);
//SendInfomation("ShowMobyMES", barcode + "&" + EngineType, OpName);
//MES传递机型
MIS_BASE.Write_EngineTypeGetOver_MES(OpName, true);
}
}
}

View File

@@ -0,0 +1,59 @@
using System;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
///扫描物料条码或批次号
/// </summary>
/// <param name="OpName"></param>
/// <param name="barcode"></param>
public void Barcode(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
string QRcode = Convert.ToString(msgEvent.TagValue);
string barcode = "";
string EngineType = "";
bool ispartload = false;
bool select_OK = false;
MIS_BASE.Read_PartLoad(OpName, out ispartload);
if (!ispartload)
{
AsyncSendMessage_Notice(OpName, "PLC未申请上线,请确认");
return;
}
//判断是否是返修上线条码
select_OK = SelectRepairBarcode(OpName, QRcode, out barcode, out EngineType);
if (barcode.Length < 5 || !select_OK)
{
AsyncSendMessage_Notice(OpName, "条码无效,请确认");
return;
}
else
{
//显示该总成各个工位的质量数据
SendInfomation("RepairQuality", barcode, OpName);
//向前端发送查询后的barcode
SendInfomation("SelectBarcode", barcode, OpName);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:Barcode");
}
}
}
}

View File

@@ -0,0 +1,36 @@
using System;
using bizFacade;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
/// 合格放行
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void ConfirmOkGo(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
//工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:ConfirmOkGo");
}
}
}
}

View File

@@ -0,0 +1,43 @@
using System;
//using SystemFramework;
using MesServerWork;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
/// PLC传递机型处理
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void EngineTypeGetOver_PLC(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
int EngineTypeID;//机型代码
int PartPallet_Code;//托盘编号
string EngineType;//机型
string EngineID;//工件编号
string OrderForm;
MIS_BASE.GetEngineTypeFromPLC(OpName, out EngineTypeID, out EngineType, out EngineID, out PartPallet_Code, out OrderForm );
EngineTypeGetOver_PLC_Work(OpName, EngineTypeID, EngineType, EngineID, PartPallet_Code,OrderForm);
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:EngineTypeGetOver_PLC");
}
}
}
}

View File

@@ -0,0 +1,35 @@
using System;
//using SystemFramework;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
/// 申请上线
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void PartLoad(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
if (tagValue == 1)
{
AsyncSendMessage_Notice(OpName, "请扫描返修件条码!");
}
}
catch (Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:PartLoad");
}
}
}
}

View File

@@ -0,0 +1,250 @@
using System;
using MesServerWork;
using bizFacade;
//using SystemFramework;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
/// 处理WEB页面发送过来的请求m_Command + "|" + m_Value;
/// </summary>
/// <param name="OpName"></param>
/// <param name="Content"></param>
private void WebSubmit(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
string Content = Convert.ToString(msgEvent.TagValue);
string[] dataArray = Content.Split('|');
if (dataArray.Length != 2)
return;
//消息类型
string m_Command = dataArray[0].ToString();
//消息参数
string m_Value = dataArray[1].ToString();
//消息参数数量
string[] m_Value_array = m_Value.Split('&');
//消息参数长度
int m_Value_length = m_Value_array.Length;
//工件信息
string engineID = "";
if (MIS_BASE.hashtable_EngineGetOver_EngineTypeID == null)
{
MIS_BASE.InitHashtable_MesServerCode();
}
if (MIS_BASE.hashtable_EngineGetOver_EngineID.ContainsKey(OpName))
{
engineID = MIS_BASE.hashtable_EngineGetOver_EngineID[OpName].ToString();
}
DoWhatPlc.CustomeEvetnArgs _e = new DoWhatPlc.CustomeEvetnArgs();
_e.OpName = OpName;
_e.TagValue = m_Value;
//根据请求的命令处理逻辑
switch (m_Command)
{
case "Barcode":
if (m_Value_length > 1) return;
fun_Barcode(_e);
break;
case "ConfirmOkGo"://合格放行
//删除不合格放行记录
//修改托盘状态
//Update_PalletStatus(OpName, 1, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_ConfirmOkGo(OpName, true);
MIS_BASE.Write_FalseGO(OpName, false);
break;
case "FalseGO"://返修放行
//修改托盘状态
//Update_PalletStatus(OpName, 3, false);
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Delete(OpName, engineID);
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
break;
case "NgGO"://不合格放行
//修改托盘状态
//Update_PalletStatus(OpName, 2, false);
//保存不合格信息(必须保存不合格放行信息由于B5A的Moby没有不合格标志位)
BaseDataSystemMES.BaseData_tagTable_Engine_IsNG_Insert(OpName, engineID, "", "");
MIS_BASE.Write_FalseGO(OpName, true);
MIS_BASE.Write_ConfirmOkGo(OpName, false);
break;
case "OnLineState"://在线0、离线1、屏蔽2
try
{
if (m_Value_length > 1) return;
int a = Convert.ToInt32(m_Value);
if (a <= 2)
{
BaseDataSystemMES.IsOnLine_Update(OpName, m_Value.ToString());
MIS_BASE.Write_OnLineState(OpName, Convert.ToInt32(m_Value));
}
}
catch
{
}
break;
case "Reset"://复位将MES所有的信息都复位了
SetMoby(OpName);//将MES所有信号清空
break;
case "FixAllow"://重新拧紧
MIS_BASE.Write_FixAllow(OpName, false);
MIS_BASE.Write_FixAllow(OpName, true);
break;
case "IsAutoGetEngineID"://自动手动申请编号(线首)
if (m_Value_length > 1) return;
MIS_BASE.Write_IsAutoGetEngineID(OpName, Convert.ToInt32(m_Value));
break;
case "PartPalletGoOver"://空托盘放行
int Is_PartPalletGoOver;
MIS_BASE.Read_PartPalletGoOver(OpName, out Is_PartPalletGoOver);
if (Is_PartPalletGoOver == 1)
{
MIS_BASE.Write_PartPalletGoOver(OpName, 1);
}
else
{
MIS_BASE.Write_PartPalletGoOver(OpName,0);
}
break;
case "SetMoby"://清空托盘(线首)
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "RepairUplineMES"://返修上线
MIS_BASE.Write_RepairUpline_MES(OpName, true);
break;
case "CancelRepair"://将返修件置为正常件
break;
case "PartPalletCode"://申请写入托盘号
//MIS_BASE.Write_PartPalletCode_PLC(OpName, 1);
break;
case "WritePartPalletCode"://写入托盘号
if (m_Value_length > 1) return;
MIS_BASE.Write_PalletCode(OpName, Convert.ToInt32(m_Value));
break;
case "Normal"://启用正常拧紧工位
MIS_BASE.Write_Normal(OpName, 1);
MIS_BASE.Write_UnNormal(OpName, 0);
break;
case "UnNormal"://启用备用拧紧工位
MIS_BASE.Write_Normal(OpName, 0);
MIS_BASE.Write_UnNormal(OpName, 1);
break;
case "ResetDevice"://复位设备
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
break;
case "IsNeedRepaire"://返修上线(返修上线点)
if (Convert.ToInt32(m_Value) == 1)
{
//修改托盘状态
MIS_BASE.Write_PalletInfo(OpName, 3);
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
IsNeedRepaire_OK(OpName);
}
else if (Convert.ToInt32(m_Value) == 0)
{
//通知修改成功
MIS_BASE.Write_UpdatePalletOK(OpName, true);
//直接给出工作完成
MIS_BASE.Write_MaterialVerifyOver(OpName, true);
}
else
{ }
break;
case "RepairMarks":
string[] value = m_Value.Split('/');
string barcode = value[0];
string RepairMethod = value[1];
AllowRepair(OpName, barcode, RepairMethod);
break;
//初始化网页信号
case "IniSingalToWeb":
InitializeSingalToWeb(OpName);
break;
case "Reset_Engine"://返修上线(返修上线点)
SetMoby(OpName);//将MES所有信号清空
break;
default: break;
}
}
catch(Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:WebSubmit");
}
}
private void SetMoby(string OpName)
{
try
{
//清空Moby时需要将MES信号清空
MIS_BASE.Write_ClearMesMoby(OpName);
BaseDataSystemMES.MesServer_Process_EngineTypeOver(OpName);
Sendmessage("5123", "1111", OpName);
MIS_BASE.Write_ResetDevice(OpName, true);
System.Threading.Thread.Sleep(1000);
MIS_BASE.Write_ResetDevice(OpName, false);
}
catch
{
}
}
/// 网页重现登录,恢复关闭前的页面状态
/// </summary>
/// <param name="Opname">工位号</param>
private void InitializeSingalToWeb(string Opname)
{
//工件到位 DBX0.1
bool S_WorkStart;
bool S_FixAllow;
bool S_EngineGetOver;
bool S_MaterialVerifyOver;
MIS_BASE.Read_WorkStart(Opname, out S_WorkStart);
MIS_BASE.Read_FixAllow(Opname, out S_FixAllow);
MIS_BASE.Read_EngineGetOver_PLC(Opname, out S_EngineGetOver);
MIS_BASE.Read_MaterialVerifyOver(Opname, out S_MaterialVerifyOver);
if (S_WorkStart == true)
{
SendInfomation("WorkStart", Convert.ToString(Convert.ToInt32(S_WorkStart)), Opname);
}
if (S_EngineGetOver == true)
{
SendInfomation("EngineTypeGetOverPLC", Convert.ToString(Convert.ToInt32(S_EngineGetOver)), Opname);
Sendmessage("5123", "1111", Opname);
}
if (S_FixAllow == true)
{
SendInfomation("FixAllow", Convert.ToString(Convert.ToInt32(S_FixAllow)), Opname);
}
if (S_MaterialVerifyOver == true)
{
SendInfomation("MaterialVerifyOver", Convert.ToString(Convert.ToInt32(S_MaterialVerifyOver)), Opname);
}
}
}
}

View File

@@ -0,0 +1,29 @@
using System;
//using SystemFramework;
namespace MesServerFunctions
{
partial class Functions_BASE_07
{
/// <summary>
/// 工件到位与离开时清空MES自身信号
/// </summary>
/// <param name="OpName"></param>
/// <param name="tagValue"></param>
private void WorkStart(object e)
{
try
{
DoWhatPlc.CustomeEvetnArgs msgEvent = (DoWhatPlc.CustomeEvetnArgs)e;
string OpName = Convert.ToString(msgEvent.OpName);
int tagValue = Convert.ToInt32(msgEvent.TagValue);
}
catch(Exception err)
{
////ApplicationLog.WriteLog(err, "Function07:WorkStart");
}
}
}
}